Literature DB >> 19304038

Infection rate in mandibular angle fractures treated with a 2.0-mm 8-hole curved strut plate.

Peter Bui1, Nagi Demian, Patrick Beetar.   

Abstract

PURPOSE: The aim of this study was to determine the rate of postoperative infection and the efficacy of removing teeth in the line of mandibular angle fractures treated with 2.0-mm 8-hole titanium curved strut plates. Our understanding is that this method of repair is currently being used only in a few centers in the United States.
MATERIALS AND METHODS: A retrospective review of mandibular angle fractures treated with a 2.0-mm 8-hole strut plate during a 4-year period. Postoperative antibiotics were given for 1 week. Follow-up appointments were 4 weeks or longer. A nonchewing diet was instructed for 6 weeks. Data for all selected patients include the information such as age, gender, etiology of injuries, medical history, concurrent injuries, nerve deficits, pre- and postoperative antibiotic administration, postop infection, a presence or absence of teeth in the line of fractures, and whether these teeth were removed.
RESULTS: Four patients (4 of 49 or 8.2%) developed infections. Two of those patients had a tooth in the line of a fracture that was retained (2 of 14 or 14%). The third had a tooth in the line of a fracture that was extracted (1 of 18 or 5.6%). The fourth patient was 1 of the 17 patients who did not have teeth in the line of fracture and developed infection (1 of 17 or 5.9%). None of the patients developed failed hardware, malunion, nonunion, malocclusion, or iatrogenic nerve injury.
CONCLUSIONS: The use of a 2.0-mm 8-hole strut plate is associated with a low infection rate (8.2%). The infection rate for those mandibular angle fractures with teeth in the line of fracture retained was 14% compared with 5.6% for those fractures with the teeth in the line of fracture extracted.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19304038     DOI: 10.1016/j.joms.2008.08.034

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  19 in total

1.  Mandibular Osteosynthesis: A Comparative Evaluation of Two Different Fixation Systems Using 2.0 mm Titanium Miniplates and 3-D Locking Plates.

Authors:  Manoj Goyal; Karan Marya; Sonia Chawla; Richa Pandey
Journal:  J Maxillofac Oral Surg       Date:  2011-03-25

2.  Treatment of mandibular angle fracture with a 2mm, 3 dimensional rectangular grid compression miniplates: A prospective clinical study.

Authors:  Samir Mansuri; Abdul Mujeeb Abdulkhayum; Giath Gazal; Mohammed Abid Zahir Hussain
Journal:  J Int Oral Health       Date:  2013-12-26

3.  Mandibular Osteosynthesis: A Comparative Evaluation of Two Different Fixation Systems Using 2.0 mm Titanium Miniplates & 3-D Locking Plates.

Authors:  Manoj Goyal; Karan Marya; Sonia Chawla; Richa Pandey
Journal:  J Maxillofac Oral Surg       Date:  2011-05-22

4.  A Comparative Study of 3-Dimensional Titanium Versus 2-Dimensional Titanium Miniplates for Open Reduction and Fixation of Mandibular Parasymphysis Fracture.

Authors:  Yogesh Mittal; K George Varghese; S Mohan; N Jayakumar; Somil Chhag
Journal:  J Maxillofac Oral Surg       Date:  2015-03-27

5.  Treatment of Mandibular Angle Fractures with Single Three-Dimensional Locking Miniplates without Maxillomandibular Fixation: How Much Fixation Is Required?

Authors:  Sanjay Rastogi; Sam Paul; Sumedha Kukreja; Karun Aggarwal; Rupshikha Choudhury; Amit Bhugra; Niranjana Prasad Indra B; Moazzam Jawaid
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2017-03-29

6.  Comparison of 3D plate and locking plate in treatment of mandibular fracture-a clinical study.

Authors:  Sakshi Aggarwal; Manpreet Singh; Palash Modi; Esha Walia; Rachit Aggarwal
Journal:  Oral Maxillofac Surg       Date:  2017-08-07

7.  A Prospective Study of Strut versus Miniplate for Fractures of Mandibular Angle.

Authors:  Amy S Xue; John C Koshy; Erik M Wolfswinkel; William M Weathers; Kristina P Marsack; Larry H Hollier
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2013-06-24

8.  Evaluation of 2.0-mm Titanium Three-Dimensional Curved Angle Strut Plate in the Fixation of Mandibular Angle Fractures-A Prospective Clinical and Radiological Analysis.

Authors:  Gaurav Chhabaria; Rajshekhar Halli; Sanjay Chandan; Samir Joshi; Sneha Setiya; Anand Shah
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2014-02-20

9.  Management of mandibular angle fractures using a 1.7 mm 3-dimensional strut plate.

Authors:  Varnika Pandey; Ongkila Bhutia; Shakil Ahmed Nagori; Ashu Seith; Ajoy Roychoudhury
Journal:  J Oral Biol Craniofac Res       Date:  2015-11-27

10.  The influence of third molars in the line of mandibular angle fractures on wound and bone healing.

Authors:  N Ulbrich; T Ettl; W Waiss; M Gosau; A Moralis; T E Reichert; S Mueller
Journal:  Clin Oral Investig       Date:  2015-09-28       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.