| Literature DB >> 27051269 |
Kjell Gunnar Gundersen1, Rick Potvin2.
Abstract
PURPOSE: The aim of this study was to compare a new diffractive trifocal toric lens with an apodized diffractive bifocal toric lens in terms of refractive and visual acuity (VA) outcomes, including low-contrast VA (LCVA), as well as the patient's visual function 3 months after implantation. PATIENTS AND METHODS: This is a randomized prospective study involving bilateral implantation of a trifocal toric or a bifocal toric lens. At 3 months postoperatively, the subject's vision was tested both uncorrected and with his/her best distance correction at: distance (4 m), intermediate (63 cm), and near (40 cm). Binocular defocus curves were measured with no correction and with the subject's best distance correction in place. Quality of vision was measured using the National Eye Institute Visual Function Questionnaire.Entities:
Keywords: FineVision; ReSTOR; astigmatism; contrast sensitivity; defocus curve; multifocal
Year: 2016 PMID: 27051269 PMCID: PMC4803260 DOI: 10.2147/OPTH.S103375
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Demographics by group (n=11 in each group)
| Trifocal | Bifocal | ||
|---|---|---|---|
| Sex (female/male) | 6/5 | 6/5 | 1.00 |
| Age | 62.1±7.5 (51–72) | 70.2±7.8 (51–78) | 0.02 |
| Average preoperative keratometry (D) | 44.8±1.48 (42.73–48.57) | 43.44±1.83 (40.40–46.13) | 0.01 |
| Preoperative corneal astigmatism (D) | 2.11±1.11 (1.04–5.19) | 1.95±0.72 (1.10–3.26) | 0.58 |
| Axial length (mm) | 24.43±1.49 (22.66–27.11) | 24.18±1.52 (22.38–27.12) | 0.57 |
Notes:
Statistically significantly different, P<0.05. Data is presented as mean ± SD (range).
Abbreviation: D, diopters.
VA and refractive data 3 months postoperatively (by eye, n=22 in each group)
| Trifocal | Bifocal | ||
|---|---|---|---|
| Spherical equivalent refraction (D) | 0.22±0.38 (−0.25 to 1.13) | 0.09±0.42 (−0.88 to 0.88) | 0.29 |
| Refractive cylinder (D) | −0.30±0.26 (−0.75 to 0.00) | −0.49±0.45 (−1.50 to 0.00) | 0.09 |
| Uncorrected distance VA (logMAR) | 0.03±−0.10 (−0.20 to 0.32) | 0.08±0.13 (−0.18 to 0.42) | 0.16 |
| Corrected distance VA (logMAR) | −0.01±−0.06 (−0.20 to 0.10) | 0.01±0.07 (−0.18 to 0.16) | 0.44 |
| Low-contrast (10%) VA (logMAR) | 0.32±0.13 (0.18 to 0.56) | 0.35±0.09 (0.12 to 0.56) | 0.39 |
Note:
Statistically significantly different, P<0.05.
Abbreviations: VA, visual acuity; D, diopters.
Figure 1Uncorrected binocular visual acuity by intraocular lens and test distance.
Figure 2Uncorrected (A) and best-corrected (B) binocular defocus curves.
Note: *Statistically significant difference (P<0.05).
Figure 3NEI-VFQ subscale scores by intraocular lens type.
Abbreviation: NEI-VFQ, National Eye Institute Visual Function Questionnaire.