| Literature DB >> 28654088 |
Hemanth K N Reddy1, Chun Hong Yoon2, Andrew Aquila2, Salah Awel3,4, Kartik Ayyer3, Anton Barty3, Peter Berntsen5, Johan Bielecki1, Sergey Bobkov6, Maximilian Bucher2,7,8, Gabriella A Carini2, Sebastian Carron2, Henry Chapman3,4,9, Benedikt Daurer1, Hasan DeMirci2,10, Tomas Ekeberg1, Petra Fromme11,12, Janos Hajdu1,13, Max Felix Hanke1, Philip Hart2, Brenda G Hogue11,14,15, Ahmad Hosseinizadeh16, Yoonhee Kim17, Richard A Kirian18, Ruslan P Kurta19, Daniel S D Larsson1, N Duane Loh20,21, Filipe R N C Maia1, Adrian P Mancuso19, Kerstin Mühlig1, Anna Munke1, Daewoong Nam17, Carl Nettelblad1,22, Abbas Ourmazd16, Max Rose23, Peter Schwander16, Marvin Seibert1, Jonas A Sellberg1,24, Changyong Song17, John C H Spence18, Martin Svenda1, Gijs Van der Schot1, Ivan A Vartanyants23,25, Garth J Williams26, P Lourdu Xavier3,9,27.
Abstract
Single-particle diffraction from X-ray Free Electron Lasers offers the potential for molecular structure determination without the need for crystallization. In an effort to further develop the technique, we present a dataset of coherent soft X-ray diffraction images of Coliphage PR772 virus, collected at the Atomic Molecular Optics (AMO) beamline with pnCCD detectors in the LAMP instrument at the Linac Coherent Light Source. The diameter of PR772 ranges from 65-70 nm, which is considerably smaller than the previously reported ~600 nm diameter Mimivirus. This reflects continued progress in XFEL-based single-particle imaging towards the single molecular imaging regime. The data set contains significantly more single particle hits than collected in previous experiments, enabling the development of improved statistical analysis, reconstruction algorithms, and quantitative metrics to determine resolution and self-consistency.Entities:
Mesh:
Year: 2017 PMID: 28654088 PMCID: PMC5501160 DOI: 10.1038/sdata.2017.79
Source DB: PubMed Journal: Sci Data ISSN: 2052-4463 Impact factor: 6.444
Figure 1Electron micrograph of purified bacteriophage PR772.
Scale bar represents 100 nm.
Figure 2Sample characterization of PR772.
NTA measurements (b) of bacteriophage PR772 in ammonium acetate buffer (250 mM, pH 7.5). The curve shows the distribution of the different sized particles in the solution. We observed a single large peak at 75 nm with concentration of 108 particles/ml, which is similar to the dilution used for measurement. The diameter peak from the DMA measurement (c) was approximately 60 nm. The actual gas flow during the DMA measurement was lower than the set value, which resulted in a diameter low by about 10%. The gas flow was disregarded since the purpose of the DMA measurement was to assess sample purity and not size. DLS measurements of bacteriophage PR772 in ammonium acetate buffer (250 mM, pH 7.5). Curve in red shows the average of 18 correlation data collected over time for the sample (a). Curves in black and blue show the size of the particles based on mass (d) and intensity (e) distribution respectively. The mean diameter of the particle was 75.99 nm with a polydispersity index (PDI) of 0.012.
Figure 3Diffusion map analysis of all the hits reduced to two dominant dimensions Φ1 and Φ2 as described in the text.
Clustering helps identify the single particle diffraction patterns in the dataset. In addition to single hits (a) and multiple hits (b), the spherical particles (c) classified as ‘water’ may also contain contaminant residue from the sample and buffer. Additionally slightly larger than average background scattering (d) and frames with a defective readout (e) are also shown in the diffusion map.
Figure 4Comparison of single hit selections by principal component analysis (PCA), Chi-sqaured metric and manifold embedding.
Summed diffraction patterns of (a) PCA, (b) Chi-squared metric and (c) manifold embedding. (d) Averaged signal over angle (power spectral density, PSD) as a function of spatial frequency and resolution. Five diffraction maxima are fully captured within the detector edges. The sixth maximum is captured within the detector corners.
Single particle hits data table.
| This table describes the estimated single particle PR772 hits, per raw XTC file, using three different classification methods. Additionally it provided the number of data frames per run, raw XTC file, deposited in the CXIDB. | ||||
|---|---|---|---|---|
| 182 | 97,733 | 15 | 2 | 0 |
| 183 | 169,227 | 3 | 0 | 0 |
| 184 | 136,624 | 1 | 0 | 0 |
| 185 | 77,079 | 7 | 4 | 0 |
| 186 | 453,285 | 2,048 | 1,121 | 4,759 |
| 188 | 322,097 | 1,171 | 599 | 2,885 |
| 190 | 265,585 | 1,498 | 838 | 4,175 |
| 191 | 293,284 | 1,718 | 944 | 4,427 |
| 192 | 224,583 | 1,279 | 656 | 3,209 |
| 193 | 329,049 | 2,525 | 1,370 | 6,781 |
| 194 | 214,891 | 1,661 | 897 | 4,555 |
| 196 | 204,236 | 1,436 | 818 | 3,792 |
| 197 | 188,895 | 1,410 | 743 | 2,967 |
| Total | 2,976,568 | 14,772 | 7,992 | 37,550 |