An approach for balancing diagnostic image quality with cancer risk: application to pediatric diagnostic imaging of 99mTc-dimercaptosuccinic acid.

George Sgouros1, Eric C Frey, Wesley E Bolch, Michael B Wayson, Andres F Abadia, S Ted Treves.   

Abstract

UNLABELLED: A recent survey of pediatric hospitals showed a large variability in the activity administered for diagnostic nuclear medicine imaging of children. Imaging guidelines, especially for pediatric patients, must balance the risks associated with radiation exposure with the need to obtain the high-quality images necessary to derive the benefits of an accurate clinical diagnosis.
METHODS: Pharmacokinetic modeling and a pediatric series of nonuniform rational B-spline-based phantoms have been used to simulate (99m)Tc-dimercaptosuccinic acid SPECT images. Images were generated for several different administered activities and for several lesions with different target-to-background activity concentration ratios; the phantoms were also used to calculate organ S values for (99m)Tc. Channelized Hotelling observer methodology was used in a receiver-operating-characteristic analysis of the diagnostic quality of images with different modeled administered activities (i.e., count densities) for anthropomorphic reference phantoms representing two 10-y-old girls with equal weights but different body morphometry. S value-based dosimetry was used to calculate the mean organ-absorbed doses to the 2 pediatric patients. Using BEIR VII age- and sex-specific risk factors, we converted absorbed doses to excess risk of cancer incidence and used them to directly assess the risk of the procedure.
RESULTS: Combined, these data provided information about the tradeoff between cancer risk and diagnostic image quality for 2 phantoms having the same weight but different body morphometry. The tradeoff was different for the 2 phantoms, illustrating that weight alone may not be sufficient for optimally scaling administered activity in pediatric patients.
CONCLUSION: The study illustrates implementation of a rigorous approach for balancing the benefits of adequate image quality against the radiation risks and also demonstrates that weight-based adjustment to the administered activity is suboptimal. Extension of this methodology to other radiopharmaceuticals would yield the data required to generate objective and well-founded administered activity guidelines for pediatric and other patients.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22144506      PMCID: PMC3290866          DOI: 10.2967/jnumed.111.092221

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  19 in total

1.  Optimum compensation method and filter cutoff frequency in myocardial SPECT: a human observer study.

Authors:  Sharlini Sankaran; Eric C Frey; Karen L Gilland; Benjamin M W Tsui
Journal:  J Nucl Med       Date:  2002-03       Impact factor: 10.057

2.  Application of task-based measures of image quality to optimization and evaluation of three-dimensional reconstruction-based compensation methods in myocardial perfusion SPECT.

Authors:  Eric C Frey; Karen L Gilland; Benjamin M W Tsui
Journal:  IEEE Trans Med Imaging       Date:  2002-09       Impact factor: 10.048

3.  Optimised tracer-dependent dosage cards to obtain weight-independent effective doses.

Authors:  F Jacobs; H Thierens; A Piepsz; K Bacher; C Van de Wiele; H Ham; R A Dierckx
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-12-24       Impact factor: 9.236

4.  The new EANM paediatric dosage card.

Authors:  M Lassmann; L Biassoni; M Monsieurs; C Franzius; F Jacobs
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-04-04       Impact factor: 9.236

5.  Maximum likelihood estimation of receiver operating characteristic (ROC) curves from continuously-distributed data.

Authors:  C E Metz; B A Herman; J H Shen
Journal:  Stat Med       Date:  1998-05-15       Impact factor: 2.373

6.  Pediatric radiopharmaceutical administered doses: 2010 North American consensus guidelines.

Authors:  Michael J Gelfand; Marguerite T Parisi; S Ted Treves
Journal:  J Nucl Med       Date:  2011-01-13       Impact factor: 10.057

7.  Biokinetic behavior of technetium-99m-DMSA in children.

Authors:  K Evans; M F Lythgoe; P J Anderson; T Smith; I Gordon
Journal:  J Nucl Med       Date:  1996-08       Impact factor: 10.057

8.  Radiation dosimetry of technetium-99m-DMSA in children.

Authors:  T Smith; K Evans; M F Lythgoe; P J Anderson; I Gordon
Journal:  J Nucl Med       Date:  1996-08       Impact factor: 10.057

9.  Dosimetry and adequacy of CT-based attenuation correction for pediatric PET: phantom study.

Authors:  Frederic H Fahey; Matthew R Palmer; Keith J Strauss; Robert E Zimmerman; Ramsey D Badawi; S Ted Treves
Journal:  Radiology       Date:  2007-02-09       Impact factor: 11.105

10.  An investigation of the trade-off between the count level and image quality in myocardial perfusion SPECT using simulated images: the effects of statistical noise and object variability on defect detectability.

