Literature DB >> 28785850

Highly accelerated intracranial 4D flow MRI: evaluation of healthy volunteers and patients with intracranial aneurysms.

Jing Liu1, Louise Koskas2, Farshid Faraji2, Evan Kao2, Yan Wang2, Henrik Haraldsson2, Sarah Kefayati2, Chengcheng Zhu2, Sinyeob Ahn3, Gerhard Laub3, David Saloner2,4.   

Abstract

OBJECTIVES: To evaluate an accelerated 4D flow MRI method that provides high temporal resolution in a clinically feasible acquisition time for intracranial velocity imaging.
MATERIALS AND METHODS: Accelerated 4D flow MRI was developed by using a pseudo-random variable-density Cartesian undersampling strategy (CIRCUS) with the combination of k-t, parallel imaging and compressed sensing image reconstruction techniques (k-t SPARSE-SENSE). Four-dimensional flow data were acquired on five healthy volunteers and eight patients with intracranial aneurysms using CIRCUS (acceleration factor of R = 4, termed CIRCUS4) and GRAPPA (R = 2, termed GRAPPA2) as the reference method. Images with three times higher temporal resolution (R = 12, CIRCUS12) were also reconstructed from the same acquisition as CIRCUS4. Qualitative and quantitative image assessment was performed on the images acquired with different methods, and complex flow patterns in the aneurysms were identified and compared.
RESULTS: Four-dimensional flow MRI with CIRCUS was achieved in 5 min and allowed further improved temporal resolution of <30 ms. Volunteer studies showed similar qualitative and quantitative evaluation obtained with the proposed approach compared to the reference (overall image scores: GRAPPA2 3.2 ± 0.6; CIRCUS4 3.1 ± 0.7; CIRCUS12 3.3 ± 0.4; difference of the peak velocities: -3.83 ± 7.72 cm/s between CIRCUS4 and GRAPPA2, -1.72 ± 8.41 cm/s between CIRCUS12 and GRAPPA2). In patients with intracranial aneurysms, the higher temporal resolution improved capturing of the flow features in intracranial aneurysms (pathline visualization scores: GRAPPA2 2.2 ± 0.2; CIRCUS4 2.5 ± 0.5; CIRCUS12 2.7 ± 0.6).
CONCLUSION: The proposed rapid 4D flow MRI with a high temporal resolution is a promising tool for evaluating intracranial aneurysms in a clinically feasible acquisition time.

Entities:  

Keywords:  4D flow; Acceleration; Aneurysm; Compressed sensing; Intracranial; Undersampling

Mesh:

Year:  2017        PMID: 28785850      PMCID: PMC5803461          DOI: 10.1007/s10334-017-0646-8

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  47 in total

1.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

2.  In vivo assessment and visualization of intracranial arterial hemodynamics with flow-sensitized 4D MR imaging at 3T.

Authors:  S Wetzel; S Meckel; A Frydrychowicz; L Bonati; E-W Radue; K Scheffler; J Hennig; M Markl
Journal:  AJNR Am J Neuroradiol       Date:  2007-03       Impact factor: 3.825

3.  Assessment of flow and hemodynamics in the carotid artery using a reduced TE 4D flow spiral phase-contrast MRI.

Authors:  Mo Kadbi; Mj Negahdar; Melanie Traughber; Peter Martin; Amir A Amini
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2013

4.  Accelerated dual-venc 4D flow MRI for neurovascular applications.

Authors:  Susanne Schnell; Sameer A Ansari; Can Wu; Julio Garcia; Ian G Murphy; Ozair A Rahman; Amir A Rahsepar; Maria Aristova; Jeremy D Collins; James C Carr; Michael Markl
Journal:  J Magn Reson Imaging       Date:  2017-02-02       Impact factor: 4.813

5.  4D phase contrast MRI at 3 T: effect of standard and blood-pool contrast agents on SNR, PC-MRA, and blood flow visualization.

Authors:  Jelena Bock; Alex Frydrychowicz; Aurélien F Stalder; Thorsten A Bley; Hans Burkhardt; Jürgen Hennig; Michael Markl
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

6.  In vivo analysis of physiological 3D blood flow of cerebral veins.

Authors:  Florian Schuchardt; Laure Schroeder; Constantin Anastasopoulos; Michael Markl; Jochen Bäuerle; Anja Hennemuth; Johann Drexl; José M Valdueza; Irina Mader; Andreas Harloff
Journal:  Eur Radiol       Date:  2015-02-01       Impact factor: 5.315

7.  Evaluation of 4D vascular flow and tissue perfusion in cerebral arteriovenous malformations: influence of Spetzler-Martin grade, clinical presentation, and AVM risk factors.

Authors:  C Wu; S A Ansari; A R Honarmand; P Vakil; M C Hurley; B R Bendok; J Carr; T J Carroll; M Markl
Journal:  AJNR Am J Neuroradiol       Date:  2015-02-26       Impact factor: 3.825

8.  k-t BLAST and SENSE accelerated time-resolved three-dimensional phase contrast MRI in an intracranial aneurysm.

