Literature DB >> 15690289

Fixation of mandibular angle fractures with a 2.0-mm 3-dimensional curved angle strut plate.

Claude Guimond1, James V Johnson, Jose M Marchena.   

Abstract

PURPOSE: The aim of this study was to evaluate our experience and complication rate with the use of a 3-dimensional 2.0-mm curved angle strut plate for mandibular angle fracture fixation. PATIENTS AND METHODS: This was a retrospective evaluation of 37 patients with noncomminuted mandibular angle fractures fixated with a transorally placed curved 2.0-mm strut plate. Postoperative intermaxillary fixation was used in 5 patients for a mean period of 22 days. A nonchewing diet was prescribed for 6 weeks. Records were reviewed for demographic information, medical history, fracture characteristics, operative management, and complications.
RESULTS: Two patients developed infections requiring plate removal and reapplication of fixation. Both of these patients had a molar in the fracture line that was left in place during the first operation. One patient developed a mucosal wound dehiscence without consequence. After a mean follow-up period of 10 weeks, 39.4% of patients with a postinjury/pretreatment inferior alveolar nerve deficit reported a return to normal sensation. All patients who developed a sensory deficit as a result of surgery reported full recovery of sensation. A persistent sensory deficit appeared to be related to fracture displacement.
CONCLUSION: Fixation of noncomminuted mandibular angle fractures with a 2.0-mm curved angle strut plate was predictable. This plate is low in profile, strong yet malleable, facilitating reduction and stabilization at both the superior and inferior borders. Development of a postoperative infection appeared to be related to failure of removal of a molar in the fracture line. The infection rate of 5.4% found in this study compares favorably with that seen with reconstruction plates. Use of this plate did not appear to cause a permanent sensory deficit in this study.

Entities:  

Mesh:

Year:  2005        PMID: 15690289     DOI: 10.1016/j.joms.2004.03.018

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  38 in total

1.  Mandibular Osteosynthesis: A Comparative Evaluation of Two Different Fixation Systems Using 2.0 mm Titanium Miniplates and 3-D Locking Plates.

Authors:  Manoj Goyal; Karan Marya; Sonia Chawla; Richa Pandey
Journal:  J Maxillofac Oral Surg       Date:  2011-03-25

2.  Efficacy of 3-Dimensional plates over Champys miniplates in mandibular anterior fractures.

Authors:  Dhananjay H Barde; Anupama Mudhol; Fareedi Mukram Ali; R S Madan; Sanjay Kar; Farheen Ustaad
Journal:  J Int Oral Health       Date:  2014-02-26

3.  Treatment of mandibular angle fracture with a 2mm, 3 dimensional rectangular grid compression miniplates: A prospective clinical study.

Authors:  Samir Mansuri; Abdul Mujeeb Abdulkhayum; Giath Gazal; Mohammed Abid Zahir Hussain
Journal:  J Int Oral Health       Date:  2013-12-26

4.  Biomechanical comparison of four mandibular angle fracture fixation techniques.

Authors:  Jose Luis Muñante-Cardenas; Luis Augusto Passeri
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2014-11-20

5.  Mandibular Osteosynthesis: A Comparative Evaluation of Two Different Fixation Systems Using 2.0 mm Titanium Miniplates & 3-D Locking Plates.

Authors:  Manoj Goyal; Karan Marya; Sonia Chawla; Richa Pandey
Journal:  J Maxillofac Oral Surg       Date:  2011-05-22

6.  A Comparative Study of 3-Dimensional Titanium Versus 2-Dimensional Titanium Miniplates for Open Reduction and Fixation of Mandibular Parasymphysis Fracture.

Authors:  Yogesh Mittal; K George Varghese; S Mohan; N Jayakumar; Somil Chhag
Journal:  J Maxillofac Oral Surg       Date:  2015-03-27

7.  Evaluation of in vitro resistance of different 2.0-mm titanium plates on the mandibular angle sectioning.

Authors:  Marco Aurélio Kenichi Yamaji; Patrício José de Oliveira Neto; Michel de Campos Ribeiro; Lucas Cavalieri Pereira; Márcio de Morais; Cássio Edvard Sverzut; Alexandre Elias Trivellato
Journal:  Oral Maxillofac Surg       Date:  2015-03

8.  Use of 3-d plate in displaced angle fracture of mandible.

Authors:  Uma Shanker Pal; R K Singh; Satish Dhasmana; Somdipto Das; Sanjib K Das
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2013-01-15

9.  A Prospective Study of Strut versus Miniplate for Fractures of Mandibular Angle.

Authors:  Amy S Xue; John C Koshy; Erik M Wolfswinkel; William M Weathers; Kristina P Marsack; Larry H Hollier
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2013-06-24

10.  Complications of the use of trans-osseous wire osteosynthesis in the managementof compound, unfavorable and non-comminuted mandibular angle fractures.

Authors:  Charles E Anyanechi; Otasowie D Osunde; Birch D Saheeb
Journal:  Ghana Med J       Date:  2016-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.