Literature DB >> 27304603

Stability of a Novel Intraocular Lens Design: Comparison of Two Trifocal Lenses.

Francisco Poyales, Nuria Garzón, Jos J Rozema, Concepción Romero, Begoña Ortíz de Zárate.   

Abstract

PURPOSE: To compare visual outcomes, rotational stability, and centration in a randomized controlled trial in patients undergoing cataract surgery who were bilaterally implanted with two different trifocal intraocular lenses (IOLs) with a similar optical zone but different haptic shape.
METHODS: Twenty-one patients (42 eyes) with cataract and less than 1.50 D of corneal astigmatism underwent implantation of one FineVision/MicoF IOL in one eye and one POD FineVision IOL in the contralateral eye (PhysIOL, Liège, Belgium) at IOA Madrid Innova Ocular, Madrid, Spain. IOL allocation was random. Outcome measures, all evaluated 3 months postoperatively, included monocular and binocular uncorrected distance (UDVA), corrected distance (CDVA), distance-corrected intermediate (DCIVA), and near (DCNVA) visual acuity (at 80, 40, and 25 cm) under photopic conditions, refraction, IOL centration, haptic rotation, dysphotopsia, objective quality of vision and aberration quantification, patient satisfaction, and spectacle independence.
RESULTS: Three months postoperatively, mean monocular UDVA, CDVA, DCIVA, and DCNVA (40 cm) under photopic conditions were 0.04 ± 0.07, 0.01 ± 0.04, 0.15 ± 0.11, and 0.16 ± 0.08 logMAR for the eyes implanted with the POD FineVision IOL and 0.03 ± 0.05, 0.01 ± 0.02, 0.17 ± 0.12, and 0.14 ± 0.08 logMAR for those receiving the FineVision/MicroF IOL. Moreover, the POD FineVision IOL showed similar centration (P> .05) and better rotational stability (P < .05) than the FineVision/MicroF IOL. Regarding halos, there was a minimal but statistically significant difference, obtaining better results with FineVision/MicroF. Full spectacle independence was reported by all patients.
CONCLUSIONS: This study revealed similar visual outcomes for both trifocal IOLs under test (POD FineVision and FineVision/MicroF). However, the POD FineVision IOL showed better rotational stability, as afforded by its design. [J Refract Surg. 2016;32(6):394-402.]. Copyright 2016, SLACK Incorporated.

Entities:  

Mesh:

Year:  2016        PMID: 27304603     DOI: 10.3928/1081597X-20160428-04

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  9 in total

1.  Pre-operative simulation of post-operative multifocal vision.

Authors:  Maria Vinas; Sara Aissati; Mercedes Romero; Clara Benedi-Garcia; Nuria Garzon; Francisco Poyales; Carlos Dorronsoro; Susana Marcos
Journal:  Biomed Opt Express       Date:  2019-10-21       Impact factor: 3.732

2.  Comparison of Visual Performance and Patient Satisfaction Outcomes with Two Trifocal IOLs with Similar Optical Design but Different Materials.

Authors:  Francisco Poyales; Ricardo Pérez; Israel López-Brea; Ying Zhou; Laura Rico; Nuria Garzón
Journal:  Clin Ophthalmol       Date:  2020-10-13

3.  Objective and subjective results following implantation of the FineVision trifocal intraocular lens in Mexican patients.

Authors:  Ivo Ferreira-Ríos; Karla Zuñiga-Posselt; Juan Carlos Serna-Ojeda; Eduardo Chávez-Mondragón
Journal:  Int Ophthalmol       Date:  2017-10-12       Impact factor: 2.031

4.  Trifocal intraocular lenses: a comparison of the visual performance and quality of vision provided by two different lens designs.

Authors:  Kjell G Gundersen; Rick Potvin
Journal:  Clin Ophthalmol       Date:  2017-06-08

5.  Evaluation of the optical performance for aspheric intraocular lenses in relation with tilt and decenter errors.

Authors:  Jesús Pérez-Gracia; Alejandra Varea; Jorge Ares; Juan A Vallés; Laura Remón
Journal:  PLoS One       Date:  2020-05-04       Impact factor: 3.240

6.  Exploration of the Visual Function after the Implantation of Continuous Visual Range Human Cocrystal Micromonocular Vision in Both Eyes of the Patient.

Authors:  Fangrong Cai; Xiaoli Wang; Zhihui Deng; Lina Bai
Journal:  J Healthc Eng       Date:  2022-03-07       Impact factor: 2.682

7.  In Vitro Chromatic Performance of Three Presbyopia-Correcting Intraocular Lenses with Different Optical Designs.

Authors:  Diego Montagud-Martínez; Vicente Ferrando; Anabel Martínez-Espert; Salvador Garcia-Delpech; Juan A Monsoriu; Walter D Furlan
Journal:  J Clin Med       Date:  2022-02-24       Impact factor: 4.241

8.  Myopic Shift after Implantation of a Novel Diffractive Trifocal Intraocular Lens in Korean Eyes.

Authors:  Sungsoon Hwang; Dong Hui Lim; Joo Hyun; Myoung Joon Kim; Tae Young Chung
Journal:  Korean J Ophthalmol       Date:  2018-01-24

9.  Comparison of clinical performance between trifocal and bifocal intraocular lenses: A meta-analysis.

Authors:  Zequan Xu; Danmin Cao; Xu Chen; Song Wu; Xin Wang; Qiang Wu
Journal:  PLoS One       Date:  2017-10-26       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.