Authors:  Pim van Ooij; Annetje Guédon; Henk A Marquering; Joppe J Schneiders; Charles B Majoie; Ed van Bavel; Aart J Nederveen
Journal:  MAGMA       Date:  2012-09-07       Impact factor: 2.310

9.  Multi-dimensional flow-preserving compressed sensing (MuFloCoS) for time-resolved velocity-encoded phase contrast MRI.

Authors:  Jana Hutter; Peter Schmitt; Marc Saake; Axel Stubinger; Robert Grimm; Christoph Forman; Andreas Greiser; Joachim Hornegger; Andreas Maier
Journal:  IEEE Trans Med Imaging       Date:  2014-09-19       Impact factor: 10.048

10.  Aortic 4D flow: quantification of signal-to-noise ratio as a function of field strength and contrast enhancement for 1.5T, 3T, and 7T.

Authors:  Aaron T Hess; Malenka M Bissell; Ntobeko A B Ntusi; Andrew J M Lewis; Elizabeth M Tunnicliffe; Andreas Greiser; Aurelien F Stalder; Jane M Francis; Saul G Myerson; Stefan Neubauer; Matthew D Robson
Journal:  Magn Reson Med       Date:  2014-06-16       Impact factor: 4.668

View more
  11 in total

1.  Two-Minute k-Space and Time-accelerated Aortic Four-dimensional Flow MRI: Dual-Center Study of Feasibility and Impact on Velocity and Wall Shear Stress Quantification.

Authors:  Emilie Bollache; Kristopher D Knott; Kelly Jarvis; Redha Boubertakh; Ryan Scott Dolan; Claudia Camaioni; Louise Collins; Paul Scully; Sydney Rabin; Thomas Treibel; James C Carr; Pim van Ooij; Jeremy D Collins; Julia Geiger; James C Moon; Alex J Barker; Steffen E Petersen; Michael Markl
Journal:  Radiol Cardiothorac Imaging       Date:  2019-06-27

2.  Virtual injections using 4D flow MRI with displacement corrections and constrained probabilistic streamlines.

Authors:  Grant S Roberts; Michael W Loecher; Alma Spahic; Kevin M Johnson; Patrick A Turski; Laura B Eisenmenger; Oliver Wieben
Journal:  Magn Reson Med       Date:  2021-12-31       Impact factor: 4.668

3.  Fully automatic segmentation of 4D MRI for cardiac functional measurements.

Authors:  Yan Wang; Yue Zhang; Wanling Xuan; Evan Kao; Peng Cao; Bing Tian; Karen Ordovas; David Saloner; Jing Liu
Journal:  Med Phys       Date:  2018-11-20       Impact factor: 4.071

4.  Semi-automated analysis of 4D flow MRI to assess the hemodynamic impact of intracranial atherosclerotic disease.

Authors:  Alireza Vali; Maria Aristova; Parmede Vakil; Ramez Abdalla; Shyam Prabhakaran; Michael Markl; Sameer A Ansari; Susanne Schnell
Journal:  Magn Reson Med       Date:  2019-03-28       Impact factor: 4.668

5.  Associations between morphology and hemodynamics of intracranial aneurysms based on 4D flow and black-blood magnetic resonance imaging.

Authors:  Miaoqi Zhang; Fei Peng; Yunduo Li; Le He; Aihua Liu; Rui Li
Journal:  Quant Imaging Med Surg       Date:  2021-02

6.  Fetal Cerebral Oxygenation Is Impaired in Congenital Heart Disease and Shows Variable Response to Maternal Hyperoxia.

Authors:  Shabnam Peyvandi; Duan Xu; Yan Wang; Whitnee Hogan; Anita Moon-Grady; A James Barkovich; Orit Glenn; Patrick McQuillen; Jing Liu
Journal:  J Am Heart Assoc       Date:  2020-12-21       Impact factor: 5.501

7.  Influence of Spatial Resolution and Compressed SENSE Acceleration Factor on Flow Quantification with 4D Flow MRI at 3 Tesla.

Authors:  Mariya S Pravdivtseva; Franziska Gaidzik; Philipp Berg; Patricia Ulloa; Naomi Larsen; Olav Jansen; Jan-Bernd Hövener; Mona Salehi Ravesh
Journal:  Tomography       Date:  2022-02-10

Review 8.  Hemodynamics of Cerebral Aneurysms: Connecting Medical Imaging and Biomechanical Analysis.

Authors:  Vitaliy L Rayz; Aaron A Cohen-Gadol
Journal:  Annu Rev Biomed Eng       Date:  2020-03-25       Impact factor: 11.324

9.  Utilisation of advanced MRI techniques to understand neurovascular complications of PHACE syndrome: a case of arterial stenosis and dissection.

Authors:  Laura B Eisenmenger; Leonardo A Rivera-Rivera; Kevin M Johnson; Beth A Drolet
Journal:  BMJ Case Rep       Date:  2020-09-14

10.  Pseudo-spiral sampling and compressed sensing reconstruction provides flexibility of temporal resolution in accelerated aortic 4D flow MRI: A comparison with k-t principal component analysis.

Authors:  Lukas M Gottwald; Eva S Peper; Qinwei Zhang; Bram F Coolen; Gustav J Strijkers; Aart J Nederveen; Pim van Ooij
Journal:  NMR Biomed       Date:  2020-01-20       Impact factor: 4.044

View more