Literature DB >> 18395358

Comparison of 2D radiographic images and 3D cone beam computed tomography for positioning head-and-neck radiotherapy patients.

Heng Li1, X Ronald Zhu, Lifei Zhang, Lei Dong, Sam Tung, Anesa Ahamad, K S Clifford Chao, William H Morrison, David I Rosenthal, David L Schwartz, Radhe Mohan, Adam S Garden.   

Abstract

PURPOSE: To assess the positioning accuracy using two-dimensional kilovoltage (2DkV) imaging and three-dimensional cone beam CT (CBCT) in patients with head and neck (H&N) cancer receiving radiation therapy. To assess the benefit of patient-specific headrest.
MATERIALS AND METHODS: All 21 patients studied were immobilized using thermoplastic masks with either a patient-specific vacuum bag (11 of 21, IMA) or standard clear plastic (10 of 21, IMB) headrests. Each patient was imaged with a pair of orthogonal 2DkV images in treatment position using onboard imaging before the CBCT procedure. The 2DkV and CBCT images were acquired weekly during the same session. The 2DkV images were reviewed by oncologists and also analyzed by a software tool based on mutual information (MI).
RESULTS: Ninety-eight pairs of assessable 2DkV-CBCT alignment sets were obtained. Systematic and random errors were <1.6 mm for both 2DkV and CBCT alignments. When we compared shifts determined by CBCT and 2DkV for the same patient setup, statistically significant correlations were observed in all three major directions. Among all CBCT couch shifts, 4.1% > or = 0.5 cm and 18.7% > or = 0.3 cm, whereas among all 2DkV (MI) shifts, 1.7% > or = 0.5 cm and 11.2% > or = 0.3 cm. Statistically significant difference was found on anteroposterior direction between IMA and IMB with the CBCT alignment only.
CONCLUSIONS: The differences between 2D and 3D alignments were mainly caused by the relative flexibility of certain H&N structures and possibly by rotation. Better immobilization of the flexible neck is required to further reduce the setup errors for H&N patients receiving radiotherapy.

Entities:  

Mesh:

Year:  2008        PMID: 18395358     DOI: 10.1016/j.ijrobp.2008.01.008

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  38 in total

Review 1.  Current progress in adaptive radiation therapy for head and neck cancer.

Authors:  David L Schwartz
Journal:  Curr Oncol Rep       Date:  2012-04       Impact factor: 5.075

2.  Use of planar kV vs. CBCT in evaluation of setup errors in oesophagus carcinoma radiotherapy.

Authors:  Liliana Martins; Jose Guilherme Couto; Barbara Barbosa
Journal:  Rep Pract Oncol Radiother       Date:  2015-11-14

Review 3.  kV cone-beam CT-based IGRT: a clinical review.

Authors:  Judit Boda-Heggemann; Frank Lohr; Frederik Wenz; Michael Flentje; Matthias Guckenberger
Journal:  Strahlenther Onkol       Date:  2011-04-26       Impact factor: 3.621

4.  Automatic fusion of lateral cephalograms and digital volume tomography data-perspective for combining two modalities in the future.

Authors:  S Sauppe; C Abkai; J Hourfar; B Ludwig; J Ulrici; E Hell
Journal:  Dentomaxillofac Radiol       Date:  2015-07-24       Impact factor: 2.419

5.  Multi-system verification of registrations for image-guided radiotherapy in clinical trials.

Authors:  Yunfeng Cui; James M Galvin; William L Straube; Walter R Bosch; James A Purdy; X Allen Li; Ying Xiao
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-01-13       Impact factor: 7.038

6.  Adaptive radiation therapy for head and neck cancer-can an old goal evolve into a new standard?

Authors:  David L Schwartz; Lei Dong
Journal:  J Oncol       Date:  2010-08-18       Impact factor: 4.375

7.  Accurate positioning for head and neck cancer patients using 2D and 3D image guidance.

Authors:  Hyejoo Kang; Dale M Lovelock; Ellen D Yorke; Sergey Kriminski; Nancy Lee; Howard I Amols
Journal:  J Appl Clin Med Phys       Date:  2010-10-27       Impact factor: 2.102

8.  Method comparison of automated matching software-assisted cone-beam CT and stereoscopic kilovoltage x-ray positional verification image-guided radiation therapy for head and neck cancer: a prospective analysis.

Authors:  Clifton D Fuller; Todd J Scarbrough; Jan-Jakob Sonke; Coen R N Rasch; Mehee Choi; Joe Y Ting; Samuel J Wang; Niko Papanikolaou; David I Rosenthal
Journal:  Phys Med Biol       Date:  2009-11-24       Impact factor: 3.609

9.  A prospective analysis of inter- and intrafractional errors to calculate CTV to PTV margins in head and neck patients.

Authors:  J Cacicedo; J F Perez; R Ortiz de Zarate; O del Hoyo; F Casquero; A Gómez-Iturriaga; A Lasso; E Boveda; P Bilbao
Journal:  Clin Transl Oncol       Date:  2014-07-19       Impact factor: 3.405

10.  Recent advances in image-guided radiotherapy for head and neck carcinoma.

Authors:  Sameer K Nath; Daniel R Simpson; Brent S Rose; Ajay P Sandhu
Journal:  J Oncol       Date:  2009-07-29       Impact factor: 4.375

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.