Low dose megavoltage cone beam computed tomography with an unflattened 4 MV beam from a carbon target.

Bruce A Faddegon1, Vincent Wu, Jean Pouliot, Bijumon Gangadharan, Ali Bani-Hashemi.   

Abstract

Megavoltage cone beam computed tomography (MVCBCT) is routinely used for visualizing anatomical structures and implanted fiducials for patient positioning in radiotherapy. MVCBCT using a 6 MV treatment beam with high atomic number (Z) target and flattening filter in the beamline, as done conventionally, has lower image quality than can be achieved with a MV beam due to heavy filtration of the low-energy bremsstrahlung. The unflattened beam of a low Z target has an abundance of diagnostic energy photons, detected with modern flat panel detectors with much higher efficiency given the same dose to the patient. This principle guided the development of a new megavoltage imaging beamline (IBL) for a commercial radiotherapy linear accelerator. A carbon target was placed in one of the electron primary scattering foil slots on the target-foil slide. A PROM on a function controller board was programed to put the carbon target in place for MVCBCT. A low accelerating potential of 4.2 MV was used for the IBL to restrict leakage of primary electrons through the target such that dose from x rays dominated the signal in the monitor chamber and the patient surface dose. Results from phantom and cadaver images demonstrated that the IBL had much improved image quality over the treatment beam. For similar imaging dose, the IBL improved the contrast-to-noise ratio by as much as a factor of 3 in soft tissue over that of the treatment beam. The IBL increased the spatial resolution by about a factor of 2, allowing the visualization of finer anatomical details. Images of the cadaver contained useful information with doses as low as 1 cGy. The IBL may be installed on certain models of linear accelerators without mechanical modification and results in significant improvement in the image quality with the same dose, or images of the same quality with less than one-third of the dose.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19175135     DOI: 10.1118/1.3013571

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  29 in total

1.  Super-resolution imaging in a multiple layer EPID.

Authors:  Haijian Chen; Joerg Rottmann; Stephen Sf Yip; Daniel Morf; Rony Füglistaller; Josh Star-Lack; George Zentai; Ross Berbeco
Journal:  Biomed Phys Eng Express       Date:  2017-02-21

2.  Determination of electron energy, spectral width, and beam divergence at the exit window for clinical megavoltage x-ray beams.

Authors:  D L Sawkey; B A Faddegon
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

3.  Dosimetric properties and commissioning of cone-beam CT image beam line with a carbon target.

Authors:  Y Dzierma; F G Nuesken; N P Licht; C Ruebe
Journal:  Strahlenther Onkol       Date:  2013-05-30       Impact factor: 3.621

4.  Treatment head disassembly to improve the accuracy of large electron field simulation.

Authors:  Bruce A Faddegon; Daren Sawkey; Tuathan O'Shea; Malcolm McEwen; Carl Ross
Journal:  Med Phys       Date:  2009-10       Impact factor: 4.071

5.  Comparison between manual and automatic image registration in image-guided radiation therapy using megavoltage cone-beam computed tomography with an imaging beam line for prostate cancer.

Authors:  Takashi Hashido; Shinya Nakasone; Mari Fukao; Seiichi Ota; Shinichi Inoue
Journal:  Radiol Phys Technol       Date:  2018-09-21

6.  Dosimetric consequences of rotational errors in radiation therapy of pediatric brain tumor patients.

Authors:  Chris Beltran; Alexander Pegram; Thomas E Merchant
Journal:  Radiother Oncol       Date:  2011-07-02       Impact factor: 6.280

7.  [Organizational models of inpatient emergency and acute care].

Authors:  A Kaltwasser; C Dodt
Journal:  Med Klin Intensivmed Notfmed       Date:  2014-10       Impact factor: 0.840

8.  Optimization of the design of thick, segmented scintillators for megavoltage cone-beam CT using a novel, hybrid modeling technique.

Authors:  Langechuan Liu; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Hao Jiang
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

9.  Low-dose megavoltage cone-beam computed tomography using a novel multi-layer imager (MLI).

Authors:  Marios Myronakis; Pascal Huber; Mathias Lehmann; Rony Fueglistaller; Matthew Jacobson; Yue-Houng Hu; Paul Baturin; Adam Wang; Mengying Shi; Thomas Harris; Daniel Morf; Ross Berbeco
Journal:  Med Phys       Date:  2020-01-28       Impact factor: 4.071

10.  The accuracy of EGSnrc, Geant4 and PENELOPE Monte Carlo systems for the simulation of electron scatter in external beam radiotherapy.

Authors:  Bruce A Faddegon; Iwan Kawrakow; Yuri Kubyshin; Joseph Perl; Josep Sempau; Laszlo Urban
Journal:  Phys Med Biol       Date:  2009-09-24       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.