Literature DB >> 24109884

Assessment of flow and hemodynamics in the carotid artery using a reduced TE 4D flow spiral phase-contrast MRI.

Mo Kadbi, Mj Negahdar, Melanie Traughber, Peter Martin, Amir A Amini.   

Abstract

4D flow MRI is a powerful technique for quantitative flow assessment and visualization of complex flow patterns and hemodynamics of cardiovascular flows. This technique results in more anatomical information and comprehensive assessment of blood flow. However, conventional 4D PC MRI suffers from a few obstacles for clinical applications. The total scan time is long, especially in large volumes with high spatial resolutions. Inaccuracy of conventional Cartesian PC MRI in the setting of atherosclerosis and in general, disturbed and turbulent blood flow is another important challenge. This inaccuracy is the consequence of signal loss, intravoxel dephasing and flow-related artifact in the presence of disturbed and turbulent flow. Spiral k-space trajectory has valuable attributes which can help overcome some of the problems with 4D flow Cartesian acquisitions. Spiral trajectory benefits from shorter TE and reduces the flow-related artifacts. In addition, short spiral readouts with spiral interleaves can significantly reduce the total scan time, reducing the chances of patient motion which may also corrupt the data in the form of motion artifacts. In this paper, the accuracy of flow assessment and flow visualization with reduced TE 4D Spiral PC was investigated and good agreement was observed between the spiral and conventional technique. The systolic mean velocity, peak flow and the average flow in CCA and ICA of normal volunteers using 4D spiral PC MRI showed errors less than 10% compared to conventional 4D PC MRI. In addition, the scan time using spiral sequence was 3∶31 min which is half of the time using conventional sequence.

Entities:  

Mesh:

Year:  2013        PMID: 24109884     DOI: 10.1109/EMBC.2013.6609697

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  5 in total

1.  Highly accelerated intracranial 4D flow MRI: evaluation of healthy volunteers and patients with intracranial aneurysms.

Authors:  Jing Liu; Louise Koskas; Farshid Faraji; Evan Kao; Yan Wang; Henrik Haraldsson; Sarah Kefayati; Chengcheng Zhu; Sinyeob Ahn; Gerhard Laub; David Saloner
Journal:  MAGMA       Date:  2017-08-07       Impact factor: 2.310

Review 2.  Advanced flow MRI: emerging techniques and applications.

Authors:  M Markl; S Schnell; C Wu; E Bollache; K Jarvis; A J Barker; J D Robinson; C K Rigsby
Journal:  Clin Radiol       Date:  2016-03-02       Impact factor: 2.350

Review 3.  Four-dimensional MRI flow examinations in cerebral and extracerebral vessels - ready for clinical routine?

Authors:  Susanne Schnell; Can Wu; Sameer A Ansari
Journal:  Curr Opin Neurol       Date:  2016-08       Impact factor: 5.710

4.  Cardiac 4D phase-contrast CMR at 9.4 T using self-gated ultra-short echo time (UTE) imaging.

Authors:  M Krämer; A G Motaal; K-H Herrmann; B Löffler; J R Reichenbach; G J Strijkers; V Hoerr
Journal:  J Cardiovasc Magn Reson       Date:  2017-03-31       Impact factor: 5.364

5.  Retrospectively gated intracardiac 4D flow MRI using spiral trajectories.

Authors:  Sven Petersson; Andreas Sigfridsson; Petter Dyverfeldt; Carl-Johan Carlhäll; Tino Ebbers
Journal:  Magn Reson Med       Date:  2015-02-13       Impact factor: 4.668

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.