Literature DB >> 28767366

Detector Blur and Correlated Noise Modeling for Digital Breast Tomosynthesis Reconstruction.

Jiabei Zheng, Jeffrey A Fessler, Heang-Ping Chan.   

Abstract

This paper describes a new image reconstruction method for digital breast tomosynthesis (DBT). The new method incorporates detector blur into the forward model. The detector blur in DBT causes correlation in the measurement noise. By making a few approximations that are reasonable for breast imaging, we formulated a regularized quadratic optimization problem with a data-fit term that incorporates models for detector blur and correlated noise (DBCN). We derived a computationally efficient separable quadratic surrogate (SQS) algorithm to solve the optimization problem that has a non-diagonal noise covariance matrix. We evaluated the SQS-DBCN method by reconstructing DBT scans of breast phantoms and human subjects. The contrast-to-noise ratio and sharpness of microcalcifications were analyzed and compared with those by the simultaneous algebraic reconstruction technique. The quality of soft tissue lesions and parenchymal patterns was examined. The results demonstrate the potential to improve the image quality of reconstructed DBT images by incorporating the system physics model. This paper is a first step toward model-based iterative reconstruction for DBT.

Entities:  

Mesh:

Year:  2017        PMID: 28767366      PMCID: PMC5772655          DOI: 10.1109/TMI.2017.2732824

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  37 in total

1.  Task-based performance analysis of FBP, SART and ML for digital breast tomosynthesis using signal CNR and Channelised Hotelling Observers.

Authors:  Dominique Van de Sompel; Sir Michael Brady; John Boone
Journal:  Med Image Anal       Date:  2010-07-27       Impact factor: 8.545

2.  A method for measuring the presampled MTF of digital radiographic systems using an edge test device.

Authors:  E Samei; M J Flynn; D A Reimann
Journal:  Med Phys       Date:  1998-01       Impact factor: 4.071

3.  Multiscale bilateral filtering for improving image quality in digital breast tomosynthesis.

Authors:  Yao Lu; Heang-Ping Chan; Jun Wei; Lubomir M Hadjiiski; Ravi K Samala
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

Review 4.  A review of breast tomosynthesis. Part II. Image reconstruction, processing and analysis, and advanced applications.

Authors:  Ioannis Sechopoulos
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

5.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

6.  Digital breast tomosynthesis: observer performance of clustered microcalcification detection on breast phantom images acquired with an experimental system using variable scan angles, angular increments, and number of projection views.

Authors:  Heang-Ping Chan; Mitchell M Goodsitt; Mark A Helvie; Scott Zelakiewicz; Andrea Schmitz; Mitra Noroozian; Chintana Paramagul; Marilyn A Roubidoux; Alexis V Nees; Colleen H Neal; Paul Carson; Yao Lu; Lubomir Hadjiiski; Jun Wei
Journal:  Radiology       Date:  2014-07-07       Impact factor: 11.105

7.  Ordered subsets algorithms for transmission tomography.

Authors:  H Erdogan; J A Fessler
Journal:  Phys Med Biol       Date:  1999-11       Impact factor: 3.609

8.  Segmented separable footprint projector for digital breast tomosynthesis and its application for subpixel reconstruction.

Authors:  Jiabei Zheng; Jeffrey A Fessler; Heang-Ping Chan
Journal:  Med Phys       Date:  2017-03       Impact factor: 4.071

9.  Quadratic regularization design for 2-D CT.

Authors:  Hugo R Shi; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2008-10-31       Impact factor: 10.048

10.  Accelerating ordered subsets image reconstruction for X-ray CT using spatially nonuniform optimization transfer.

Authors:  Donghwan Kim; Debashish Pal; Jean-Baptiste Thibault; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2013-06-07       Impact factor: 10.048

View more
  8 in total

1.  Penalized-Likelihood Reconstruction With High-Fidelity Measurement Models for High-Resolution Cone-Beam Imaging.

Authors:  Steven Tilley; Matthew Jacobson; Qian Cao; Michael Brehler; Alejandro Sisniega; Wojciech Zbijewski; J Webster Stayman
Journal:  IEEE Trans Med Imaging       Date:  2018-04       Impact factor: 10.048

2.  Statistical CT reconstruction using region-aware texture preserving regularization learning from prior normal-dose CT image.

Authors:  Xiao Jia; Yuting Liao; Dong Zeng; Hao Zhang; Yuanke Zhang; Ji He; Zhaoying Bian; Yongbo Wang; Xi Tao; Zhengrong Liang; Jing Huang; Jianhua Ma
Journal:  Phys Med Biol       Date:  2018-11-20       Impact factor: 3.609

3.  Blind deconvolution in model-based iterative reconstruction for CT using a normalized sparsity measure.

Authors:  Lorenz Hehn; Steven Tilley; Franz Pfeiffer; J Webster Stayman
Journal:  Phys Med Biol       Date:  2019-10-31       Impact factor: 3.609

4.  Effect of source blur on digital breast tomosynthesis reconstruction.

Authors:  Jiabei Zheng; Jeffrey A Fessler; Heang-Ping Chan
Journal:  Med Phys       Date:  2019-10-20       Impact factor: 4.071

5.  Predicting image properties in penalized-likelihood reconstructions of flat-panel CBCT.

Authors:  Wenying Wang; Grace J Gang; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Med Phys       Date:  2018-11-20       Impact factor: 4.071

6.  Deep Convolutional Neural Network With Adversarial Training for Denoising Digital Breast Tomosynthesis Images.

Authors:  Mingjie Gao; Jeffrey A Fessler; Heang-Ping Chan
Journal:  IEEE Trans Med Imaging       Date:  2021-06-30       Impact factor: 11.037

7.  Evaluation of a Generative Adversarial Network to Improve Image Quality and Reduce Radiation-Dose during Digital Breast Tomosynthesis.

Authors:  Tsutomu Gomi; Yukie Kijima; Takayuki Kobayashi; Yukio Koibuchi
Journal:  Diagnostics (Basel)       Date:  2022-02-14

8.  Reduced anatomical clutter in digital breast tomosynthesis with statistical iterative reconstruction.

Authors:  John W Garrett; Yinsheng Li; Ke Li; Guang-Hong Chen
Journal:  Med Phys       Date:  2018-04-01       Impact factor: 4.071

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.