Literature DB >> 24051342

Evaluation of the channelized Hotelling observer with an internal-noise model in a train-test paradigm for cardiac SPECT defect detection.

Jovan G Brankov1.   

Abstract

The channelized Hotelling observer (CHO) has become a widely used approach for evaluating medical image quality, acting as a surrogate for human observers in early-stage research on assessment and optimization of imaging devices and algorithms. The CHO is typically used to measure lesion detectability. Its popularity stems from experiments showing that the CHO's detection performance can correlate well with that of human observers. In some cases, CHO performance overestimates human performance; to counteract this effect, an internal-noise model is introduced, which allows the CHO to be tuned to match human-observer performance. Typically, this tuning is achieved using example data obtained from human observers. We argue that this internal-noise tuning step is essentially a model training exercise; therefore, just as in supervised learning, it is essential to test the CHO with an internal-noise model on a set of data that is distinct from that used to tune (train) the model. Furthermore, we argue that, if the CHO is to provide useful insights about new imaging algorithms or devices, the test data should reflect such potential differences from the training data; it is not sufficient simply to use new noise realizations of the same imaging method. Motivated by these considerations, the novelty of this paper is the use of new model selection criteria to evaluate ten established internal-noise models, utilizing four different channel models, in a train-test approach. Though not the focus of the paper, a new internal-noise model is also proposed that outperformed the ten established models in the cases tested. The results, using cardiac perfusion SPECT data, show that the proposed train-test approach is necessary, as judged by the newly proposed model selection criteria, to avoid spurious conclusions. The results also demonstrate that, in some models, the optimal internal-noise parameter is very sensitive to the choice of training data; therefore, these models are prone to overfitting, and will not likely generalize well to new data. In addition, we present an alternative interpretation of the CHO as a penalized linear regression wherein the penalization term is defined by the internal-noise model.

Entities:  

Mesh:

Year:  2013        PMID: 24051342      PMCID: PMC4136380          DOI: 10.1088/0031-9155/58/20/7159

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  32 in total

1.  Characterizing human perceptual inefficiencies with equivalent internal noise.

Authors:  Z L Lu; B A Dosher
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  1999-03       Impact factor: 2.129

2.  Prediction of human observer performance by numerical observers: an experimental study.

Authors:  T K Narayan; G T Herman
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  1999-03       Impact factor: 2.129

3.  Optimal shifted estimates of human-observer templates in two-alternative forced-choice experiments.

Authors:  Craig K Abbey; Miguel P Eckstein
Journal:  IEEE Trans Med Imaging       Date:  2002-05       Impact factor: 10.048

4.  Evaluation of internal noise methods for Hotelling observer models.

Authors:  Yani Zhang; Binh T Pham; Miguel P Eckstein
Journal:  Med Phys       Date:  2007-08       Impact factor: 4.071

5.  A channelized Hotelling observer study of lesion detection in SPECT MAP reconstruction using anatomical priors.

Authors:  S Kulkarni; P Khurd; I Hsiao; L Zhou; G Gindi
Journal:  Phys Med Biol       Date:  2007-05-23       Impact factor: 3.609

6.  Automated computer evaluation and optimization of image compression of x-ray coronary angiograms for signal known exactly detection tasks.

Authors:  Miguel Eckstein; Jay Bartroff; Craig Abbey; James Whiting; Francois Bochud
Journal:  Opt Express       Date:  2003-03-10       Impact factor: 3.894

7.  Statistical comparison of two ROC-curve estimates obtained from partially-paired datasets.

Authors:  C E Metz; B A Herman; C A Roe
Journal:  Med Decis Making       Date:  1998 Jan-Mar       Impact factor: 2.583

8.  Visual signal detection. IV. Observer inconsistency.

Authors:  A E Burgess; B Colborne
Journal:  J Opt Soc Am A       Date:  1988-04       Impact factor: 2.129

9.  The effect of nonlinear human visual system components on performance of a channelized Hotelling observer in structured backgrounds.

Authors:  Yani Zhang; Binh T Pham; Miguel P Eckstein
Journal:  IEEE Trans Med Imaging       Date:  2006-10       Impact factor: 10.048

10.  Human linear template with mammographic backgrounds estimated with a genetic algorithm.

Authors:  Cyril Castella; Craig K Abbey; Miguel P Eckstein; Francis R Verdun; Karen Kinkel; François O Bochud
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-12       Impact factor: 2.129

View more
  12 in total

1.  Anthropomorphic model observer performance in three-dimensional detection task for low-contrast computed tomography.

Authors:  Alexandre Ba; Miguel P Eckstein; Damien Racine; Julien G Ott; Francis Verdun; Sabine Kobbe-Schmidt; François O Bochud
Journal:  J Med Imaging (Bellingham)       Date:  2015-12-29

2.  Factors affecting the normality of channel outputs of channelized model observers: an investigation using realistic myocardial perfusion SPECT images.

Authors:  Fatma E A Elshahaby; Michael Ghaly; Abhinav K Jha; Eric C Frey
Journal:  J Med Imaging (Bellingham)       Date:  2016-01-28

3.  Channelized Hotelling observer correlation with human observers for low-contrast detection in liver CT images.

Authors:  Alexandre Ba; Craig K Abbey; Damien Racine; Anaïs Viry; Francis R Verdun; Sabine Schmidt; François O Bochud
Journal:  J Med Imaging (Bellingham)       Date:  2019-05-20

4.  Evaluation of lesion detectability in positron emission tomography when using a convergent penalized likelihood image reconstruction method.

Authors:  Kristen A Wangerin; Sangtae Ahn; Scott Wollenweber; Steven G Ross; Paul E Kinahan; Ravindra M Manjeshwar
Journal:  J Med Imaging (Bellingham)       Date:  2016-11-22

5.  Generalization Evaluation of Machine Learning Numerical Observers for Image Quality Assessment.

Authors:  Mahdi M Kalayeh; Thibault Marin; Jovan G Brankov
Journal:  IEEE Trans Nucl Sci       Date:  2013-06       Impact factor: 1.679

6.  A comparison of resampling schemes for estimating model observer performance with small ensembles.

Authors:  Fatma E A Elshahaby; Abhinav K Jha; Michael Ghaly; Eric C Frey
Journal:  Phys Med Biol       Date:  2017-08-22       Impact factor: 3.609

7.  Theoretical Analysis of Penalized Maximum-Likelihood Patlak Parametric Image Reconstruction in Dynamic PET for Lesion Detection.

Authors:  Li Yang; Guobao Wang; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2015-11-23       Impact factor: 10.048

8.  Model and human observer reproducibility for detection of microcalcification clusters in digital breast tomosynthesis images of three-dimensionally structured test object.

Authors:  Dimitar Petrov; Nicholas Marshall; Kenneth Young; Guozhi Zhang; Hilde Bosmans
Journal:  J Med Imaging (Bellingham)       Date:  2019-03-23

9.  DeepAMO: a multi-slice, multi-view anthropomorphic model observer for visual detection tasks performed on volume images.

Authors:  Ye Li; Junyu Chen; Justin L Brown; S Ted Treves; Xinhua Cao; Frederic H Fahey; George Sgouros; Wesley E Bolch; Eric C Frey
Journal:  J Med Imaging (Bellingham)       Date:  2021-01-28

10.  Task-based quantification of image quality using a model observer in abdominal CT: a multicentre study.

Authors:  Damien Racine; Nick Ryckx; Alexandre Ba; Fabio Becce; Anais Viry; Francis R Verdun; Sabine Schmidt
Journal:  Eur Radiol       Date:  2018-06-01       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.