Literature DB >> 28490984

Evaluation of reproducibility of tumor repositioning during multiple breathing cycles for liver stereotactic body radiotherapy treatment.

Ludovic Bedos1, Olivier Riou1, Norbert Aillères1, Antoine Braccini1, Jessica Molinier1, Carmen Llacer Moscardo1, David Azria1, Pascal Fenoglietto1.   

Abstract

AIM: To evaluate the tumor repositioning during gated volumetric modulated arc therapy (VMAT) for liver stereotactic body radiotherapy(SBRT) treatment using implanted fiducial markers and intrafraction kilovoltage (kV) images acquired during dose delivery.
MATERIALS AND METHODS: Since 2012, 47 liver cancer patients with implanted fiducial markers were treated using the gated VMAT technique with a Varian Truebeam STx linear accelerator. The fiducial markers were implanted inside or close to the tumor target before treatment simulation. They were defined at the maximum inhalation and exhalation phases on a 4-dimensionnal computed tomography (4DCT) acquisition. During the treatment, kV images were acquired just before the beam-on at each breathing cycle at maximum exhalation and inhalation phases to verify the fiducial markers positions. For the five first fractions of treatment in the first ten consecutive patients, a total of 2705 intrafraction kV images were retrospectively analyzed to assess the differences between expected and actual positions of the fiducial markers along the cranio-caudal (CC) direction during the exhalation phase.
RESULTS: The mean absolute intrafractional fiducial marker deviation along the CC direction was 1.0 mm at the maximum exhalation phase. In 99%, 95% and 90% cases, the fiducial marker deviations were ≤4.5 mm, 2.8 mm and 2.2 mm, respectively.
CONCLUSION: Intrafraction kV images allowed us to ensure the consistency of tumor repositioning during treatment. In 99% cases, the fiducial marker deviations were ≤4.5 mm corresponding to our 5 mm treatment margin. This margin seems to be well-adapted to the gated VMAT SBRT treatment in liver disease.

Entities:  

Keywords:  Gated VMAT; Intrafraction target motion verification; Respiratory gating

Year:  2016        PMID: 28490984      PMCID: PMC5411957          DOI: 10.1016/j.rpor.2016.07.007

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  24 in total

1.  Commissioning of photon beams of a flattening filter-free linear accelerator and the accuracy of beam modeling using an anisotropic analytical algorithm.

Authors:  Jan Hrbacek; Stephanie Lang; Stephan Klöck
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-12-02       Impact factor: 7.038

2.  Dosimetric properties of photon beams from a flattening filter free clinical accelerator.

Authors:  Oleg N Vassiliev; Uwe Titt; Falk Pönisch; Stephen F Kry; Radhe Mohan; Michael T Gillin
Journal:  Phys Med Biol       Date:  2006-03-21       Impact factor: 3.609

3.  Evaluation of the geometric accuracy of surrogate-based gated VMAT using intrafraction kilovoltage x-ray images.

Authors:  Ruijiang Li; Edward Mok; Bin Han; Albert Koong; Lei Xing
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

4.  Measurement of patient imaging dose for real-time kilovoltage x-ray intrafraction tumour position monitoring in prostate patients.

Authors:  James K Crocker; Jin Aun Ng; Paul J Keall; Jeremy T Booth
Journal:  Phys Med Biol       Date:  2012-04-20       Impact factor: 3.609

5.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76.

Authors:  Paul J Keall; Gig S Mageras; James M Balter; Richard S Emery; Kenneth M Forster; Steve B Jiang; Jeffrey M Kapatoes; Daniel A Low; Martin J Murphy; Brad R Murray; Chester R Ramsey; Marcel B Van Herk; S Sastry Vedam; John W Wong; Ellen Yorke
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

6.  Correlation between internal fiducial tumor motion and external marker motion for liver tumors imaged with 4D-CT.

Authors:  A Sam Beddar; Kristofer Kainz; Tina Marie Briere; Yoshikazu Tsunashima; Tinsu Pan; Karl Prado; Radhe Mohan; Michael Gillin; Sunil Krishnan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-02-01       Impact factor: 7.038

7.  Kilovoltage intrafraction motion monitoring and target dose reconstruction for stereotactic volumetric modulated arc therapy of tumors in the liver.

