Literature DB >> 27493982

Design of a practical model-observer-based image quality assessment method for x-ray computed tomography imaging systems.

Hsin-Wu Tseng1, Jiahua Fan2, Matthew A Kupinski3.   

Abstract

The use of a channelization mechanism on model observers not only makes mimicking human visual behavior possible, but also reduces the amount of image data needed to estimate the model observer parameters. The channelized Hotelling observer (CHO) and channelized scanning linear observer (CSLO) have recently been used to assess CT image quality for detection tasks and combined detection/estimation tasks, respectively. Although the use of channels substantially reduces the amount of data required to compute image quality, the number of scans required for CT imaging is still not practical for routine use. It is our desire to further reduce the number of scans required to make CHO or CSLO an image quality tool for routine and frequent system validations and evaluations. This work explores different data-reduction schemes and designs an approach that requires only a few CT scans. Three different kinds of approaches are included in this study: a conventional CHO/CSLO technique with a large sample size, a conventional CHO/CSLO technique with fewer samples, and an approach that we will show requires fewer samples to mimic conventional performance with a large sample size. The mean value and standard deviation of areas under ROC/EROC curve were estimated using the well-validated shuffle approach. The results indicate that an 80% data reduction can be achieved without loss of accuracy. This substantial data reduction is a step toward a practical tool for routine-task-based QA/QC CT system assessment.

Entities:  

Keywords:  CHO; CSLO; data reduction; leave-one-out likelihood; model observer

Year:  2016        PMID: 27493982      PMCID: PMC4963469          DOI: 10.1117/1.JMI.3.3.035503

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  11 in total

1.  Observer signal-to-noise ratios for the ML-EM algorithm.

Authors:  Craig K Abbey; Harrison H Barrett; Donald W Wilson
Journal:  Proc SPIE Int Soc Opt Eng       Date:  1996-01-01

2.  Intercomparison of methods for image quality characterization. II. Noise power spectrum.

Authors:  James T Dobbins; Ehsan Samei; Nicole T Ranger; Ying Chen
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

3.  Estimation receiver operating characteristic curve and ideal observers for combined detection/estimation tasks.

Authors:  Eric Clarkson
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-12       Impact factor: 2.129

4.  A channelized Hotelling observer study of lesion detection in SPECT MAP reconstruction using anatomical priors.

Authors:  S Kulkarni; P Khurd; I Hsiao; L Zhou; G Gindi
Journal:  Phys Med Biol       Date:  2007-05-23       Impact factor: 3.609

5.  Estimating random signal parameters from noisy images with nuisance parameters: linear and scanning-linear methods.

Authors:  Meredith Kathryn Whitaker; Eric Clarkson; Harrison H Barrett
Journal:  Opt Express       Date:  2008-05-26       Impact factor: 3.894

6.  Channelized Hotelling observers for the assessment of volumetric imaging data sets.

Authors:  Ljiljana Platiša; Bart Goossens; Ewout Vansteenkiste; Subok Park; Brandon D Gallas; Aldo Badano; Wilfried Philips
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2011-06-01       Impact factor: 2.129

7.  Assessing image quality and dose reduction of a new x-ray computed tomography iterative reconstruction algorithm using model observers.

Authors:  Hsin-Wu Tseng; Jiahua Fan; Matthew A Kupinski; Paavana Sainath; Jiang Hsieh
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

8.  Model observers for assessment of image quality.

Authors:  H H Barrett; J Yao; J P Rolland; K J Myers
Journal:  Proc Natl Acad Sci U S A       Date:  1993-11-01       Impact factor: 11.205

9.  Human- and model-observer performance in ramp-spectrum noise: effects of regularization and object variability.

Authors:  C K Abbey; H H Barrett
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2001-03       Impact factor: 2.129

10.  Channelized hotelling and human observer correlation for lesion detection in hepatic SPECT imaging.

Authors:  H C Gifford; M A King; D J de Vries; E J Soares
Journal:  J Nucl Med       Date:  2000-03       Impact factor: 10.057

View more
  2 in total

1.  A comparison of resampling schemes for estimating model observer performance with small ensembles.

Authors:  Fatma E A Elshahaby; Abhinav K Jha; Michael Ghaly; Eric C Frey
Journal:  Phys Med Biol       Date:  2017-08-22       Impact factor: 3.609

2.  Assessing computed tomography image quality for combined detection and estimation tasks.

Authors:  Hsin-Wu Tseng; Jiahua Fan; Matthew A Kupinski
Journal:  J Med Imaging (Bellingham)       Date:  2017-11-21