Literature DB >> 16102403

Histomorphometric and mechanical analyses of the drill-free screw as orthodontic anchorage.

Jong-Wan Kim1, Sug-Joon Ahn, Young-Il Chang.   

Abstract

INTRODUCTION: Drill-free screws were developed to provide convenient orthodontic anchorage. The purpose of this study was to evaluate the effects of the drilling procedure on the stability of the screws under early orthodontic loading.
METHODS: Thirty-two screws were inserted into the jaws of 2 beagles. The screws were divided into 2 groups of 16: the drilling group and the drill-free group. Screws in the drilling group were inserted into the site that had been drilled with a pilot drilling bur, and those in the drill-free group were inserted without drilling. A force of 200 to 300 g was applied using nickel-titanium coil springs 1 week after insertion. Twelve weeks after insertion, mobility was tested with Periotest (Siemens AG, Bensheim, Germany), and the screws with the surrounding bone were prepared for histomorphometric evaluation.
RESULTS: Screws in the drill-free group showed less mobility and more bone-to-metal contact; they had more bone area compared with the drilling group, although bone osseointegration was generally found in both groups.
CONCLUSIONS: With careful technique, drill-free screws can provide stable orthodontic anchorage.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16102403     DOI: 10.1016/j.ajodo.2004.01.030

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  21 in total

1.  Biomechanical properties of orthodontic miniscrews. An in-vitro study.

Authors:  Britta Florvaag; Peter Kneuertz; Frank Lazar; Jürgen Koebke; Joachim E Zöller; Bert Braumann; Robert A Mischkowski
Journal:  J Orofac Orthop       Date:  2010-02-05       Impact factor: 1.938

2.  Does Change in Thread Shape Influence the Pull Out Strength of Mini Implants? An In vitro Study.

Authors:  Aniruddh V Yashwant; S Dilip; R Krishnaraj; K Ravi
Journal:  J Clin Diagn Res       Date:  2017-05-01

3.  A comparitive clinical study between self tapping and drill free screws as a source of rigid orthodontic anchorage.

Authors:  Nishant Gupta; S M Kotrashetti; Vijay Naik
Journal:  J Maxillofac Oral Surg       Date:  2011-05-28

4.  Modified miniplates for temporary skeletal anchorage in orthodontics: placement and removal surgeries.

Authors:  Marie A Cornelis; Nicole R Scheffler; Pierre Mahy; Sergio Siciliano; Hugo J De Clerck; J F Camilla Tulloch
Journal:  J Oral Maxillofac Surg       Date:  2008-07       Impact factor: 1.895

5.  Effect of rotation bump on removal torque of orthodontic mini-implants.

Authors:  Odontuya Gansukh; Jong-Wha Jeong; Jong-Wan Kim; Young-Kyun Kim; Jong-Ho Lee; Tae-Woo Kim
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2013-12-23

6.  Stability of smooth and rough mini-implants: clinical and biomechanical evaluation - an in vivostudy.

Authors:  Giselle Naback Lemes Vilani; Antônio Carlos de Oliveira Ruellas; Carlos Nelson Elias; Cláudia Trindade Mattos
Journal:  Dental Press J Orthod       Date:  2015-10

7.  Effect of surface anodization on stability of orthodontic microimplant.

Authors:  Sanket Karmarker; Wonjae Yu; Hee-Moon Kyung
Journal:  Korean J Orthod       Date:  2012-02-27       Impact factor: 1.372

8.  Effects of predrilling depth and implant shape on the mechanical properties of orthodontic mini-implants during the insertion procedure.

Authors:  Keun-Chul Cho; Seung-Hak Baek
Journal:  Angle Orthod       Date:  2011-11-03       Impact factor: 2.079

9.  Root and bone response to the proximity of a mini-implant under orthodontic loading.

Authors:  Yang-Ku Lee; Jong-Wan Kim; Seung-Hak Baek; Tae-Woo Kim; Young-Il Chang
Journal:  Angle Orthod       Date:  2010-05       Impact factor: 2.079

10.  Is trabecular bone related to primary stability of miniscrews?

Authors:  Mariana Marquezan; Inayá Lima; Ricardo Tadeu Lopes; Eduardo Franzotti Sant'Anna; Margareth Maria Gomes de Souza
Journal:  Angle Orthod       Date:  2013-11-18       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.