Setup uncertainties and PTV margins at different anatomical levels in intensity modulated radiotherapy for nasopharyngeal cancer.

Milan Anjanappa1, Malu Rafi1, Saju Bhasi2, Rejnish Kumar1, Kainickal Cessal Thommachan1, Tapesh Bhattacharya1, Kunnambath Ramadas1.   

Abstract

AIM: To determine the systematic error (∑), random error (σ) and derive PTV margin at different levels of the target volumes in Nasopharyngeal Cancer (NPC).
MATERIALS AND METHODS: A retrospective offline review was done for patients who underwent IMRT for NPC from June 2015 to May 2016 at our institution. Alternate day kV images were matched with digitally reconstructed radiographs to know the setup errors. All radiographs were matched at three levels - the clivus, third cervical (C3) and sixth cervical (C6) vertebra. The shifts in positions along the vertical, longitudinal and lateral axes were noted and the ∑ and σ at three levels were calculated. PTV margins were derived using van Herk's formula.
RESULTS: Twenty patients and 300 pairs of orthogonal portal films were reviewed. The ∑ for the clivus, C3 and C6 along vertical, longitudinal and lateral directions were 1.6 vs. 1.8 vs. 2 mm; 1.2 vs. 1.4 vs. 1.4 mm and 0.9 vs. 1.6 and 2.3 mm, respectively. Similarly, the random errors were 1.1 vs. 1.4 vs. 1.8 mm; 1.1 vs. 1.2 vs. 1.2 mm and 1.2 vs. 1.3 vs. 1.6 mm. The PTV margin at the clivus was 4.4 mm along the vertical, 4 mm along the longitudinal direction and 3.2 m in the lateral direction. At the C3 level, it was 5.5 mm in the vertical, 5 mm in the lateral direction and 4.4 mm in the longitudinal direction. At the C6 level, it was 6.4 mm in the vertical, 6.9 mm in the lateral direction and 4.4 mm in the longitudinal direction.
CONCLUSION: A differential margin along different levels of target may be necessary to adequately cover the target.

Entities:  

Keywords:  Nasopharyngeal cancer; PTV margin; Setup error

Year:  2017        PMID: 28831279      PMCID: PMC5552104          DOI: 10.1016/j.rpor.2017.07.005

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  16 in total

1.  Margins for translational and rotational uncertainties: a probability-based approach.

Authors:  Peter Remeijer; Coen Rasch; Joos V Lebesque; Marcel van Herk
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-06-01       Impact factor: 7.038

2.  Evaluation of the planning target volume in the treatment of head and neck cancer with intensity-modulated radiotherapy: what is the appropriate expansion margin in the setting of daily image guidance?

Authors:  Allen M Chen; D Gregory Farwell; Quang Luu; Paul J Donald; Julian Perks; James A Purdy
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-10-06       Impact factor: 7.038

3.  Magnitude and clinical relevance of translational and rotational patient setup errors: a cone-beam CT study.

Authors:  Matthias Guckenberger; Juergen Meyer; Dirk Vordermark; Kurt Baier; Juergen Wilbert; Michael Flentje
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-07-01       Impact factor: 7.038

4.  Assessment of residual setup errors for anatomical sub-structures in image-guided head-and-neck cancer radiotherapy.

Authors:  Milos Djordjevic; Emmelie Sjöholm; Owe Tullgren; Bruno Sorcini
Journal:  Acta Oncol       Date:  2013-12-09       Impact factor: 4.089

5.  Variable planning margin approach to account for locoregional variations in setup uncertainties.

Authors:  Jinzhong Yang; Adam S Garden; Yongbin Zhang; Lifei Zhang; Lei Dong
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

6.  Effects of remedies made in patient setup process on residual setup errors and margins in head and neck cancer radiotherapy based on 2D image guidance.

Authors:  Mika Kapanen; Marko Laaksomaa; Tapio Tulijoki; Pirkko-Liisa Kellokumpu-Lehtinen; Simo Hyödynmaa
Journal:  Rep Pract Oncol Radiother       Date:  2015-04-01

7.  Measuring radiotherapy setup errors at multiple neck levels in nasopharyngeal cancer (NPC): A case for differential PTV expansion.

Authors:  Timothy Cheo; Yvonne Loh; Desiree Chen; Khai Mun Lee; Ivan Tham
Journal:  Radiother Oncol       Date:  2015-10-22       Impact factor: 6.280

8.  Comparison of 2D radiographic images and 3D cone beam computed tomography for positioning head-and-neck radiotherapy patients.

Authors:  Heng Li; X Ronald Zhu; Lifei Zhang; Lei Dong; Sam Tung; Anesa Ahamad; K S Clifford Chao; William H Morrison; David I Rosenthal; David L Schwartz; Radhe Mohan; Adam S Garden
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-04-18       Impact factor: 7.038

9.  Daily image guidance with cone-beam computed tomography for head-and-neck cancer intensity-modulated radiotherapy: a prospective study.

Authors:  Robert B Den; Anthony Doemer; Greg Kubicek; Greg Bednarz; James M Galvin; William M Keane; Ying Xiao; Mitchell Machtay
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-06-18       Impact factor: 7.038

10.  Setup uncertainties of anatomical sub-regions in head-and-neck cancer patients after offline CBCT guidance.

Authors:  Simon van Kranen; Suzanne van Beek; Coen Rasch; Marcel van Herk; Jan-Jakob Sonke
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-04-01       Impact factor: 7.038

View more
  4 in total

1.  Estimating PTV Margins in Head and Neck Stereotactic Ablative Radiation Therapy (SABR) Through Target Site Analysis of Positioning and Intrafractional Accuracy.

Authors:  Shane Mesko; He Wang; Samuel Tung; Congjun Wang; Dario Pasalic; Bhavana V Chapman; Amy C Moreno; Jay P Reddy; Adam S Garden; David I Rosenthal; G Brandon Gunn; Steven J Frank; Clifton D Fuller; William Morrison; Jack Phan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2019-09-30       Impact factor: 7.038

2.  Assessment of the therapeutic accuracy of cone beam computed tomography-guided nasopharyngeal carcinoma radiotherapy.

Authors:  Jiabin Liu; Khumbula Maitireazvo Lyman; Zhenhua Ding; Liang Zhou
Journal:  Oncol Lett       Date:  2019-05-30       Impact factor: 2.967

3.  Effectiveness of the No action level protocol for head & neck patients - Time considerations.

Authors:  Pawel Kukolowicz; Monika Mietelska; Dorota Kiprian
Journal:  Rep Pract Oncol Radiother       Date:  2020-04-12

4.  A study of nonuniform CTV to PTV margin expansion incorporating both rotational and translational uncertainties.

Authors:  Junjie Miao; Yingjie Xu; Yuan Tian; Zhiqiang Liu; Jianrong Dai
Journal:  J Appl Clin Med Phys       Date:  2019-12-02       Impact factor: 2.102