Authors:  Per Rugaard Poulsen; Esben S Worm; Jørgen B B Petersen; Cai Grau; Walther Fledelius; Morten Høyer
Journal:  Radiother Oncol       Date:  2014-07-02       Impact factor: 6.280

8.  Intrafractional tumor motion: lung and liver.

Authors:  Hiroki Shirato; Yvette Seppenwoolde; Kei Kitamura; Rikiya Onimura; Shinichi Shimizu
Journal:  Semin Radiat Oncol       Date:  2004-01       Impact factor: 5.934

9.  Reduction of respiratory liver tumor motion by abdominal compression in stereotactic body frame, analyzed by tracking fiducial markers implanted in liver.

Authors:  Wouter Wunderink; Alejandra Méndez Romero; Willy de Kruijf; Hans de Boer; Peter Levendag; Ben Heijmen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-07-01       Impact factor: 7.038

10.  Three-dimensional motion of liver tumors using cine-magnetic resonance imaging.

Authors:  Anna Kirilova; Gina Lockwood; Perry Choi; Neelufer Bana; Masoom A Haider; Kristy K Brock; Cynthia Eccles; Laura A Dawson
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-02-06       Impact factor: 7.038

View more
  6 in total

1.  Editorial.

Authors:  Miquel Macià; Carmen Llacer-Moscardo
Journal:  Rep Pract Oncol Radiother       Date:  2016-10-15

2.  Imaged-guided liver stereotactic body radiotherapy using VMAT and real-time adaptive tumor gating. Concerns about technique and preliminary clinical results.

Authors:  Carmen Llacer-Moscardo; Olivier Riou; David Azria; Ludovic Bedos; Norbert Ailleres; Francois Quenet; Philippe Rouanet; Marc Ychou; Pascal Fenoglietto
Journal:  Rep Pract Oncol Radiother       Date:  2016-09-05

3.  Retrospective assessment of a single fiducial marker tracking regimen with robotic stereotactic body radiation therapy for liver tumours.

Authors:  Masao Nakayama; Kazuyuki Uehara; Hideki Nishimura; Shuhei Tamura; Yoshiki Munetomo; Shinji Tsudou; Hiroshi Mayahara; Naritoshi Mukumoto; Moshi Geso; Ryohei Sasaki
Journal:  Rep Pract Oncol Radiother       Date:  2019-06-21

4.  Fiducial marker position affects target volume in stereotactic lung irradiation.

Authors:  Hiroaki Akasaka; Kazufusa Mizonobe; Yuya Oki; Kazuyuki Uehara; Masao Nakayama; Shuhei Tamura; Yoshiki Munetomo; Haruna Kawaguchi; Jun Ishida; Aya Harada; Takeaki Ishihara; Hikaru Kubota; Hiroki Kawaguchi; Ryohei Sasaki; Hiroshi Mayahara
Journal:  J Appl Clin Med Phys       Date:  2022-04-04       Impact factor: 2.243

5.  Intrafractional fiducial marker position variations in stereotactic liver radiotherapy during voluntary deep inspiration breath-hold.

Authors:  Line Bjerregaard Stick; Ivan Richter Vogelius; Signe Risum; Mirjana Josipovic
Journal:  Br J Radiol       Date:  2020-09-11       Impact factor: 3.039

6.  Detectability of fiducials' positions for real-time target tracking system equipping with a standard linac for multiple fiducial markers.

Authors:  Shunsuke Ono; Yoshihiro Ueda; Shingo Ohira; Masaru Isono; Iori Sumida; Shoki Inui; Masahiro Morimoto; Reiko Ashida; Masayoshi Miyazaki; Kazuhiko Ogawa; Teruki Teshima
Journal:  J Appl Clin Med Phys       Date:  2020-10-15       Impact factor: 2.243

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.