Abstract
PURPOSE: Real-time tracking systems of moving respiratory targets such as CyberKnife, Radixact, or Vero4DRT are an advanced robotic radiotherapy device used to deliver stereotactic body radiotherapy (SBRT). The internal target volume (ITV) of lung tumors is assessed through a fiducial marker fusion using four-dimensional computed tomography (CT). It is important to minimize the ITV to protect normal lung tissue from exposure to radiation and the associated side effects post SBRT. However, the ITV may alter if there is a change in the position of the fiducial marker with respect to the tumor. This study investigated the relationship between fiducial marker position and the ITV in order to prevent radiation exposure of normal lung tissue, and correct target coverage.Entities:
Keywords: CyberKnife; fiducial marker; internal target volume; lung cancer; radiotherapy; stereotactic body radiotherapy
Mesh:
Year: 2022 PMID: 35377962 PMCID: PMC9195037 DOI: 10.1002/acm2.13596
Source DB: PubMed Journal: J Appl Clin Med Phys ISSN: 1526-9914 Impact factor: 2.243
Patient characteristics
| Characteristics | All patients ( |
|---|---|
| Sex | |
| Male | 157 (68%) |
| Female | 73 (32%) |
| Age (years) | |
| Median (range) | 76 (41–98) |
| Tumor site | |
| Upper lobe/lower lobe/middle lobe | 100/100/50 |
| V(GTVex) volume (cm3) | |
| Median (range) | 4.03 (0.15–39.76) |
| Mean (SD) | 6.55 (7.51) |
| ITV volume (cm3) | |
| Median (range) | 5.36 (0.31–52.73) |
| Mean (SD) | 8.80 (9.58) |
| PTV margin (mm) | |
| Median (range) | 4 (3–10) |
| Set‐up position | |
| supine/prone set‐up | 232/18 |
Abbreviations: V(GTVex), gross tumor volume in the expiratory phase; ITV, internal target volume; PTV, planning target volume; SD, standard deviation.
FIGURE 1(a) Digital fluoroscopic image showing a microcatheter placed in a smaller pulmonary artery. The coil being pushed out of the catheter is indicated by a white arrow. (b) Schematic drawing of the upper, middle, and lower lobes in the right lung and the upper and lower lobes for the left lung that were used to divide the patients into different subgroups based on tumor location. (c) The distance of the fiducial marker to the gross tumor volume in the expiratory (d ex) and inspiratory (d in) computed tomography (CT) images are shown
FIGURE 2Quantitative comparison results for the distance of the fiducial marker to the gross tumor volume in the (a) expiratory (d ex) and (b) inspiratory (d in) phase computed tomography, (c) gross tumor volume in the expiratory phase (V(GTVex)), and (d) internal target volume (ITV) in the lower, upper, and middle lung lobes
Parameters of d ex, d in, V(GTVex) volume, and ITV
|
| |||||
|---|---|---|---|---|---|
| Parameters | Region | Mean (SD) | Lower vs Upper | Lower vs Middle | Upper vs Middle |
|
| Lower | 9.91 (9.40) | > 0.05 | ||
| Upper | 10.14 (8.82) | ||||
| Middle | 11.99 (12.18) | ||||
|
| Lower | 11.00 (10.32) | > 0.05 | ||
| Upper | 10.86 (9.10) | ||||
| Middle | 12.67 (12.63) | ||||
| V(GTVex) (cc) | Lower | 7.16 (8.33) | > 0.05 | ||
| Upper | 5.83 (6.68) | ||||
| Middle | 6.49 (7.32) | ||||
| ITV (cc) | Lower | 9.65 (10.17) | > 0.05 | ||
| Upper | 7.77 (8.56) | ||||
| Middle | 9.17 (9.76) | ||||
Abbreviations: d ex, expiratory computed tomography; d in, inspiratory computed tomography; V(GTVex), gross tumor volume in the expiratory phase; ITV, internal target volume.
FIGURE 3Quantitative comparison results for (a) the difference (d diff) between the distance of the fiducial marker to the gross tumor volume in the expiratory (d ex) and inspiratory (d in) phase computed tomography, and (b) the ratio of internal target volume (ITV) to gross tumor volume in the expiratory phase (V(GTVex)) in each of the lower, upper, or middle lung lobes according to d ex < 10 mm. Quantitative comparison results for (c) d diff and (d) ITV/V(GTVex) in each of the lower, upper, or middle lung lobes according to d ex ≥ 10 mm
Parameters of d diff and ITV/V(GTVex)
|
| |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Lower | Upper | Middle | |||||||
| Parameters |
| Region | Mean (SD) | Lower vs Upper | Lower vs Middle | Upper vs Middle | < 10 mm vs ≥ 10 mm | < 10 mm vs ≥ 10 mm | < 10 mm vs ≥ 10 mm |
|
| < 10 mm | Lower | 0.43 (0.92) | > 0.05 | < 0.05 | ||||
| Upper | 0.44 (0.90) | ||||||||
| Middle | 0.44 (0.82) | ||||||||
| ≥ 10 mm | Lower | 2.36 (2.09) | < 0.05 | > 0.05 | |||||
| Upper | 1.14 (0.95) | ||||||||
| Middle | 1.47 (1.17) | ||||||||
| ITV/V(GTVex) | < 10 mm | Lower | 1.43 (0.38) | > 0.05 | < 0.05 | ||||
| Upper | 1.34 (0.24) | ||||||||
| Middle | 1.42 (0.21) | ||||||||
| ≥ 10 mm | Lower | 1.69 (0.46) | < 0.05 | > 0.05 | |||||
| Upper | 1.49 (0.39) | ||||||||
| Middle | 1.57 (0.30) | ||||||||
Abbreviations: d ex, expiratory computed tomography; d in, inspiratory computed tomography; d diff, difference between d ex and d in; V(GTVex), gross tumor volume in the expiratory phase; ITV, internal target volume.
FIGURE 4Quantitative comparison results for the difference (d diff) between the distance of the fiducial marker to the gross tumor volume in the expiratory (d ex) and inspiratory (d in) phase computed tomography and the ratio of internal target volume (ITV) to gross tumor volume in the expiratory phase (V(GTVex)) in the lower [(a) and (b), respectively], upper [(c) and (d), respectively], and middle [(e) and (f), respectively] lung lobes grouped according to d ex < 10 mm and ≥10 mm
FIGURE 5The delineations of the gross tumor volume in the expiratory phase (GTVex), the GTV in the inspiratory phase (GTVin) and internal target volume (ITV) equal to the fusion of GTVex and GTVin in (a) lower and (b) upper lung lobes are also shown for the same patient