Hybrid spectral CT reconstruction.

Darin P Clark1, Cristian T Badea1.   

Abstract

Current photon counting x-ray detector (PCD) technology faces limitations associated with spectral fidelity and photon starvation. One strategy for addressing these limitations is to supplement PCD data with high-resolution, low-noise data acquired with an energy-integrating detector (EID). In this work, we propose an iterative, hybrid reconstruction technique which combines the spectral properties of PCD data with the resolution and signal-to-noise characteristics of EID data. Our hybrid reconstruction technique is based on an algebraic model of data fidelity which substitutes the EID data into the data fidelity term associated with the PCD reconstruction, resulting in a joint reconstruction problem. Within the split Bregman framework, these data fidelity constraints are minimized subject to additional constraints on spectral rank and on joint intensity-gradient sparsity measured between the reconstructions of the EID and PCD data. Following a derivation of the proposed technique, we apply it to the reconstruction of a digital phantom which contains realistic concentrations of iodine, barium, and calcium encountered in small-animal micro-CT. The results of this experiment suggest reliable separation and detection of iodine at concentrations ≥ 5 mg/ml and barium at concentrations ≥ 10 mg/ml in 2-mm features for EID and PCD data reconstructed with inherent spatial resolutions of 176 μm and 254 μm, respectively (point spread function, FWHM). Furthermore, hybrid reconstruction is demonstrated to enhance spatial resolution within material decomposition results and to improve low-contrast detectability by as much as 2.6 times relative to reconstruction with PCD data only. The parameters of the simulation experiment are based on an in vivo micro-CT experiment conducted in a mouse model of soft-tissue sarcoma. Material decomposition results produced from this in vivo data demonstrate the feasibility of distinguishing two K-edge contrast agents with a spectral separation on the order of the energy resolution of the PCD hardware.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28683124      PMCID: PMC5500339          DOI: 10.1371/journal.pone.0180324

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


  50 in total

1.  Statistical image reconstruction for polyenergetic X-ray computed tomography.

Authors:  Idris A Elbakri; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2002-02       Impact factor: 10.048

Review 2.  The enhanced permeability and retention (EPR) effect in tumor vasculature: the key role of tumor-selective macromolecular drug targeting.

Authors:  H Maeda
Journal:  Adv Enzyme Regul       Date:  2001

3.  Cone-beam reprojection using projection-matrices.

Authors:  Ramesh R Galigekere; Karl Wiesent; David W Holdsworth
Journal:  IEEE Trans Med Imaging       Date:  2003-10       Impact factor: 10.048

4.  Fast and robust multiframe super resolution.

Authors:  Sina Farsiu; M Dirk Robinson; Michael Elad; Peyman Milanfar
Journal:  IEEE Trans Image Process       Date:  2004-10       Impact factor: 10.856

5.  A spatially and temporally restricted mouse model of soft tissue sarcoma.

Authors:  David G Kirsch; Daniela M Dinulescu; John B Miller; Jan Grimm; Philip M Santiago; Nathan P Young; G Petur Nielsen; Bradley J Quade; Christopher J Chaber; Christian P Schultz; Osamu Takeuchi; Roderick T Bronson; Denise Crowley; Stanley J Korsmeyer; Sam S Yoon; Francis J Hornicek; Ralph Weissleder; Tyler Jacks
Journal:  Nat Med       Date:  2007-08-05       Impact factor: 53.440

6.  Spektr: a computational tool for x-ray spectral analysis and imaging system optimization.

Authors:  J H Siewerdsen; A M Waese; D J Moseley; S Richard; D A Jaffray
Journal:  Med Phys       Date:  2004-11       Impact factor: 4.071

7.  The phantom portion of the American College of Radiology (ACR) computed tomography (CT) accreditation program: practical tips, artifact examples, and pitfalls to avoid.

Authors:  Cynthia H McCollough; Michael R Bruesewitz; Michael F McNitt-Gray; Krista Bush; Thomas Ruckdeschel; J Thomas Payne; James A Brink; Robert K Zeman
Journal:  Med Phys       Date:  2004-09       Impact factor: 4.071

8.  Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography.

