Literature DB >> 20417012

Comparison of 3-dimensional and standard miniplate fixation in the management of mandibular fractures.

Manoj Kumar Jain1, K S Manjunath, B K Bhagwan, Dipit K Shah.   

Abstract

PURPOSE: The aim of this follow-up study was to compare 3-dimensional (3D) and standard (Champy's) miniplate fixation in the management of mandibular fractures, and to analyze advantages and disadvantages of one over the other. PATIENTS AND METHODS: A prospective randomized clinical trial was carried out in patients with well-defined inclusion and exclusion criteria. Patients were followed for 2 months for wound dehiscence, infection, segmental mobility, postoperative occlusion, significant period of postoperative complications, and radiological evaluation of reduction and fixation.
RESULTS: Twenty patients were enrolled in both the groups with no case of wound dehiscence. In group 1, 2 patients had mild segmental mobility (P = .07), 2 patients had surgical site infection (P = .07), and 2 patients involving mental nerve had involved roots of teeth (P = .07). Radiological evaluation did not show any statistically significant difference in reduction (P = 1.4), but showed a significant difference (P = .03) in fixation between the 2 groups, especially in cases involving the mental nerve (ie, fracture near or involving the mental foramen) and oblique fractures.
CONCLUSION: Champy's miniplate system is a better and easier method than the 3D miniplate system for fixation of mandibular fractures. In comparison, the 3D miniplate system is unfavorable for use in cases of oblique fractures and those involving the mental nerve, and is also difficult to adapt. In most cases, it provides good stability but with excessive implant material because of extra vertical bars incorporated for countering the torque forces. However, operative time is less because of simultaneous stabilization at both superior and inferior borders. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20417012     DOI: 10.1016/j.joms.2009.07.083

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  21 in total

1.  Efficacy of 3-Dimensional plates over Champys miniplates in mandibular anterior fractures.

Authors:  Dhananjay H Barde; Anupama Mudhol; Fareedi Mukram Ali; R S Madan; Sanjay Kar; Farheen Ustaad
Journal:  J Int Oral Health       Date:  2014-02-26

2.  A Comparative Study of 3-Dimensional Titanium Versus 2-Dimensional Titanium Miniplates for Open Reduction and Fixation of Mandibular Parasymphysis Fracture.

Authors:  Yogesh Mittal; K George Varghese; S Mohan; N Jayakumar; Somil Chhag
Journal:  J Maxillofac Oral Surg       Date:  2015-03-27

3.  Treatment of Mandibular Angle Fractures with Single Three-Dimensional Locking Miniplates without Maxillomandibular Fixation: How Much Fixation Is Required?

Authors:  Sanjay Rastogi; Sam Paul; Sumedha Kukreja; Karun Aggarwal; Rupshikha Choudhury; Amit Bhugra; Niranjana Prasad Indra B; Moazzam Jawaid
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2017-03-29

4.  Comparison of 3D plate and locking plate in treatment of mandibular fracture-a clinical study.

Authors:  Sakshi Aggarwal; Manpreet Singh; Palash Modi; Esha Walia; Rachit Aggarwal
Journal:  Oral Maxillofac Surg       Date:  2017-08-07

5.  Use of 3-d plate in displaced angle fracture of mandible.

Authors:  Uma Shanker Pal; R K Singh; Satish Dhasmana; Somdipto Das; Sanjib K Das
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2013-01-15

6.  Management of mandibular angle fractures using a 1.7 mm 3-dimensional strut plate.

Authors:  Varnika Pandey; Ongkila Bhutia; Shakil Ahmed Nagori; Ashu Seith; Ajoy Roychoudhury
Journal:  J Oral Biol Craniofac Res       Date:  2015-11-27

7.  Standard 3D Titanium Miniplate Versus Locking 3D Miniplate in Fracture of Mandible: A Prospective Comparative Study.

Authors:  Arjun Singh; K V Arunkumar
Journal:  J Maxillofac Oral Surg       Date:  2015-07-29

8.  A Prospective Randomized Clinical Trial Comparing 3D and Standard Miniplates in Treatment of Mandibular Symphysis and Parasymphysis Fractures.

Authors:  Mohit Agarwal; Balram Meena; D K Gupta; Anjali Dave Tiwari; Sunil Kumar Jakhar
Journal:  J Maxillofac Oral Surg       Date:  2013-02-15

9.  Bite Force as a Parameter for Comparison Between Three-Dimensional and Standard Titanium Miniplates for the Management of Anterior Mandibular Fractures: A Prospective Randomized Double-Blinded Clinical Trial.

Authors:  Manoj Kumar Jain; Priyadarshini Kerur
Journal:  J Maxillofac Oral Surg       Date:  2018-02-09

10.  3-D Miniplates Versus Conventional Miniplates in Treatment of Mandible Fractures.

Authors:  Niranjan Mishra; Nirav Thakkar; Indubhusan Kar; Shadab Ali Baig; Gaurav Sharma; Rosalin Kar; Gyana Ranjan Sahu; Krishna Gopal Birmiwal
Journal:  J Maxillofac Oral Surg       Date:  2017-12-14