Authors:  Xin He; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2010-08-06       Impact factor: 3.609

View more
  19 in total

1.  Image quality and lesion detectability in low-dose pediatric 18F-FDG scans using total-body PET/CT.

Authors:  Yu-Mo Zhao; Ying-He Li; Tao Chen; Wei-Guang Zhang; Lin-Hao Wang; Jiatai Feng; Chenwei Li; Xu Zhang; Wei Fan; Ying-Ying Hu
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-03-18       Impact factor: 9.236

2.  Paediatric radiopharmaceutical administration: harmonization of the 2007 EANM paediatric dosage card (version 1.5.2008) and the 2010 North American consensus guidelines.

Authors:  Michael Lassmann; S Ted Treves
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-03-06       Impact factor: 9.236

3.  Current pediatric administered activity guidelines for 99m Tc-DMSA SPECT based on patient weight do not provide the same task-based image quality.

Authors:  Ye Li; Shannon O'Reilly; Donika Plyku; S Ted Treves; Frederic Fahey; Yong Du; Xinhua Cao; Briana Sexton-Stallone; Justin Brown; George Sgouros; Wesley E Bolch; Eric C Frey
Journal:  Med Phys       Date:  2019-09-20       Impact factor: 4.071

4.  A comparison of resampling schemes for estimating model observer performance with small ensembles.

Authors:  Fatma E A Elshahaby; Abhinav K Jha; Michael Ghaly; Eric C Frey
Journal:  Phys Med Biol       Date:  2017-08-22       Impact factor: 3.609

5.  Re-evaluation of pediatric 18F-FDG dosimetry: Cristy-Eckerman versus UF/NCI hybrid computational phantoms.

Authors:  Kitiwat Khamwan; Shannon E O'Reilly; Donika Plyku; Alison Goodkind; Anders Josefsson; Xinhua Cao; Frederic H Fahey; S Ted Treves; Wesley E Bolch; George Sgouros
Journal:  Phys Med Biol       Date:  2018-08-14       Impact factor: 3.609

Review 6.  Dose Estimation in Pediatric Nuclear Medicine.

Authors:  Frederic H Fahey; Alison B Goodkind; Donika Plyku; Kitiwat Khamwan; Shannon E O'Reilly; Xinhua Cao; Eric C Frey; Ye Li; Wesley E Bolch; George Sgouros; S Ted Treves
Journal:  Semin Nucl Med       Date:  2016-11-09       Impact factor: 4.446

7.  Internal photon and electron dosimetry of the newborn patient--a hybrid computational phantom study.

Authors:  Michael Wayson; Choonsik Lee; George Sgouros; S Ted Treves; Eric Frey; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2012-03-07       Impact factor: 3.609

8.  New Theoretical Results on Channelized Hotelling Observer Performance Estimation with Known Difference of Class Means.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  IEEE Trans Nucl Sci       Date:  2013-01-11       Impact factor: 1.679

9.  A risk index for pediatric patients undergoing diagnostic imaging with (99m)Tc-dimercaptosuccinic acid that accounts for body habitus.

Authors:  Shannon E O'Reilly; Donika Plyku; George Sgouros; Frederic H Fahey; S Ted Treves; Eric C Frey; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2016-03-01       Impact factor: 3.609

10.  A projection image database to investigate factors affecting image quality in weight-based dosing: application to pediatric renal SPECT.

Authors:  Ye Li; Shannon O'Reilly; Donika Plyku; S Ted Treves; Yong Du; Frederic Fahey; Xinhua Cao; Abhinav K Jha; George Sgouros; Wesley E Bolch; Eric C Frey
Journal:  Phys Med Biol       Date:  2018-07-09       Impact factor: 3.609