Literature DB >> 23751959

Accelerating ordered subsets image reconstruction for X-ray CT using spatially nonuniform optimization transfer.

Donghwan Kim, Debashish Pal, Jean-Baptiste Thibault, Jeffrey A Fessler.   

Abstract

Statistical image reconstruction algorithms in X-ray computed tomography (CT) provide improved image quality for reduced dose levels but require substantial computation time. Iterative algorithms that converge in few iterations and that are amenable to massive parallelization are favorable in multiprocessor implementations. The separable quadratic surrogate (SQS) algorithm is desirable as it is simple and updates all voxels simultaneously. However, the standard SQS algorithm requires many iterations to converge. This paper proposes an extension of the SQS algorithm that leads to spatially nonuniform updates. The nonuniform (NU) SQS encourages larger step sizes for the voxels that are expected to change more between the current and the final image, accelerating convergence, while the derivation of NU-SQS guarantees monotonic descent. Ordered subsets (OS) algorithms can also accelerate SQS, provided suitable "subset balance" conditions hold. These conditions can fail in 3-D helical cone-beam CT due to incomplete sampling outside the axial region-of-interest (ROI). This paper proposes a modified OS algorithm that is more stable outside the ROI in helical CT. We use CT scans to demonstrate that the proposed NU-OS-SQS algorithm handles the helical geometry better than the conventional OS methods and "converges" in less than half the time of ordinary OS-SQS.

Entities:  

Mesh:

Year:  2013        PMID: 23751959      PMCID: PMC3818426          DOI: 10.1109/TMI.2013.2266898

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  26 in total

1.  A solution to the long-object problem in helical cone-beam tomography.

Authors:  M Defrise; F Noo; H Kudo
Journal:  Phys Med Biol       Date:  2000-03       Impact factor: 3.609

2.  Region of interest reconstruction from truncated data in circular cone-beam CT.

Authors:  Lifeng Yu; Yu Zou; Emil Y Sidky; Charles A Pelizzari; Peter Munro; Xiaochuan Pan
Journal:  IEEE Trans Med Imaging       Date:  2006-07       Impact factor: 10.048

3.  A modified expectation maximization algorithm for penalized likelihood estimation in emission tomography.

Authors:  A R De Pierro
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

4.  On the Convergence of the Iterative Image Space Reconstruction Algorithm for Volume ECT.

Authors: 
Journal:  IEEE Trans Med Imaging       Date:  1987       Impact factor: 10.048

5.  A three-dimensional statistical approach to improved image quality for multislice helical CT.

Authors:  Jean-Baptiste Thibault; Ken D Sauer; Charles A Bouman; Jiang Hsieh
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

6.  Iterative reconstruction for helical CT: a simulation study.

Authors:  J Nuyts; B De Man; P Dupont; M Defrise; P Suetens; L Mortelmans
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

7.  Grouped-coordinate ascent algorithms for penalized-likelihood transmission image reconstruction.

Authors:  J A Fessler; E P Ficaro; N H Clinthorne; K Lange
Journal:  IEEE Trans Med Imaging       Date:  1997-04       Impact factor: 10.048

8.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

9.  Ordered subsets algorithms for transmission tomography.

Authors:  H Erdogan; J A Fessler
Journal:  Phys Med Biol       Date:  1999-11       Impact factor: 3.609

10.  A splitting-based iterative algorithm for accelerated statistical X-ray CT reconstruction.

Authors:  Sathish Ramani; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2011-11-08       Impact factor: 10.048

View more
  18 in total

1.  Nonuniform update for sparse target recovery in fluorescence molecular tomography accelerated by ordered subsets.

Authors:  Dianwen Zhu; Changqing Li
Journal:  Biomed Opt Express       Date:  2014-11-12       Impact factor: 3.732

2.  Time of flight PET reconstruction using nonuniform update for regional recovery uniformity.

Authors:  Kyungsang Kim; Donghwan Kim; Jaewon Yang; Georges El Fakhri; Youngho Seo; Jeffrey A Fessler; Quanzheng Li
Journal:  Med Phys       Date:  2019-01-04       Impact factor: 4.071

3.  Accelerated statistical reconstruction for C-arm cone-beam CT using Nesterov's method.

Authors:  Adam S Wang; J Webster Stayman; Yoshito Otake; Sebastian Vogt; Gerhard Kleinszig; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

4.  Metal artifact correction for x-ray computed tomography using kV and selective MV imaging.

Authors:  Meng Wu; Andreas Keil; Dragos Constantin; Josh Star-Lack; Lei Zhu; Rebecca Fahrig
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

5.  A comparison of linear interpolation models for iterative CT reconstruction.

Authors:  Katharina Hahn; Harald Schöndube; Karl Stierstorfer; Joachim Hornegger; Frédéric Noo
Journal:  Med Phys       Date:  2016-12       Impact factor: 4.071

6.  Comparison of SIRT and SQS for Regularized Weighted Least Squares Image Reconstruction.

Authors:  Jens Gregor; Jeffrey A Fessler
Journal:  IEEE Trans Comput Imaging       Date:  2015-06-05

7.  Accelerated fast iterative shrinkage thresholding algorithms for sparsity-regularized cone-beam CT image reconstruction.

Authors:  Qiaofeng Xu; Deshan Yang; Jun Tan; Alex Sawatzky; Mark A Anastasio
Journal:  Med Phys       Date:  2016-04       Impact factor: 4.071

8.  Impact of the non-negativity constraint in model-based iterative reconstruction from CT data.

Authors:  Viktor Haase; Katharina Hahn; Harald Schöndube; Karl Stierstorfer; Andreas Maier; Frédéric Noo
Journal:  Med Phys       Date:  2019-12       Impact factor: 4.071

9.  Multi-material decomposition using statistical image reconstruction for spectral CT.

Authors:  Yong Long; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2014-04-25       Impact factor: 10.048

10.  Statistical reconstruction for cone-beam CT with a post-artifact-correction noise model: application to high-quality head imaging.

Authors:  H Dang; J W Stayman; A Sisniega; J Xu; W Zbijewski; X Wang; D H Foos; N Aygun; V E Koliatsos; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2015-07-30       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.