Hao Yan1, Xiaoyu Wang, Wotao Yin, Tinsu Pan, Moiz Ahmad, Xuanqin Mou, Laura Cerviño, Xun Jia, Steve B Jiang.
Abstract
The patient respiratory signal associated with the cone beam CT (CBCT) projections is important for lung cancer radiotherapy. In contrast to monitoring an external surrogate of respiration, such a signal can be extracted directly from the CBCT projections. In this paper, we propose a novel local principal component analysis (LPCA) method to extract the respiratory signal by distinguishing the respiration motion-induced content change from the gantry rotation-induced content change in the CBCT projections. The LPCA method is evaluated by comparing with three state-of-the-art projection-based methods, namely the Amsterdam Shroud method, the intensity analysis method and the Fourier-transform-based phase analysis method. The clinical CBCT projection data of eight patients, acquired under various clinical scenarios, were used to investigate the performance of each method. We found that the proposed LPCA method has demonstrated the best overall performance for cases tested and thus is a promising technique for extracting a respiratory signal. We also identified the applicability of each existing method.Entities:
Mesh:
Year: 2013 PMID: 23399757 PMCID: PMC6022850 DOI: 10.1088/0031-9155/58/5/1447
Source DB: PubMed Journal: Phys Med Biol ISSN: 0031-9155 Impact factor: 3.609