OBJECTIVE: The objective of this study was to investigate the performance of k-t BLAST (Broad-use Linear Acquisition Speed-up Technique) accelerated time-resolved 3D PC-MRI compared to SENSE (SENSitivity Encoding) acceleration in an in vitro and in vivo intracranial aneurysm. MATERIALS AND METHODS: Non-accelerated, SENSE and k-t BLAST accelerated time-resolved 3D PC-MRI measurements were performed in vivo and in vitro. We analysed the consequences of various temporal resolutions in vitro. RESULTS: Both in vitro and in vivo measurements showed that the main effect of k-t BLAST was underestimation of velocity during systole. In the phantom, temporal blurring decreased with increasing temporal resolution. Quantification of the differences between the non-accelerated and accelerated measurements confirmed that in systole SENSE performed better than k-t BLAST in terms of mean velocity magnitude. In both in vitro and in vivo measurements, k-t BLAST had higher SNR compared to SENSE. Qualitative comparison between measurements showed good similarity. CONCLUSION: Comparison with SENSE revealed temporal blurring effects in k-t BLAST accelerated measurements.
OBJECTIVE: The objective of this study was to investigate the performance of k-t BLAST (Broad-use Linear Acquisition Speed-up Technique) accelerated time-resolved 3D PC-MRI compared to SENSE (SENSitivity Encoding) acceleration in an in vitro and in vivo intracranial aneurysm. MATERIALS AND METHODS: Non-accelerated, SENSE and k-t BLAST accelerated time-resolved 3D PC-MRI measurements were performed in vivo and in vitro. We analysed the consequences of various temporal resolutions in vitro. RESULTS: Both in vitro and in vivo measurements showed that the main effect of k-t BLAST was underestimation of velocity during systole. In the phantom, temporal blurring decreased with increasing temporal resolution. Quantification of the differences between the non-accelerated and accelerated measurements confirmed that in systole SENSE performed better than k-t BLAST in terms of mean velocity magnitude. In both in vitro and in vivo measurements, k-t BLAST had higher SNR compared to SENSE. Qualitative comparison between measurements showed good similarity. CONCLUSION: Comparison with SENSE revealed temporal blurring effects in k-t BLAST accelerated measurements.
Authors: Jing Liu; Louise Koskas; Farshid Faraji; Evan Kao; Yan Wang; Henrik Haraldsson; Sarah Kefayati; Chengcheng Zhu; Sinyeob Ahn; Gerhard Laub; David Saloner Journal: MAGMA Date: 2017-08-07 Impact factor: 2.310
Authors: M Markl; S Schnell; C Wu; E Bollache; K Jarvis; A J Barker; J D Robinson; C K Rigsby Journal: Clin Radiol Date: 2016-03-02 Impact factor: 2.350