Literature DB >> 26603773

Measuring radiotherapy setup errors at multiple neck levels in nasopharyngeal cancer (NPC): A case for differential PTV expansion.

Timothy Cheo1, Yvonne Loh2, Desiree Chen2, Khai Mun Lee3, Ivan Tham2.   

Abstract

BACKGROUND AND
PURPOSE: We aim to quantify the magnitude of the systematic and random setup errors at three different anatomical levels of the neck in Nasopharyngeal Carcinoma (NPC) when clivus matching is used, and recommend appropriate PTV margins for each level.
MATERIAL AND METHODS: Thirty-six patients undergoing image-guided radiotherapy (IGRT) each with 9 scheduled CBCTs were reviewed. The magnitude of setup errors were measured at the level of the clivus, C4 and C7 vertebrae, before and after CBCT correction. The 3D displacements, systematic and random errors were calculated for each level. The appropriate PTV expansion was determined using Van Herk's formula.
RESULTS: Mean 3D displacement was 1.88, 2.66 and 3.35 mm at the clivus, C4 and C7 before correction. The differences were statistically significant (p<0.05). The PTV margin required without correction was 2.33, 4.33 and 6.52 mm respectively. These were reduced to 1.20, 3.72 and 6.08 mm after CBCT corrections.
CONCLUSIONS: Variability is seen in setup errors at the clivus, C4 and C7 vertebral levels. A variable planning margin approach with reduced margin at the clivus is recommended. Use of daily CBCT allows the PTV expansion to be reduced to 1.2 mm.
Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Nasopharyngeal Carcinoma; PTV margin; Setup errors

Mesh:

Year:  2015        PMID: 26603773     DOI: 10.1016/j.radonc.2015.09.032

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  7 in total

1.  Setup uncertainties and PTV margins at different anatomical levels in intensity modulated radiotherapy for nasopharyngeal cancer.

Authors:  Milan Anjanappa; Malu Rafi; Saju Bhasi; Rejnish Kumar; Kainickal Cessal Thommachan; Tapesh Bhattacharya; Kunnambath Ramadas
Journal:  Rep Pract Oncol Radiother       Date:  2017-08-08

2.  Estimating PTV Margins in Head and Neck Stereotactic Ablative Radiation Therapy (SABR) Through Target Site Analysis of Positioning and Intrafractional Accuracy.

Authors:  Shane Mesko; He Wang; Samuel Tung; Congjun Wang; Dario Pasalic; Bhavana V Chapman; Amy C Moreno; Jay P Reddy; Adam S Garden; David I Rosenthal; G Brandon Gunn; Steven J Frank; Clifton D Fuller; William Morrison; Jack Phan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2019-09-30       Impact factor: 7.038

3.  Analysis of geometric variation of neck node levels during image-guided radiotherapy for nasopharyngeal carcinoma: recommended planning margins.

Authors:  Wenyong Tan; Yingjie Wang; Ming Yang; Richard A Amos; Weihao Li; Jianzeng Ye; Royle Gary; Weixi Shen; Desheng Hu
Journal:  Quant Imaging Med Surg       Date:  2018-08

4.  Automated algorithm for calculation of setup corrections and planning target volume margins for offline image-guided radiotherapy protocols.

Authors:  Auwal Abubakar; Nada Alia M Zamri; Shazril Imran Shaukat; Hafiz Mohd Zin
Journal:  J Appl Clin Med Phys       Date:  2021-06-09       Impact factor: 2.102

5.  3D-Printed masks as a new approach for immobilization in radiotherapy - a study of positioning accuracy.

Authors:  Matthias Felix Haefner; Frederik Lars Giesel; Matthias Mattke; Daniel Rath; Moritz Wade; Jacob Kuypers; Alan Preuss; Hans-Ulrich Kauczor; Jens-Peter Schenk; Juergen Debus; Florian Sterzing; Roland Unterhinninghofen
Journal:  Oncotarget       Date:  2018-01-08

6.  Assessment of the therapeutic accuracy of cone beam computed tomography-guided nasopharyngeal carcinoma radiotherapy.

Authors:  Jiabin Liu; Khumbula Maitireazvo Lyman; Zhenhua Ding; Liang Zhou
Journal:  Oncol Lett       Date:  2019-05-30       Impact factor: 2.967

7.  Radiotherapy-Compatible Robotic System for Multi-Landmark Positioning in Head and Neck Cancer Treatments.

Authors:  Mark Ostyn; Siqiu Wang; Yun-Soung Kim; Siyong Kim; Woon-Hong Yeo
Journal:  Sci Rep       Date:  2019-10-07       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.