Literature DB >> 32010498

Model of the light sword intraocular lens: in-vitro comparative studies.

Krzysztof Petelczyc1, Andrzej Kolodziejczyk1, Narcyz Błocki2, Anna Byszewska1,3, Zbigniew Jaroszewicz2,4, Karol Kakarenko1, Katarzyna Kołacz2, Michał Miler1,2, Alejandro Mira-Agudelo5, Walter Torres-Sepúlveda5, Marek Rękas3.   

Abstract

This work presents the first models of light sword intraocular lenses (LS IOLs) with angularly modulated optical power. We performed an experimental, comparative study with multifocal and extended depth of focus intraocular lenses, which are available on the market. The measurements conducted in an original optical bench were utilised for an analysis of point spread functions, elongated foci, modulation transfer functions and the areas defined by them. The LS IOL models perform homogeneous imaging in the whole range of designed defocus. The proposed concept of extended depth of focus seems to be promising for the development of presbyopia-correcting intraocular lenses capable of regaining fully functional vision.
© 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement.

Entities:  

Year:  2019        PMID: 32010498      PMCID: PMC6968750          DOI: 10.1364/BOE.11.000040

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  38 in total

1.  In vitro optical quality comparison between the Mini WELL Ready progressive multifocal and the TECNIS Symfony.

Authors:  Alberto Domínguez-Vicent; Jose Juan Esteve-Taboada; Antonio J Del Águila-Carrasco; Teresa Ferrer-Blasco; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-12-16       Impact factor: 3.117

2.  Comparison of a panfocal and trifocal diffractive intraocular lens after femtosecond laser-assisted lens surgery.

Authors:  Myriam Böhm; Eva Hemkeppler; Michael Herzog; Sabrina Schönbrunn; Nina de'Lorenzo; Kerstin Petermann; Thomas Kohnen
Journal:  J Cataract Refract Surg       Date:  2018-11-02       Impact factor: 3.351

3.  Comparison of bifocal and trifocal diffractive and refractive intraocular lenses using an optical bench.

Authors:  Damien Gatinel; Yvette Houbrechts
Journal:  J Cataract Refract Surg       Date:  2013-05-18       Impact factor: 3.351

4.  Imaging with extended focal depth by means of lenses with radial and angular modulation.

Authors:  G Mikula; Z Jaroszewicz; A Kolodziejczyk; K Petelczyc; M Sypek
Journal:  Opt Express       Date:  2007-07-23       Impact factor: 3.894

5.  Assessment of imaging with extended depth-of-field by means of the light sword lens in terms of visual acuity scale.

Authors:  Karol Kakarenko; Izabela Ducin; Krzysztof Grabowiecki; Zbigniew Jaroszewicz; Andrzej Kolodziejczyk; Alejandro Mira-Agudelo; Krzysztof Petelczyc; Aleksandra Składowska; Maciej Sypek
Journal:  Biomed Opt Express       Date:  2015-04-16       Impact factor: 3.732

6.  [Optical quality of three trifocal intraocular lens models : An optical bench comparison].

Authors:  R Khoramnia; T M Yildirim; T Tandogan; S Liebing; G Łabuz; C Y Choi; G Auffarth
Journal:  Ophthalmologe       Date:  2018-01       Impact factor: 1.059

7.  Comparison of visual quality and subjective outcomes among 3 trifocal intraocular lenses and 1 bifocal intraocular lens.

Authors:  Alfonso Martínez de Carneros-Llorente; Alfonso Martínez de Carneros; Paloma Martínez de Carneros-Llorente; Ignacio Jiménez-Alfaro
Journal:  J Cataract Refract Surg       Date:  2019-03-08       Impact factor: 3.351

8.  Model eyes for evaluation of intraocular lenses.

Authors:  Sverker Norrby; Patricia Piers; Charles Campbell; Marrie van der Mooren
Journal:  Appl Opt       Date:  2007-09-10       Impact factor: 1.980

9.  Optical bench performance of AcrySof(®) IQ ReSTOR(®), AT LISA(®) tri, and FineVision(®) intraocular lenses.

Authors:  Daniel Carson; Warren E Hill; Xin Hong; Mutlu Karakelle
Journal:  Clin Ophthalmol       Date:  2014-10-14

Review 10.  Accommodative intraocular lenses: where are we and where we are going.

Authors:  Jorge L Alió; Jorge L Alió Del Barrio; Alfredo Vega-Estrada
Journal:  Eye Vis (Lond)       Date:  2017-06-26
View more
  2 in total

1.  Method for the generation and visualization of cross-sectional images of three-dimensional point spread functions for rotationally symmetric intraocular lenses.

Authors:  Jan Sievers; Ricardo Elsner; Sebastian Bohn; Melanie Schünemann; Heinrich Stolz; Rudolf F Guthoff; Oliver Stachs; Karsten Sperlich
Journal:  Biomed Opt Express       Date:  2022-02-01       Impact factor: 3.732

Review 2.  Opto-Mechanical Eye Models, a Review on Human Vision Applications and Perspectives for Use in Industry.

Authors:  André Rino Amorim; Boris Bret; José M González-Méijome
Journal:  Sensors (Basel)       Date:  2022-10-10       Impact factor: 3.847

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.