Literature DB >> 28785906

Comparison of 3D plate and locking plate in treatment of mandibular fracture-a clinical study.

Sakshi Aggarwal1, Manpreet Singh2, Palash Modi3, Esha Walia4, Rachit Aggarwal5.   

Abstract

INTRODUCTION: This study was performed to evaluate the efficacy and post-operative complication of 3-dimensional (3D) titanium miniplate and locking plate in mandibular fractures (parasymphysis, symphysis, body, and angle).
MATERIALS AND METHODS: Forty patients, with non-comminuted mandibular fractures treated with open reduction and internal fixation using 3D titanium miniplate system or locking plate system through an intra-oral approach, were included in this study. All patients were systematically monitored up to 2 months post-operatively. Parameters recorded were infection, occlusal discrepancies, hardware failure, wound dehiscence, sensory disturbance of the inferior alveolar nerve, and stability of fractured segments.
RESULTS: Forty patients with mandibular fracture were divided into two groups randomly without any bias. The fractures of all 40 patients were found to be adequately fixed when checked intra-operatively after fixation. One patient (2.5%) of the 3D plate group developed an infection on the first and second post-operative visit and was treated by antibiotic coverage. One patient in the locking plate group (2.5%) reported wound dehiscence after the first week follow-up.
CONCLUSION: Both 3D titanium miniplates and locking plate are effective in the treatment of mandibular fractures, and overall complication rates are lesser. However, the 3D plating system uses less hardware in cases of parasymphysis and symphysis fractures and more hardware in cases of body and angle fractures.

Entities:  

Keywords:  3-D plate; Locking plate; Mandibular fracture

Mesh:

Substances:

Year:  2017        PMID: 28785906     DOI: 10.1007/s10006-017-0642-1

Source DB:  PubMed          Journal:  Oral Maxillofac Surg        ISSN: 1865-1550


  13 in total

1.  Comparative evaluation of 2.0-mm locking plate system vs 2.0-mm nonlocking plate system for mandibular fracture: a prospective randomized study.

Authors:  V Singh; I Kumar; A Bhagol
Journal:  Int J Oral Maxillofac Surg       Date:  2010-12-30       Impact factor: 2.789

2.  Complication rates associated with different treatments for mandibular fractures.

Authors:  J C Moreno; A Fernández; J A Ortiz; J J Montalvo
Journal:  J Oral Maxillofac Surg       Date:  2000-03       Impact factor: 1.895

3.  Mandibular fracture osteosynthesis: a comparison of three techniques.

Authors:  T F Renton; D Wiesenfeld
Journal:  Br J Oral Maxillofac Surg       Date:  1996-04       Impact factor: 1.651

4.  Clinical aspects of a 2.0-mm locking plate system for mandibular fracture surgery.

Authors:  Sebastian Sauerbier; Jana Kuenz; Silke Hauptmann; Christiaan Frederik Hoogendijk; Niels Liebehenschel; Ralf Schön; Rainer Schmelzeisen; Ralf Gutwald
Journal:  J Craniomaxillofac Surg       Date:  2010-02-13       Impact factor: 2.078

5.  Comparison of 3-dimensional and standard miniplate fixation in the management of mandibular fractures.

Authors:  Manoj Kumar Jain; K S Manjunath; B K Bhagwan; Dipit K Shah
Journal:  J Oral Maxillofac Surg       Date:  2010-04-22       Impact factor: 1.895

6.  Fixation of mandibular angle fractures with a 2.0-mm 3-dimensional curved angle strut plate.

Authors:  Claude Guimond; James V Johnson; Jose M Marchena
Journal:  J Oral Maxillofac Surg       Date:  2005-02       Impact factor: 1.895

7.  Use of straight and curved 3-dimensional titanium miniplates for fracture fixation at the mandibular angle.

Authors:  Juergen Zix; Olivier Lieger; Tateyuki Iizuka
Journal:  J Oral Maxillofac Surg       Date:  2007-09       Impact factor: 1.895

8.  New innovations in craniomaxillofacial fixation: the 2.0 lock system.

Authors:  Brian Alpert; Rolf Gutwald; Rainer Schmelzeisen
Journal:  Keio J Med       Date:  2003-06

9.  Mandibular osteosynthesis by miniature screwed plates via a buccal approach.

Authors:  M Champy; J P Loddé; R Schmitt; J H Jaeger; D Muster
Journal:  J Maxillofac Surg       Date:  1978-02

10.  Infection rate in mandibular angle fractures treated with a 2.0-mm 8-hole curved strut plate.

Authors:  Peter Bui; Nagi Demian; Patrick Beetar
Journal:  J Oral Maxillofac Surg       Date:  2009-04       Impact factor: 1.895

View more
  3 in total

1.  Comparative study of outcomes between locking plates and three-dimensional plates in mandibular fractures.

Authors:  Shaikh Amjad; M D Kalim Ansari; Syed S Ahmad; Tabishur Rahman
Journal:  Natl J Maxillofac Surg       Date:  2020-12-16

2.  Effect of Joint Use of External Minifixator and Titanium Lockplate on Total Active Motion Range and Hand Function Recovery in Comminuted Metacarpal and Phalanx Fracture Patients.

Authors:  Yao Li; Hongwei Zhang
Journal:  J Healthc Eng       Date:  2022-01-25       Impact factor: 2.682

3.  Treatment of Mandible Fractures Using a Miniplate System: A Retrospective Analysis.

Authors:  Lauren Bohner; Fabian Beiglboeck; Stephanie Schwipper; Rômulo Maciel Lustosa; Carla Pieirna Marino Segura; Johannes Kleinheinz; Susanne Jung
Journal:  J Clin Med       Date:  2020-09-10       Impact factor: 4.241

  3 in total