| Literature DB >> 28652693 |
Kjell G Gundersen1, Rick Potvin2.
Abstract
PURPOSE: To compare two different diffractive trifocal intraocular lens (IOL) designs, evaluating longer-term refractive outcomes, visual acuity (VA) at various distances, low contrast VA and quality of vision. PATIENTS AND METHODS: Patients with binocularly implanted trifocal IOLs of two different designs (FineVision [FV] and Panoptix [PX]) were evaluated 6 months to 2 years after surgery. Best distance-corrected and uncorrected VA were tested at distance (4 m), intermediate (80 and 60 cm) and near (40 cm). A binocular defocus curve was collected with the subject's best distance correction in place. The preferred reading distance was determined along with the VA at that distance. Low contrast VA at distance was also measured. Quality of vision was measured with the National Eye Institute Visual Function Questionnaire near subset and the Quality of Vision questionnaire.Entities:
Keywords: FineVision; Panoptix; contrast sensitivity; defocus curve; multifocal
Year: 2017 PMID: 28652693 PMCID: PMC5472417 DOI: 10.2147/OPTH.S136164
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Subject demographics
| FV | PX | ||
|---|---|---|---|
| n (patients) | 30 | 30 | |
| Age (years) | 58.2±6.6 (45 to 74) | 59.4±8.5 (48 to 73) | 0.54 |
| Female/male | 18/12 | 15/15 | 0.43 |
| RLE/cataract | 21/9 | 13/17 | 0.04 |
| Follow up (days) | 344±85 (175 to 455) | 384±131 (203 to 714) | 0.17 |
| Preoperative refraction (SEQ, D) | −0.96±3.3 (−8.50 to +4.625) | −0.10±2.5 (−7.375 to +4.375) | 0.29 |
| IOL power (D) | 20.51±4.45 (10 to 31) | 21.43±3.51 (13.5 to 27) | 0.22 |
Notes:
Statistically significant, chi-squared test, P<0.05;
Mean ± SD (minimum to maximum).
Abbreviations: FV, FineVision; IOL, intraocular lens; PX, Panoptix; RLE, refractive lens exchange; SEQ, spherical equivalent.
Distribution of postoperative refractive error (n=60 in each group, 120 total)
| Within (D) | All (%) | FV (%) | PX (%) | |
|---|---|---|---|---|
| MRSE (absolute) | 0.25 | 67 | 57 | 77 |
| 0.50 | 26 | 28 | 23 | |
| 0.75 | 4 | 8 | 0 | |
| 1.00 | 3 | 7 | 0 | |
| Refractive cylinder (absolute) | 0.25 | 73 | 70 | 75 |
| 0.50 | 20 | 22 | 18 | |
| 0.75 | 4 | 7 | 2 | |
| 1.00 | 3 | 2 | 5 |
Abbreviations: FV, FineVision; MRSE, mean refraction spherical equivalent; PX, Panoptix.
Figure 1Best distance-corrected binocular defocus curve.
Note: *Statistically significantly different (P<0.05).
Abbreviations: FV, FineVision; PX, Panoptix.
Figure 2Best distance-corrected visual acuity at different distances.
Note: *Statistically significantly different (P<0.05).
Abbreviations: FV, FineVision; PX, Panoptix.
Postoperative results
| FV | PX | ||
|---|---|---|---|
| n (patients/eyes) | 30/60 | 30/60 | |
| Post-op refraction (SEQ, D) | 0.15±0.39 (−0.125 to +1.00) | 0.07±0.26 (−0.875 to +0.875) | 0.22 |
| Post-op cylinder (D) | −0.26±0.25 (−1.00 to 0.00) | −0.23±0.27 (−1.00 to 0.00) | 0.49 |
| Uncorrected VA at 4 m | −0.04±0.07 (−0.18 to 0.14) | −0.05±0.07 (−0.20 to 0.20) | 0.46 |
| Preferred reading distance (cm) | 42.3±5.3 (33 to 56) | 42.7±4.7 (29 to 51) | 0.52 |
| VA at preferred reading distance | 0.11±0.08 (−0.03 to 0.35) | 0.07±0.07 (−0.05 to 0.25) | 0.04 |
| Low contrast VA | 0.38±0.07 (0.24 to 0.52) | 0.35±0.10 (0.08 to 0.54) | 0.10 |
Notes:
Mean ± SD (min to max);
Statistically significant, P<0.05.
Abbreviations: FV, FineVision; Post-op, postoperative; PX, Panoptix; SEQ, spherical equivalent; VA, visual acuity.
Figure 3Quality of Vision results by lens.
Abbreviations: FV, FineVision; Max, maximum; Min, minimum; PX, Panoptix.