Literature DB >> 19211348

Comparison of analytic and algebraic methods for motion-compensated cone-beam CT reconstruction of the thorax.

Simon Rit1, David Sarrut, Laurent Desbat.   

Abstract

Respiratory motion is a major concern in cone-beam (CB) computed tomography (CT) of the thorax. It causes artifacts such as blur, streaks, and bands, in particular when using slow-rotating scanners mounted on the gantry of linear accelerators. In this paper, we compare two approaches for motion-compensated CBCT reconstruction of the thorax. The first one is analytic; it is heuristically adapted from the method of Feldkamp, Davis, and Kress (FDK). The second one is algebraic: the system of linear equations is generated using a new algorithm for the projection of deformable volumes and solved using the Simultaneous Algebraic Reconstruction Technique (SART). For both methods, we propose to estimate the motion on patient data using a previously acquired 4-D CT image. The methods were tested on two digital and one mechanical motion-controlled phantoms and on a patient dataset. Our results indicate that the two methods correct most motion artifacts. However, the analytic method does not fully correct streaks and bands even if the motion is perfectly estimated due to the underlying approximation. In contrast, the algebraic method allows us full correction of respiratory-induced artifacts.

Entities:  

Mesh:

Year:  2009        PMID: 19211348     DOI: 10.1109/TMI.2008.2008962

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  16 in total

1.  Limited-angle effect compensation for respiratory binned cardiac SPECT.

Authors:  Wenyuan Qi; Yongyi Yang; Miles N Wernick; P Hendrik Pretorius; Michael A King
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

2.  Reconstruction of four-dimensional computed tomography lung images by applying spatial and temporal anatomical constraints using a Bayesian model.

Authors:  Tiancheng He; Zhong Xue; Bin S Teh; Stephen T Wong
Journal:  J Med Imaging (Bellingham)       Date:  2015-05-13

3.  Resolution enhancement of lung 4D-CT via group-sparsity.

Authors:  Arnav Bhavsar; Guorong Wu; Jun Lian; Dinggang Shen
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

4.  Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. Part I. Numerical model-based optimization.

Authors:  Jang-Hwan Choi; Rebecca Fahrig; Andreas Keil; Thor F Besier; Saikat Pal; Emily J McWalter; Gary S Beaupré; Andreas Maier
Journal:  Med Phys       Date:  2013-09       Impact factor: 4.071

5.  3D fluoroscopic image estimation using patient-specific 4DCBCT-based motion models.

Authors:  S Dhou; M Hurwitz; P Mishra; W Cai; J Rottmann; R Li; C Williams; M Wagar; R Berbeco; D Ionascu; J H Lewis
Journal:  Phys Med Biol       Date:  2015-04-23       Impact factor: 3.609

6.  [High-quality reconstruction of four-dimensional cone beam CT from motion registration prior image].

Authors:  Meiling Chen; Yi Huang; Wufan Chen; Xin Chen; Hua Zhang
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2019-02-28

7.  Estimating the 4D respiratory lung motion by spatiotemporal registration and super-resolution image reconstruction.

Authors:  Guorong Wu; Qian Wang; Jun Lian; Dinggang Shen
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

8.  Harnessing group-sparsity regularization for resolution enhancement of lung 4D-CT.

Authors:  Arnav Bhavsar; Guorong Wu; Dinggang Shen
Journal:  Med Image Comput Comput Assist Interv       Date:  2013

9.  A biomechanical modeling-guided simultaneous motion estimation and image reconstruction technique (SMEIR-Bio) for 4D-CBCT reconstruction.

Authors:  Xiaokun Huang; You Zhang; Jing Wang
Journal:  Phys Med Biol       Date:  2018-02-08       Impact factor: 3.609

10.  A Novel Method of Cone Beam CT Projection Binning Based on Image Registration.

Authors:  Seonyeong Park; Siyong Kim; Byongyong Yi; Geoffrey Hugo; H Michael Gach; Yuichi Motai
Journal:  IEEE Trans Med Imaging       Date:  2017-03-31       Impact factor: 10.048

View more