Literature DB >> 18213460

Impact of implant design on primary stability of orthodontic mini-implants.

Benedict Wilmes1, Stephanie Ottenstreuer, Yu-Yu Su, Dieter Drescher.   

Abstract

AIM: Skeletal anchorage with mini-implants has greatly broadened the treatment possibilities in orthodontics over the last few years. To reduce implant failure rates, it is advisable to obtain adequate primary stability. The aim of this study was to quantitatively analyze the impact of implant design and dimension on primary stability.
MATERIAL AND METHODS: Forty-two porcine iliac bone segments were prepared and embedded in resin. To evaluate the primary stability, we documented insertion torques of the following mini-implants: Aarhus Screw, AbsoAnchor, LOMAS, Micro-Anchorage-System, ORLUS and Spider Screw. In each bone, five Dual Top Screws were inserted for reference purposes to achieve comparability among the specimens.
RESULTS: We observed wide variation in insertion torques and hence primary stability, depending on mini-implant design and dimension; the great impact that mini-implant diameter has on insertion torques was particularly conspicuous. Conical mini-implants achieved higher primary stabilities than cylindrical designs.
CONCLUSIONS: The diameter and design of the mini-implant thread have a distinctive impact on primary stability. Depending on the region of insertion and local bone quality, the choice of the mini-implant design and size is crucial to establish sufficient primary stability.

Mesh:

Year:  2008        PMID: 18213460     DOI: 10.1007/s00056-008-0727-4

Source DB:  PubMed          Journal:  J Orofac Orthop        ISSN: 1434-5293            Impact factor:   1.938


  30 in total

1.  Morphological and structural characteristics of orthodontic mini-implants.

Authors:  Saeed AlSamak; Elias Bitsanis; Margarita Makou; George Eliades
Journal:  J Orofac Orthop       Date:  2012-01-12       Impact factor: 1.938

2.  Biomechanical properties of orthodontic miniscrews. An in-vitro study.

Authors:  Britta Florvaag; Peter Kneuertz; Frank Lazar; Jürgen Koebke; Joachim E Zöller; Bert Braumann; Robert A Mischkowski
Journal:  J Orofac Orthop       Date:  2010-02-05       Impact factor: 1.938

3.  Assessment of available sites for palatal orthodontic mini-implants through cone-beam computed tomography.

Authors:  Xinwei Lyu; Jiusi Guo; Liangrui Chen; Yi Gao; Lu Liu; Lingling Pu; Wenli Lai; Hu Long
Journal:  Angle Orthod       Date:  2020-07-01       Impact factor: 2.079

4.  Does Change in Thread Shape Influence the Pull Out Strength of Mini Implants? An In vitro Study.

Authors:  Aniruddh V Yashwant; S Dilip; R Krishnaraj; K Ravi
Journal:  J Clin Diagn Res       Date:  2017-05-01

5.  A novel technique for measurement of orthodontic mini-implant stability using the Osstell ISQ device.

Authors:  Yara K Hosein; S Jeffrey Dixon; Amin S Rizkalla; Ali Tassi
Journal:  Angle Orthod       Date:  2018-11-01       Impact factor: 2.079

6.  Direct versus indirect loading of orthodontic miniscrew implants-an FEM analysis.

Authors:  C Holberg; P Winterhalder; N Holberg; I Rudzki-Janson; A Wichelhaus
Journal:  Clin Oral Investig       Date:  2012-10-31       Impact factor: 3.573

7.  Expectations, acceptance and preferences of patients in treatment with orthodontic mini-implants: part II: implant removal.

Authors:  Sandra Lehnen; Fraser McDonald; Christoph Bourauel; Andreas Jäger; Martin Baxmann
Journal:  J Orofac Orthop       Date:  2011-07       Impact factor: 1.938

8.  Insertion torque values and success rates for paramedian insertion of orthodontic mini-implants : A retrospective study.

Authors:  Bruno Di Leonardo; Björn Ludwig; Jörg Alexander Lisson; Luca Contardo; Rossano Mura; Jan Hourfar
Journal:  J Orofac Orthop       Date:  2018-02-20       Impact factor: 1.938

9.  Comparison of skeletal and conventional anchorage methods in conjunction with pre-operative decompensation of a skeletal class III malocclusion.

Authors:  Benedict Wilmes; Gudrun Olthoff; Dieter Drescher
Journal:  J Orofac Orthop       Date:  2009-08-02       Impact factor: 1.938

10.  Multipurpose use of orthodontic mini-implants to achieve different treatment goals.

Authors:  M Nienkemper; B Wilmes; A Pauls; D Drescher
Journal:  J Orofac Orthop       Date:  2012-10-28       Impact factor: 1.938

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.