Literature DB >> 11061203

Changes in interface pressure and stump shape over time: preliminary results from a trans-tibial amputee subject.

J E Sanders1, J M Greve, C Clinton, B J Hafner.   

Abstract

Interface stresses and stump shape were measured during sessions over a two-month interval on a trans-tibial amputee subject. Results from thirteen transducer sites monitored during four sessions showed greater interface pressure changes over time at anterior sites than at lateral or posterior locations. There was a trend of decreased pressure with stump swelling and increased pressure for stump atrophy. During one session in which stump shape was monitored over a 23.1 min interval after ambulation, stump swelling was localised. Swelling tended to increase in the regions of initial enlargement, as opposed to redistributing through different areas over time. Regions of swelling were anterior lateral and posterior proximal, areas of thick underlying soft tissue. Identification of localised areas of swelling and atrophy and understanding of their effects on interface pressures could be used to improve individual socket design.

Entities:  

Mesh:

Year:  2000        PMID: 11061203     DOI: 10.1080/03093640008726539

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  6 in total

1.  Development of Standardized Material Testing Protocols for Prosthetic Liners.

Authors:  John C Cagle; Per G Reinhall; Brian J Hafner; Joan E Sanders
Journal:  J Biomech Eng       Date:  2017-04-01       Impact factor: 2.097

2.  A finite element model to assess transtibial prosthetic sockets with elastomeric liners.

Authors:  John C Cagle; Per G Reinhall; Kate J Allyn; Jake McLean; Paul Hinrichs; Brian J Hafner; Joan E Sanders
Journal:  Med Biol Eng Comput       Date:  2017-12-13       Impact factor: 2.602

3.  Does temporary socket removal affect residual limb fluid volume of trans-tibial amputees?

Authors:  Joan E Sanders; Tyler L Hartley; Reid H Phillips; Marcia A Ciol; Brian J Hafner; Katheryn J Allyn; Dan S Harrison
Journal:  Prosthet Orthot Int       Date:  2015-02-20       Impact factor: 1.895

4.  Comparative study between Dermo, Pelite, and Seal-In X5 liners: effect on patient's satisfaction and perceived problems.

Authors:  Sadeeq Ali; Noor Azuan Abu Osman; Nooranida Arifin; Hossein Gholizadeh; Nasrul Anwar Abd Razak; Wan Abu Bakar Wan Abas
Journal:  ScientificWorldJournal       Date:  2014-08-11

5.  A comparison between the dimensions of positive transtibial residual limb molds prepared by air pressure casting and weight-bearing casting methods.

Authors:  Behnam Hajiaghaei; Ismail Ebrahimi; Mojtaba Kamyab; Hassan Saeedi; Maryam Jalali
Journal:  Med J Islam Repub Iran       Date:  2016-03-08

Review 6.  Review of the socket design and interface pressure measurement for transtibial prosthesis.

Authors:  Gh Pirouzi; N A Abu Osman; A Eshraghi; S Ali; H Gholizadeh; W A B Wan Abas
Journal:  ScientificWorldJournal       Date:  2014-08-13
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.