Transmit/receive radiofrequency coil with individually shielded elements.

Kyle M Gilbert1, Andrew T Curtis, Joseph S Gati, L Martyn Klassen, Lauren E Villemaire, Ravi S Menon.   

Abstract

A novel method for decoupling coil elements of transmit/receive (transceive) arrays is reported. Each element of a coil array is shielded both concentrically and radially to reduce the magnetic flux linkage between neighboring coils; this substantially reduces the mutual inductance between coil elements and allows them to behave independently. A six-channel transceive coil was developed using this decoupling scheme and compared with two conventional decoupling schemes: the partial overlapping of adjacent elements and capacitive decoupling. The radiofrequency coils were designed to image the human head and were tested on a 7-T Varian scanner. The decoupling, transmit uniformity, transmit efficiency, signal-to-noise ratio, and geometry factors were compared between coils. The individually shielded coil achieved higher minimum isolation between elements (2.7-4.0 dB) and lower geometry factors (2-14%) than the overlapped and capacitively decoupled coils, while showing a reduction in transmit efficiency (2.8-5.9 dB) and signal-to-noise ratio (up to 34%). No difference was found in the power absorbed by the sample during a 90° radiofrequency pulse. The inset distance of coil elements within their shields was then reduced, resulting in significant improvement of the transmit efficiency (1.3 dB) and signal-to-noise ratio (28%). The greatest asset of this decoupling method lies in its versatility: transceive coils can be created with elements of arbitrary shape, size, location, and resonant frequency to produce three-dimensional conformal arrays.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20648678     DOI: 10.1002/mrm.22574

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

1.  Dual optimization method of radiofrequency and quasistatic field simulations for reduction of eddy currents generated on 7T radiofrequency coil shielding.

Authors:  Yujuan Zhao; Tiejun Zhao; Shailesh B Raval; Narayanan Krishnamurthy; Hai Zheng; Chad T Harris; William B Handler; Blaine A Chronik; Tamer S Ibrahim
Journal:  Magn Reson Med       Date:  2014-11-03       Impact factor: 4.668

2.  Effects of coplanar shielding for high field MRI.

Authors:  Joseph V Rispoli; Matthew D Wilcox; Samantha By; Steven M Wright; Mary P McDougall
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2016-08

3.  Flexible transceiver array for ultrahigh field human MR imaging.

Authors:  Bing Wu; Xiaoliang Zhang; Chunsheng Wang; Ye Li; Yong Pang; Jonathan Lu; Duan Xu; Sharmila Majumdar; Sarah J Nelson; Daniel B Vigneron
Journal:  Magn Reson Med       Date:  2012-01-13       Impact factor: 4.668

4.  Hybrid monopole/loop coil array for human head MR imaging at 7T.

Authors:  Xinqiang Yan; Long Wei; Rong Xue; Xiaoliang Zhang
Journal:  Appl Magn Reson       Date:  2015-05-01       Impact factor: 0.831

5.  Multichannel Double-Row Transmission Line Array for Human MR Imaging at Ultrahigh Fields.

Authors:  Xinqiang Yan; Jan Ole Pedersen; Long Wei; Xiaoliang Zhang; Rong Xue
Journal:  IEEE Trans Biomed Eng       Date:  2015-02-18       Impact factor: 4.538

6.  Precompensation for mutual coupling between array elements in parallel excitation.

Authors:  Yong Pang; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2011-12

7.  Closely-spaced double-row microstrip RF arrays for parallel MR imaging at ultrahigh fields.

Authors:  Xinqiang Yan; Rong Xue; Xiaoliang Zhang
Journal:  Appl Magn Reson       Date:  2015-06-30       Impact factor: 0.831

8.  Multi-reception strategy with improved SNR for multichannel MR imaging.

Authors:  Bing Wu; Ye Li; Chunsheng Wang; Daniel B Vigneron; Xiaoliang Zhang
Journal:  PLoS One       Date:  2012-08-03       Impact factor: 3.240

9.  Microstrip Transmission Line RF Coil for a PET/MRI Insert.

Authors:  Md Shahadat Hossain Akram; Takayuki Obata; Taiga Yamaya
Journal:  Magn Reson Med Sci       Date:  2019-11-27       Impact factor: 2.471

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.