Authors:  Jing Wang; Tianfang Li; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Med Imaging       Date:  2006-10       Impact factor: 10.048

9.  The PILATUS 1M detector.

Authors:  Ch Broennimann; E F Eikenberry; B Henrich; R Horisberger; G Huelsen; E Pohl; B Schmitt; C Schulze-Briese; M Suzuki; T Tomizaki; H Toyokawa; A Wagner
Journal:  J Synchrotron Radiat       Date:  2006-02-17       Impact factor: 2.616

10.  A liposomal nanoscale contrast agent for preclinical CT in mice.

Authors:  Srinivasan Mukundan; Ketan B Ghaghada; Cristian T Badea; Chen-Yu Kao; Laurence W Hedlund; James M Provenzale; G Allan Johnson; Emmanuel Chen; Ravi V Bellamkonda; Ananth Annapragada
Journal:  AJR Am J Roentgenol       Date:  2006-02       Impact factor: 3.959

View more
  10 in total

1.  Overcoming detector limitations of x-ray photon counting for preclinical microcomputed tomography.

Authors:  Matthew Holbrook; Darin P Clark; Cristian T Badea
Journal:  J Med Imaging (Bellingham)       Date:  2018-08-24

2.  Low-dose 4D cardiac imaging in small animals using dual source micro-CT.

Authors:  M Holbrook; D P Clark; C T Badea
Journal:  Phys Med Biol       Date:  2018-01-09       Impact factor: 3.609

3.  Dual source hybrid spectral micro-CT using an energy-integrating and a photon-counting detector.

Authors:  M D Holbrook; D P Clark; C T Badea
Journal:  Phys Med Biol       Date:  2020-10-21       Impact factor: 3.609

4.  Evaluating renal lesions using deep-learning based extension of dual-energy FoV in dual-source CT-A retrospective pilot study.

Authors:  Fides R Schwartz; Darin P Clark; Yuqin Ding; Juan Carlos Ramirez-Giraldo; Cristian T Badea; Daniele Marin
Journal:  Eur J Radiol       Date:  2021-04-24       Impact factor: 4.531

Review 5.  Advances in micro-CT imaging of small animals.

Authors:  D P Clark; C T Badea
Journal:  Phys Med       Date:  2021-07-17       Impact factor: 3.119

6.  Multicolour imaging with spectral photon-counting CT: a phantom study.

Authors:  Salim Si-Mohamed; Daniel Bar-Ness; Monica Sigovan; Valérie Tatard-Leitman; David P Cormode; Pratap C Naha; Philippe Coulon; Lucie Rascle; Ewald Roessl; Michal Rokni; Ami Altman; Yoad Yagil; Loic Boussel; Philippe Douek
Journal:  Eur Radiol Exp       Date:  2018-10-17

7.  Photon-counting cine-cardiac CT in the mouse.

Authors:  Darin P Clark; Matthew Holbrook; Chang-Lung Lee; Cristian T Badea
Journal:  PLoS One       Date:  2019-09-19       Impact factor: 3.240

8.  Performance of sparse-view CT reconstruction with multi-directional gradient operators.

Authors:  Chia-Jui Hsieh; Shih-Chun Jin; Jyh-Cheng Chen; Chih-Wei Kuo; Ruei-Teng Wang; Woei-Chyn Chu
Journal:  PLoS One       Date:  2019-01-07       Impact factor: 3.240

9.  Photon Counting CT and Radiomic Analysis Enables Differentiation of Tumors Based on Lymphocyte Burden.

Authors:  Alex J Allphin; Yvonne M Mowery; Kyle J Lafata; Darin P Clark; Alex M Bassil; Rico Castillo; Diana Odhiambo; Matthew D Holbrook; Ketan B Ghaghada; Cristian T Badea
Journal:  Tomography       Date:  2022-03-10

10.  Functional imaging of tumor vasculature using iodine and gadolinium-based nanoparticle contrast agents: a comparison of spectral micro-CT using energy integrating and photon counting detectors.

Authors:  C T Badea; D P Clark; M Holbrook; M Srivastava; Y Mowery; K B Ghaghada
Journal:  Phys Med Biol       Date:  2019-03-12       Impact factor: 3.609

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.