Temporary anchorage device stability: an evaluation of thread shape factor.

M Migliorati1, A Signori, A Silvestrini-Biavati.   

Abstract

The resistance to extraction of temporary anchorage devices (TADs) depends on various factors, including miniscrew design, shear strength, and bone density. This research introduces the thread shape factor (TSF) as a new factor for the evaluation of TAD mechanical properties. The authors evaluated three TADs for a total of 27 tests: Mini-impianto autoforante (Leone, 1.75 mm diameter and 8 mm length), Orthoscrew (Leader Ortodonzia, 1.65 mm diameter and 9 mm length), and MAS (Miniscrew Anchorage System, 1.3 mm diameter and 11 mm length). For each TAD, the images were acquired via a 20.00 kV scanning electron microscopy to measure their respective mean depth of thread (D), pitch (P), and the relationship between the two (TSF). Subsequently, pullout tests on organic bone analogue were carried out using a testing machine; a crosshead speed of 2 mm/minutes was applied. A two-way analysis of variance was performed to evaluate the interaction between the type of miniscrew and the cortical thickness. A post hoc analysis for single comparisons was subsequently employed. In addition, if homogeneity of variances was not rejected, Scheffè's test was performed, while Tamhane's test was carried out if the homogeneity of variance assumption was not met. Univariate linear regression models were fitted to evaluate the relationship between the outcomes and TSF, D, and P separately. A P value of 0.05 was considered statistically significant. From univariate linear regression, TSF, D, and P were statistically significant predictors of 'peak load'. The tests showed that TSF has a statistical significance for describing the mechanical competency of TADs.

Mesh:

Year:  2011        PMID: 21367816     DOI: 10.1093/ejo/cjr026

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  10 in total

1.  Does Change in Thread Shape Influence the Pull Out Strength of Mini Implants? An In vitro Study.

Authors:  Aniruddh V Yashwant; S Dilip; R Krishnaraj; K Ravi
Journal:  J Clin Diagn Res       Date:  2017-05-01

2.  Influence of geometric design characteristics on primary stability of orthodontic miniscrews.

Authors:  Eman Saad Radwan; Mona A Montasser; Ahmed Maher
Journal:  J Orofac Orthop       Date:  2018-04-10       Impact factor: 1.938

3.  Effect of thread depth and thread pitch on the primary stability of miniscrews receiving a torque load : A finite element analysis.

Authors:  Yushan Ye; Weimin Yi; Song Fan; Luodan Zhao; Yansong Yu; Yingjuan Lu; Qinghe Yao; Wei Wang; Shaohai Chang
Journal:  J Orofac Orthop       Date:  2021-09-28       Impact factor: 1.938

4.  Angled-predrilling depth and mini-implant shape effects on the mechanical properties of self-drilling orthodontic mini-implants during the angled insertion procedure.

Authors:  Yoon-Young Heo; Keun-Chul Cho; Seung-Hak Baek
Journal:  Angle Orthod       Date:  2012-03-03       Impact factor: 2.079

5.  Effect of placement angle on the stability of loaded titanium microscrews in beagle jaws.

Authors:  Zhenrui Xu; Yeke Wu; Lixing Zhao; Yuqiao Zhou; Xing Wei; Na Tang; Xiaoxia Feng; Tian Tang; Zhihe Zhao
Journal:  Angle Orthod       Date:  2012-12-10       Impact factor: 2.079

6.  Comparative evaluation of insertion torque and mechanical stability for self-tapping and self-drilling orthodontic miniscrews - an in vitro study.

Authors:  Michele Tepedino; Francesco Masedu; Claudio Chimenti
Journal:  Head Face Med       Date:  2017-05-30       Impact factor: 2.151

7.  Mechanical Evaluation of the Stability of One or Two Miniscrews under Loading on Synthetic Bone.

Authors:  Andrea Pradal; Ludovica Nucci; Nicola Derton; Maria Elena De Felice; Gianluca Turco; Vincenzo Grassia; Luca Contardo
Journal:  J Funct Biomater       Date:  2020-11-05

8.  Bone quality affects stability of orthodontic miniscrews.

Authors:  Wan-Ping Yu; Ming-Tzu Tsai; Jian-Hong Yu; Heng-Li Huang; Jui-Ting Hsu
Journal:  Sci Rep       Date:  2022-02-18       Impact factor: 4.379

9.  Fixation stability comparison of bone screws based on thread design: buttress thread, triangle thread, and square thread.

Authors:  Xiaoreng Feng; Zhaopei Luo; Yupeng Li; Yiyi Yao; Weichen Qi; Bin Chen; Hongfeng Liang
Journal:  BMC Musculoskelet Disord       Date:  2022-08-30       Impact factor: 2.562

10.  Design characteristics, primary stability and risk of fracture of orthodontic mini-implants: pilot scan electron microscope and mechanical studies.

Authors:  André Walter; Heinz Winsauer; Jordi Marcé-Nogué; Sergi Mojal; Andreu Puigdollers
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-09-01
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.