Is the PTW 60019 microDiamond a suitable candidate for small field reference dosimetry?

Vanessa De Coste1, Paolo Francescon, Marco Marinelli, Laura Masi, Lucia Paganini, Maria Pimpinella, Giuseppe Prestopino, Serenella Russo, Antonella Stravato, Claudio Verona, Gianluca Verona-Rinati.   

Abstract

A systematic study of the PTW microDiamond (MD) output factors (OF) is reported, aimed at clarifying its response in small fields and investigating its suitability for small field reference dosimetry. Ten MDs were calibrated under 60Co irradiation. OF measurements were performed in 6 MV photon beams by a CyberKnife M6, a Varian DHX and an Elekta Synergy linacs. Two PTW silicon diodes E (Si-D) were used for comparison. The results obtained by the MDs were evaluated in terms of absorbed dose to water determination in reference conditions and OF measurements, and compared to the results reported in the recent literature. To this purpose, the Monte Carlo (MC) beam-quality correction factor, [Formula: see text], was calculated for the MD, and the small field output correction factors, [Formula: see text], were calculated for both the MD and the Si-D by two different research groups. An empirical function was also derived, providing output correction factors within 0.5% from the MC values calculated for all of the three linacs. A high reproducibility of the dosimetric properties was observed among the ten MDs. The experimental [Formula: see text] values are in agreement within 1% with the MC calculated ones. Output correction factors within  +0.7% and  -1.4% were obtained down to field sizes as narrow as 5 mm. The resulting MD and Si-D field factors are in agreement within 0.2% in the case of CyberKnife measurements and 1.6% in the other cases. This latter higher spread of the data was demonstrated to be due to a lower reproducibility of small beam sizes defined by jaws or multi leaf collimators. The results of the present study demonstrate the reproducibility of the MD response and provide a validation of the MC modelling of this device. In principle, accurate reference dosimetry is thus feasible by using the microDiamond dosimeter for field sizes down to 5 mm.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28791962     DOI: 10.1088/1361-6560/aa7e59

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

1.  Characterization of a microSilicon diode detector for small-field photon beam dosimetry.

Authors:  Yuichi Akino; Masateru Fujiwara; Keita Okamura; Hiroya Shiomi; Hirokazu Mizuno; Fumiaki Isohashi; Osamu Suzuki; Yuji Seo; Keisuke Tamari; Kazuhiko Ogawa
Journal:  J Radiat Res       Date:  2020-05-22       Impact factor: 2.724

2.  A novel method for the determination of field output factors and output correction factors for small static fields for six diodes and a microdiamond detector in megavoltage photon beams.

Authors:  Božidar Casar; Eduard Gershkevitsh; Ignasi Mendez; Slaven Jurković; M Saiful Huq
Journal:  Med Phys       Date:  2018-12-24       Impact factor: 4.071

3.  The role of radiation-induced charge imbalance on the dose-response of a commercial synthetic diamond detector in small field dosimetry.

Authors:  Hui Khee Looe; Daniela Poppinga; Rafael Kranzer; Isabel Büsing; Tuba Tekin; Ann-Britt Ulrichs; Björn Delfs; Dennis Vogt; Jan Würfel; Björn Poppe
Journal:  Med Phys       Date:  2019-05-02       Impact factor: 4.071

4.  Validation of the preconfigured Varian Ethos Acuros XB Beam Model for treatment planning dose calculations: A dosimetric study.

Authors:  Yunfei Hu; Mikel Byrne; Ben Archibald-Heeren; Nick Collett; Guilin Liu; Trent Aland
Journal:  J Appl Clin Med Phys       Date:  2020-10-17       Impact factor: 2.102

5.  Characterisation of a synthetic diamond detector for end-to-end dosimetry in stereotactic body radiotherapy and radiosurgery.

Authors:  Maddison Shaw; Jessica Lye; Andrew Alves; Stephanie Keehan; Joerg Lehmann; Maximilian Hanlon; John Kenny; John Baines; Claudiu Porumb; Moshi Geso; Rhonda Brown
Journal:  Phys Imaging Radiat Oncol       Date:  2021-10-19

6.  Development of a high-resolution two-dimensional detector-based dose verification system for tumor-tracking irradiation in the CyberKnife system.

Authors:  Fumitaka Kawabata; Takeshi Kamomae; Kuniyasu Okudaira; Masataka Komori; Hiroshi Oguchi; Motoharu Sasaki; Masaki Mori; Mariko Kawamura; Shinji Abe; Shunichi Ishihara; Shinji Naganawa
Journal:  J Appl Clin Med Phys       Date:  2022-07-05       Impact factor: 2.243

7.  High spatial resolution inorganic scintillator detector for high-energy X-ray beam at small field irradiation.

Authors:  Sree Bash Chandra Debnath; Carole Fauquet; Agnes Tallet; Anthony Goncalves; Sébastien Lavandier; Franck Jandard; Didier Tonneau; Julien Darreon
Journal:  Med Phys       Date:  2020-01-23       Impact factor: 4.071

8.  Small field output correction factors of the microSilicon detector and a deeper understanding of their origin by quantifying perturbation factors.

Authors:  Carolin Weber; Rafael Kranzer; Jan Weidner; Kevin Kröninger; Björn Poppe; Hui Khee Looe; Daniela Poppinga
Journal:  Med Phys       Date:  2020-04-13       Impact factor: 4.071

9.  Design, realization, and characterization of a novel diamond detector prototype for FLASH radiotherapy dosimetry.

Authors:  Marco Marinelli; Giuseppe Felici; Federica Galante; Alessia Gasparini; Lucia Giuliano; Sophie Heinrich; Matteo Pacitti; Giuseppe Prestopino; Verdi Vanreusel; Dirk Verellen; Claudio Verona; Gianluca Verona Rinati
Journal:  Med Phys       Date:  2022-01-31       Impact factor: 4.506

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.