Literature DB >> 28371774

A Novel Method of Cone Beam CT Projection Binning Based on Image Registration.

Seonyeong Park, Siyong Kim, Byongyong Yi, Geoffrey Hugo, H Michael Gach, Yuichi Motai.   

Abstract

Accurate sorting of beam projections is important in 4D cone beam computed tomography (4D CBCT) to improve the quality of the reconstructed 4D CBCT image by removing motion-induced artifacts. We propose image registration-based projection binning (IRPB), a novel marker-less binning method for 4D CBCT projections, which combines intensity-based feature point detection and trajectory tracking using random sample consensus. IRPB extracts breathing motion and phases by analyzing tissue feature point trajectories. We conducted experiments with two phantom and six patient datasets, including both regular and irregular respirations. In experiments, we compared the performance of the proposed IRPB, Amsterdam Shroud method (AS), Fourier transform-based method (FT), and local intensity feature tracking method (LIFT). The results showed that the average absolute phase shift of IRPB was 3.74 projections and 0.48 projections less than that of FT and LIFT, respectively. AS lost the most breathing cycles in the respiration extraction for the five patient datasets, so we could not compare the average absolute phase shift between IRPB and AS. Based on the peak signal-to-noise ratio (PSNR) of the reconstructed 4D CBCT images, IRPB had 5.08, 1.05, and 2.90 dB larger PSNR than AS, FT, and LIFT, respectively. The average Structure SIMilarity Index (SSIM) of the 4D CBCT image reconstructed by IRPB, AS, and LIFT were 0.87, 0.74, 0.84, and 0.70, respectively. These results demonstrated that IRPB has superior performance to the other standard methods.

Entities:  

Mesh:

Year:  2017        PMID: 28371774      PMCID: PMC5596306          DOI: 10.1109/TMI.2017.2690260

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  24 in total

1.  Image quality assessment: from error visibility to structural similarity.

Authors:  Zhou Wang; Alan Conrad Bovik; Hamid Rahim Sheikh; Eero P Simoncelli
Journal:  IEEE Trans Image Process       Date:  2004-04       Impact factor: 10.856

2.  4D CT image reconstruction with diffeomorphic motion model.

Authors:  Jacob Hinkle; Martin Szegedi; Brian Wang; Bill Salter; Sarang Joshi
Journal:  Med Image Anal       Date:  2012-06-16       Impact factor: 8.545

3.  Respiratory correlated cone beam CT.

Authors:  Jan-Jakob Sonke; Lambert Zijp; Peter Remeijer; Marcel van Herk
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

4.  Measurement of inter and intra fraction organ motion in radiotherapy using cone beam CT projection images.

Authors:  T E Marchant; A M Amer; C J Moore
Journal:  Phys Med Biol       Date:  2008-02-01       Impact factor: 3.609

5.  Comparison of analytic and algebraic methods for motion-compensated cone-beam CT reconstruction of the thorax.

Authors:  Simon Rit; David Sarrut; Laurent Desbat
Journal:  IEEE Trans Med Imaging       Date:  2009-02-10       Impact factor: 10.048

6.  Image quality in thoracic 4D cone-beam CT: a sensitivity analysis of respiratory signal, binning method, reconstruction algorithm, and projection angular spacing.

Authors:  Chun-Chien Shieh; John Kipritidis; Ricky T O'Brien; Zdenka Kuncic; Paul J Keall
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

7.  4D XCAT phantom for multimodality imaging research.

Authors:  W P Segars; G Sturgeon; S Mendonca; Jason Grimes; B M W Tsui
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

8.  The diaphragm as an anatomic surrogate for lung tumor motion.

Authors:  Laura I Cerviño; Alvin K Y Chao; Ajay Sandhu; Steve B Jiang
Journal:  Phys Med Biol       Date:  2009-05-15       Impact factor: 3.609

9.  Extracting respiratory signals from thoracic cone beam CT projections.

Authors:  Hao Yan; Xiaoyu Wang; Wotao Yin; Tinsu Pan; Moiz Ahmad; Xuanqin Mou; Laura Cerviño; Xun Jia; Steve B Jiang
Journal:  Phys Med Biol       Date:  2013-02-11       Impact factor: 3.609

10.  Four-dimensional tissue deformation reconstruction (4D TDR) validation using a real tissue phantom.

Authors:  Martin Szegedi; Jacob Hinkle; Prema Rassiah; Vikren Sarkar; Brian Wang; Sarang Joshi; Bill Salter
Journal:  J Appl Clin Med Phys       Date:  2013-01-07       Impact factor: 2.102

View more
  2 in total

1.  Fluoroscopic 3D Image Generation from Patient-Specific PCA Motion Models Derived from 4D-CBCT Patient Datasets: A Feasibility Study.

Authors:  Salam Dhou; Mohanad Alkhodari; Dan Ionascu; Christopher Williams; John H Lewis
Journal:  J Imaging       Date:  2022-01-18

2.  Low-dose cone-beam CT (LD-CBCT) reconstruction for image-guided radiation therapy (IGRT) by three-dimensional dual-dictionary learning.

Authors:  Ying Song; Weikang Zhang; Hong Zhang; Qiang Wang; Qing Xiao; Zhibing Li; Xing Wei; Jialu Lai; Xuetao Wang; Wan Li; Quan Zhong; Pan Gong; Renming Zhong; Jun Zhao
Journal:  Radiat Oncol       Date:  2020-08-12       Impact factor: 3.481

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.