Literature DB >> 11241709

Specific coil design for SENSE: a six-element cardiac array.

M Weiger1, K P Pruessmann, C Leussler, P Röschmann, P Boesiger.   

Abstract

In sensitivity encoding (SENSE), the effects of inhomogeneous spatial sensitivity of surface coils are utilized for signal localization in addition to common Fourier encoding using magnetic field gradients. Unlike standard Fourier MRI, SENSE images exhibit an inhomogeneous noise distribution, which crucially depends on the geometrical sensitivity relations of the coils used. Thus, for optimum signal-to-noise-ratio (SNR) and noise homogeneity, specialized coil configurations are called for. In this article we study the implications of SENSE imaging for coil layout by means of simulations and imaging experiments in a phantom and in vivo. New, specific design principles are identified. For SENSE imaging, the elements of a coil array should be smaller than for common phased-array imaging. Furthermore, adjacent coil elements should not overlap. Based on the findings of initial investigations, a configuration of six coils was designed and built specifically for cardiac applications. The in vivo evaluation of this array showed a considerable SNR increase in SENSE images, as compared with a conventional array. Magn Reson Med 45:495-504, 2001. Copyright 2001 Wiley-Liss, Inc.

Mesh:

Year:  2001        PMID: 11241709     DOI: 10.1002/1522-2594(200103)45:3<495::aid-mrm1065>3.0.co;2-v

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  26 in total

1.  Moment method analysis of mutual interaction in MRI phased array coils.

Authors:  H Fujita; J W Missal; M A Morich
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

2.  Recent advances in image reconstruction, coil sensitivity calibration, and coil array design for SMASH and generalized parallel MRI.

Authors:  Daniel K Sodickson; Charles A McKenzie; Michael A Ohliger; Ernest N Yeh; Mark D Price
Journal:  MAGMA       Date:  2002-01       Impact factor: 2.310

3.  MRI language dominance assessment in epilepsy patients at 1.0 T: region of interest analysis and comparison with intracarotid amytal testing.

Authors:  K Deblaere; P A Boon; P Vandemaele; A Tieleman; K Vonck; G Vingerhoets; W Backes; L Defreyne; E Achten
Journal:  Neuroradiology       Date:  2004-05-01       Impact factor: 2.804

4.  Highly parallel volumetric imaging with a 32-element RF coil array.

Authors:  Yudong Zhu; Christopher J Hardy; Daniel K Sodickson; Randy O Giaquinto; Charles L Dumoulin; Gontran Kenwood; Thoralf Niendorf; Hubert Lejay; Charles A McKenzie; Michael A Ohliger; Neil M Rofsky
Journal:  Magn Reson Med       Date:  2004-10       Impact factor: 4.668

5.  Versatile coil design and positioning of transverse-field RF surface coils for clinical 1.5-T MRI applications.

Authors:  M Alfonsetti; V Clementi; S Iotti; G Placidi; R Lodi; B Barbiroli; A Sotgiu; M Alecci
Journal:  MAGMA       Date:  2004-12-30       Impact factor: 2.310

6.  32-element receiver-coil array for cardiac imaging.

Authors:  Christopher J Hardy; Harvey E Cline; Randy O Giaquinto; Thoralf Niendorf; Aaron K Grant; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

7.  Fast magnetic resonance imaging of the knee using a parallel acquisition technique (mSENSE): a prospective performance evaluation.

Authors:  Karl-Friedrich Kreitner; Bernd Romaneehsen; Frank Krummenauer; Katja Oberholzer; Lars Peter Müller; Christoph Düber
Journal:  Eur Radiol       Date:  2006-05-30       Impact factor: 5.315

8.  Effects of coplanar shielding for high field MRI.

Authors:  Joseph V Rispoli; Matthew D Wilcox; Samantha By; Steven M Wright; Mary P McDougall
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2016-08

Review 9.  Massively parallel MRI detector arrays.

Authors:  Boris Keil; Lawrence L Wald
Journal:  J Magn Reson       Date:  2013-02-07       Impact factor: 2.229

10.  Performance evaluation of a 32-element head array with respect to the ultimate intrinsic SNR.

Authors:  Riccardo Lattanzi; Aaron K Grant; Jonathan R Polimeni; Michael A Ohliger; Graham C Wiggins; Lawrence L Wald; Daniel K Sodickson
Journal:  NMR Biomed       Date:  2010-02       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.