Literature DB >> 30372536

Predicting image properties in penalized-likelihood reconstructions of flat-panel CBCT.

Wenying Wang1, Grace J Gang1, Jeffrey H Siewerdsen1, J Webster Stayman1.   

Abstract

PURPOSE: Model-based iterative reconstruction (MBIR) algorithms such as penalized-likelihood (PL) methods exhibit data-dependent and shift-variant properties. Image quality predictors have been derived to prospectively estimate local noise and spatial resolution, facilitating both system hardware design and tuning of reconstruction methods. However, current MBIR image quality predictors rely on idealized system models, ignoring physical blurring effects and noise correlations found in real systems. In this work, we develop and validate a new set of predictors using a physical system model specific to flat-panel cone-beam CT (FP-CBCT).
METHODS: Physical models appropriate for integration with MBIR analysis are developed and parameterized to represent nonidealities in FP projection data including focal spot blur, scintillator blur, detector aperture effect, and noise correlations. Flat-panel-specific predictors for local spatial resolution and local noise properties in PL reconstructions are developed based on these realistic physical models. Estimation accuracy of conventional (idealized) and FP-specific predictors is investigated and validated against experimental CBCT measurements using specialized phantoms.
RESULTS: Validation studies show that flat-panel-specific predictors can accurately estimate the local spatial resolution and noise properties, while conventional predictors show significant deviations in the magnitude and scale of the spatial resolution and local noise. The proposed predictors show accurate estimations over a range of imaging conditions including varying x-ray technique and regularization strength. The conventional spatial resolution prediction is sharper than ground truth. Using conventional spatial resolution predictor, the full width at half maximum (FWHM) of local point spread function (PSF) is underestimated by 0.2 mm. This mismatch is mostly eliminated in FP-specific prediction. The general shape and amplitude of local noise power spectrum (NPS) FP-specific predictions are consistent with measurement, while the conventional predictions underestimated the noise level by 70%.
CONCLUSION: The proposed image quality predictors permit accurate estimation of local spatial resolution and noise properties for PL reconstruction, accounting for dependencies on the system geometry, x-ray technique, and patient-specific anatomy in real FP-CBCT. Such tools enable prospective analysis of image quality for a range of goals including novel system and acquisition design, adaptive and task-driven imaging, and tuning of MBIR for robust and reliable behavior.
© 2018 American Association of Physicists in Medicine.

Entities:  

Keywords:  CT image quality; flat-panel cone-beam CT; local point spread function; model-based iterative reconstruction; noise power spectrum

Mesh:

Year:  2018        PMID: 30372536      PMCID: PMC6904934          DOI: 10.1002/mp.13249

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  63 in total

1.  Monotonic algorithms for transmission tomography.

Authors:  H Erdoğan; J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  1999-09       Impact factor: 10.048

2.  Anatomical background and generalized detectability in tomosynthesis and cone-beam CT.

Authors:  G J Gang; D J Tward; J Lee; J H Siewerdsen
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

3.  Generalized DQE analysis of radiographic and dual-energy imaging using flat-panel detectors.

Authors:  S Richard; J H Siewerdsen; D A Jaffray; D J Moseley; B Bakhtiar
Journal:  Med Phys       Date:  2005-05       Impact factor: 4.071

4.  Clinical applications of cone-beam computed tomography in dental practice.

Authors:  William C Scarfe; Allan G Farman; Predag Sukovic
Journal:  J Can Dent Assoc       Date:  2006-02       Impact factor: 1.316

Review 5.  Cone Beam Computed Tomography (CBCT) in the Field of Interventional Oncology of the Liver.

Authors:  Blanche Bapst; Matthieu Lagadec; Romain Breguet; Valérie Vilgrain; Maxime Ronot
Journal:  Cardiovasc Intervent Radiol       Date:  2015-07-16       Impact factor: 2.740

6.  Iterative reconstruction techniques for computed tomography Part 1: technical principles.

Authors:  Martin J Willemink; Pim A de Jong; Tim Leiner; Linda M de Heer; Rutger A J Nievelstein; Ricardo P J Budde; Arnold M R Schilham
Journal:  Eur Radiol       Date:  2013-01-12       Impact factor: 5.315

7.  Fast Variance Prediction for Iteratively Reconstructed CT Images With Locally Quadratic Regularization.

Authors:  Stephen M Schmitt; Mitchell M Goodsitt; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2016-07-19       Impact factor: 10.048

8.  Model-based iterative reconstruction for flat-panel cone-beam CT with focal spot blur, detector blur, and correlated noise.

Authors:  Steven Tilley; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Phys Med Biol       Date:  2015-12-09       Impact factor: 3.609

Review 9.  Modelling the physics in the iterative reconstruction for transmission computed tomography.

Authors:  Johan Nuyts; Bruno De Man; Jeffrey A Fessler; Wojciech Zbijewski; Freek J Beekman
Journal:  Phys Med Biol       Date:  2013-06-05       Impact factor: 3.609

Review 10.  Micro-CT of rodents: state-of-the-art and future perspectives.

Authors:  D P Clark; C T Badea
Journal:  Phys Med       Date:  2014-06-26       Impact factor: 2.685

View more
  2 in total

1.  Convergence criterion for MBIR based on the local noise-power spectrum: Theory and implementation in a framework for accelerated 3D image reconstruction with a morphological pyramid.

Authors:  A Sisniega; J W Stayman; S Capostagno; C R Weiss; T Ehtiati; J H Siewerdsen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2019-05-28

2.  Local response prediction in model-based CT material decomposition.

Authors:  Wenying Wang; Steven Tilley; Matthew Tivnan; J Webster Stayman
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2019-05-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.