Literature DB >> 17236980

Correlation between internal fiducial tumor motion and external marker motion for liver tumors imaged with 4D-CT.

A Sam Beddar1, Kristofer Kainz, Tina Marie Briere, Yoshikazu Tsunashima, Tinsu Pan, Karl Prado, Radhe Mohan, Michael Gillin, Sunil Krishnan.   

Abstract

PURPOSE: We investigated the correlation between the motions of an external marker and internal fiducials implanted in the liver for 8 patients undergoing respiratory-based computed tomography (four-dimensional CT [4D-CT]) procedures. METHODS AND MATERIALS: The internal fiducials were gold seeds, 3 mm in length and 1.2 mm in diameter. Four patients each had one implanted fiducial, and the other four had three implanted fiducials. The external marker was a plastic box, which is part of the Real-Time Position Management System (RPM) used to track the patient's respiration. Each patient received a standard helical CT scan followed by a time-correlated CT-image acquisition (4D-CT). The 4D-CT images were reconstructed in 10 separate phases covering the entire respiratory cycle.
RESULTS: The internal fiducial motion is predominant in the superior-inferior direction, with a range of 7.5-17.5 mm. The correlation between external respiration and internal fiducial motion is best during expiration. For 2 patients with their three fiducials separated by a maximum of 3.2 cm, the motions of the fiducials were well correlated, whereas for 2 patients with more widely spaced fiducials, there was less correlation.
CONCLUSIONS: In general, there is a good correlation between internal fiducial motion imaged by 4D-CT and external marker motion. We have demonstrated that gating may be best performed at the end of the respiratory cycle. Special attention should be paid to gating for patients whose fiducials do not move in synchrony, because targeting on the correct respiratory amplitude alone would not guarantee that the entire tumor volume is within the treatment field.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17236980     DOI: 10.1016/j.ijrobp.2006.10.007

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  42 in total

Review 1.  Imaging and image-guided radiation therapy in liver cancer.

Authors:  Kristy K Brock
Journal:  Semin Radiat Oncol       Date:  2011-10       Impact factor: 5.934

2.  A study of porcine liver motion during respiration for improving targeting in image-guided needle placements.

Authors:  G Srimathveeravalli; J Leger; P Ezell; M Maybody; N Gutta; S B Solomon
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-05-27       Impact factor: 2.924

3.  High-quality t2-weighted 4-dimensional magnetic resonance imaging for radiation therapy applications.

Authors:  Dongsu Du; Shelton D Caruthers; Carri Glide-Hurst; Daniel A Low; H Harold Li; Sasa Mutic; Yanle Hu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-03-30       Impact factor: 7.038

4.  Technical note: Correlation of respiratory motion between external patient surface and internal anatomical landmarks.

Authors:  Hadi Fayad; Tinsu Pan; Jean François Clement; Dimitris Visvikis
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

5.  Respiratory motion correction for quantitative PET/CT using all detected events with internal-external motion correlation.

Authors:  Chi Liu; Adam M Alessio; Paul E Kinahan
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

6.  Adaptation of the modified Bouc-Wen model to compensate for hysteresis in respiratory motion for the list-mode binning of cardiac SPECT and PET acquisitions: testing using MRI.

Authors:  Paul K R Dasari; Mohammed Salman Shazeeb; Arda Könik; Clifford Lindsay; Joyeeta M Mukherjee; Karen L Johnson; Michael A King
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

7.  Higher-order singular value decomposition-based lung parcellation for breathing motion management.

Authors:  Samadrita Roy Chowdhury; Joyita Dutta
Journal:  J Med Imaging (Bellingham)       Date:  2019-05-03

8.  Evaluation of reproducibility of tumor repositioning during multiple breathing cycles for liver stereotactic body radiotherapy treatment.

Authors:  Ludovic Bedos; Olivier Riou; Norbert Aillères; Antoine Braccini; Jessica Molinier; Carmen Llacer Moscardo; David Azria; Pascal Fenoglietto
Journal:  Rep Pract Oncol Radiother       Date:  2016-11-12

9.  Mitigating errors in external respiratory surrogate-based models of tumor position.

Authors:  Kathleen T Malinowski; Thomas J McAvoy; Rohini George; Sonja Dieterich; Warren D D'Souza
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-04-01       Impact factor: 7.038

Review 10.  Current status and future prospects of multi-dimensional image-guided particle therapy.

Authors:  Shinichiro Mori; Silvan Zenklusen; Antje-Christin Knopf
Journal:  Radiol Phys Technol       Date:  2013-02-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.