Abstract

PURPOSE: The use of a 2.0-mm locking plate system was evaluated in mandibular surgery. PATIENTS AND METHODS: 53 patients (42 male, 11 female) with a total of 56 mandibular fractures were treated with a 2.0-mm mini-locking-plate system and retrospectively examined. Gender, age, cause of fracture, surgical access, classification of fractures, osteosynthesis, postsurgical findings and complications were evaluated.
RESULTS: Assault in male patients (mean age 31) was the most common aetiological factor. Fractures in women (mean age 43 years) mostly occurred due to falls. Mandibular angle fractures were the most common and this anatomical site also presented the highest complication rate. Only 6% of patients had minor occlusal disturbance postoperatively, and minor complications (infections and dehiscence) occurred in 14% of patients in this study. Major complications only occurred in one patient included in the study (1.9%). Risk factors for the development of complications in this series were a history of alcohol or tobacco use, mandibular angle fractures, associated facial fractures, presurgical occlusal disturbance and concomitant dental infections. Surgical access to the fracture and the interval from injury to surgery was not associated with the development of complications.
CONCLUSIONS: The use of a 2.0-mm locking plate system with its advantages of improved handling characteristics, increased stability, shorter surgical time and the preservation of bony perfusion is a viable alternative to conventional miniplates in the management of mandibular fractures.
Copyright © 2010 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20156692     DOI: 10.1016/j.jcms.2010.01.001

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  4 in total

1.  Comparison of 3D plate and locking plate in treatment of mandibular fracture-a clinical study.

Authors:  Sakshi Aggarwal; Manpreet Singh; Palash Modi; Esha Walia; Rachit Aggarwal
Journal:  Oral Maxillofac Surg       Date:  2017-08-07

2.  Comparison of a 2.0-mm locking system with conventional 2.0- and 2.4-mm systems in the treatment of mandibular fractures: a randomized controlled trial.

Authors:  Rubens Camino Junior; Rogério Bonfante Moraes; Constantin Landes; João Gualberto C Luz
Journal:  Oral Maxillofac Surg       Date:  2017-06-12

3.  Cortical lag screw fixation for the management of mandibular injuries.

Authors:  Shadia Abdel-Hameed Elsayed
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2020-12-31

4.  Retrospective study of mandibular angle fractures treated with three different fixation systems.

Authors:  Krushna Bhatt; Satyavrat Arya; Ongkila Bhutia; Sandeep Pandey; Ajoy Roychoudhury
Journal:  Natl J Maxillofac Surg       Date:  2015 Jan-Jun
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.