Literature DB >> 28458443

Renal Stone Characterization using High Resolution Imaging Mode on a Photon Counting Detector CT System.

A Ferrero1, R Gutjahr2,3, A Henning2, S Kappler2, A Halaweish4, D Abdurakhimova1, Z Peterson1, J Montoya1, S Leng1, C McCollough1.   

Abstract

In addition to the standard-resolution (SR) acquisition mode, a high-resolution (HR) mode is available on a research photon-counting-detector (PCD) whole-body CT system. In the HR mode each detector consists of a 2x2 array of 0.225 mm × 0.225 mm subpixel elements. This is in contrast to the SR mode that consists of a 4x4 array of the same sub-elements, and results in 0.25 mm isotropic resolution at iso-center for the HR mode. In this study, we quantified ex vivo the capabilities of the HR mode to characterize renal stones in terms of morphology and mineral composition. Forty pure stones - 10 uric acid (UA), 10 cystine (CYS), 10 calcium oxalate monohydrate (COM) and 10 apatite (APA) - and 14 mixed stones were placed in a 20 cm water phantom and scanned in HR mode, at radiation dose matched to that of routine dual-energy stone exams. Data from micro CT provided a reference for the quantification of morphology and mineral composition of the mixed stones. The area under the ROC curve was 1.0 for discriminating UA from CYS, 0.89 for CYS vs COM and 0.84 for COM vs APA. The root mean square error (RMSE) of the percent UA in mixed stones was 11.0% with a medium-sharp kernel and 15.6% with the sharpest kernel. The HR showed qualitatively accurate characterization of stone morphology relative to micro CT.

Entities:  

Keywords:  Computed tomography (CT); high resolution CT; photon-counting detector CT (PCD-CT)

Year:  2017        PMID: 28458443      PMCID: PMC5407385          DOI: 10.1117/12.2255651

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  19 in total

1.  Photon counting spectral CT: improved material decomposition with K-edge-filtered x-rays.

Authors:  Polad M Shikhaliev
Journal:  Phys Med Biol       Date:  2012-03-07       Impact factor: 3.609

Review 2.  Dual-energy CT with single- and dual-source scanners: current applications in evaluating the genitourinary tract.

Authors:  Ravi K Kaza; Joel F Platt; Richard H Cohan; Elaine M Caoili; Mahmoud M Al-Hawary; Ashish Wasnik
Journal:  Radiographics       Date:  2012 Mar-Apr       Impact factor: 5.333

3.  Computed tomography with energy-resolved detection: a feasibility study.

Authors:  Polad M Shikhaliev
Journal:  Phys Med Biol       Date:  2008-02-19       Impact factor: 3.609

4.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography.

Authors:  J P Schlomka; E Roessl; R Dorscheid; S Dill; G Martens; T Istel; C Bäumer; C Herrmann; R Steadman; G Zeitler; A Livne; R Proksa
Journal:  Phys Med Biol       Date:  2008-07-08       Impact factor: 3.609

5.  Photon counting multienergy x-ray imaging: effect of the characteristic x rays on detector performance.

Authors:  Polad M Shikhaliev; Shannon G Fritz; John W Chapman
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

6.  Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging application.

Authors:  Polad M Shikhaliev; Shannon G Fritz
Journal:  Phys Med Biol       Date:  2011-03-02       Impact factor: 3.609

7.  Photon Counting Energy Dispersive Detector Arrays for X-ray Imaging.

Authors:  Jan S Iwanczyk; Einar Nygård; Oded Meirav; Jerry Arenson; William C Barber; Neal E Hartsough; Nail Malakhov; Jan C Wessel
Journal:  IEEE Trans Nucl Sci       Date:  2009       Impact factor: 1.679

8.  Dual energy CT characterization of urinary calculi: initial in vitro and clinical experience.

Authors:  Anno Graser; Thorsten R C Johnson; Markus Bader; Michael Staehler; Nicolas Haseke; Konstantin Nikolaou; Maximilian F Reiser; Christian G Stief; Christoph R Becker
Journal:  Invest Radiol       Date:  2008-02       Impact factor: 6.016

9.  Dual-Energy CT for Quantification of Urinary Stone Composition in Mixed Stones: A Phantom Study.

Authors:  Shuai Leng; Alice Huang; Juan Montoya Cardona; Xinhui Duan; James C Williams; Cynthia H McCollough
Journal:  AJR Am J Roentgenol       Date:  2016-05-25       Impact factor: 3.959

10.  Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array.

Authors:  Zhicong Yu; Shuai Leng; Steven M Jorgensen; Zhoubo Li; Ralf Gutjahr; Baiyu Chen; Ahmed F Halaweish; Steffen Kappler; Lifeng Yu; Erik L Ritman; Cynthia H McCollough
Journal:  Phys Med Biol       Date:  2016-02-02       Impact factor: 3.609

View more
  1 in total

1.  Spectral Photon Counting CT: Imaging Algorithms and Performance Assessment.

Authors:  Adam S Wang; Norbert J Pelc
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-07-07
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.