Material properties of commonly-used interface materials and their static coefficients of friction with skin and socks.

J E Sanders1, J M Greve, S B Mitchell, S G Zachariah.   

Abstract

Compressive stiffness (CS) of different supporting materials used in prosthetics and orthotics and their static coefficients of friction (COF) with skin and socks were characterized. Materials tested included Spenco, Poron, nylon-reinforced silicone, Soft Pelite, Medium Pelite, Firm Plastazote, Regular Plastazote, and Nickelplast. A displacement-controlled testing device was constructed to assess the CS of 11.1 mm diameter material specimens under cyclic loading (1 Hz) to 220 kPa over 10- and 60-min periods. Results demonstrated local CS ranging from 687 kPa (Poron) to 3,990 kPa (Soft Pelite). To fit the cyclic stress-strain (S-S) data within an error of 4.0 percent full-scale output, the minimum order of fit required for Spenco, Poron, and nylon-reinforced silicone was a third-order polynomial; for Soft Pelite, Medium Pelite, Firm Plastazote, and Regular Plastazote, a second-order polynomial; and for Nickelplast, a linear fit. For all materials, the nonrecovered strains were related to loading time using an exponential fit. A biaxial force-controlled load applicator device was used to assess COF at skin-material, sock-material, and skin-sock interfaces for shear forces of 1 to 4 N applied to a 10.2 x 7.8 mm loading pad. COFs ranged from 0.48 (+/- 0.05) to 0.89 (+/- 0.09). COFs at skin-material interfaces were significantly (p < 0.05) higher than those at skin-sock interfaces. There was a trend of a higher COF at sock-material interfaces than at skin-sock interfaces. These data are of potential utility in finite element modeling sensitivity analysis of residual limb-prosthetic socket systems or body-orthosis systems to characterize effects of material features on interface pressure and shear stress distributions.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9651888

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  11 in total

1.  Spatial relationships between shearing stresses and pressure on the plantar skin surface during gait.

Authors:  Samantha Stucke; Daniel McFarland; Larry Goss; Sergey Fonov; Grant R McMillan; Amy Tucker; Necip Berme; Hasan Cenk Guler; Chris Bigelow; Brian L Davis
Journal:  J Biomech       Date:  2011-12-12       Impact factor: 2.712

2.  Plantar foot surface temperatures with use of insoles.

Authors:  Michelle Hall; Donald G Shurr; M Bridget Zimmerman; Charles L Saltzman
Journal:  Iowa Orthop J       Date:  2004

3.  Biomechanical modeling of brace treatment of scoliosis: effects of gravitational loads.

Authors:  Julien Clin; Carl-Éric Aubin; Stefan Parent; Hubert Labelle
Journal:  Med Biol Eng Comput       Date:  2011-02-02       Impact factor: 2.602

4.  Development of Standardized Material Testing Protocols for Prosthetic Liners.

Authors:  John C Cagle; Per G Reinhall; Brian J Hafner; Joan E Sanders
Journal:  J Biomech Eng       Date:  2017-04-01       Impact factor: 2.097

5.  A simulation-based analysis of the effects of variable prosthesis stiffness on interface dynamics between the prosthetic socket and residual limb.

Authors:  Michael A McGeehan; Peter G Adamczyk; Kieran M Nichols; Michael E Hahn
Journal:  J Rehabil Assist Technol Eng       Date:  2022-07-15

6.  Comparison of the biomechanical 3D efficiency of different brace designs for the treatment of scoliosis using a finite element model.

Authors:  Julien Clin; Carl-Eric Aubin; Stefan Parent; Archana Sangole; Hubert Labelle
Journal:  Eur Spine J       Date:  2010-01-22       Impact factor: 3.134

7.  Virtual prototyping of a brace design for the correction of scoliotic deformities.

Authors:  Julien Clin; Carl-Eric Aubin; Hubert Labelle
Journal:  Med Biol Eng Comput       Date:  2007-03-17       Impact factor: 3.079

8.  Validation of a roughness parameters for defining surface roughness of prosthetic polyethylene Pe-Lite liner.

Authors:  Mohd Sayuti Ab Karim; Siti Zuliana Salleh; Nur Afiqah Hamzah; Nasrul Anuar Abd Razak
Journal:  Sci Rep       Date:  2022-02-16       Impact factor: 4.379

9.  Simple model of arch support: Relevance to Charcot Neuroarthropathy.

Authors:  B L Davis; S M Tiell; G R McMillan; L P Goss; J W Crafton
Journal:  Clin Biomech (Bristol, Avon)       Date:  2021-05-29       Impact factor: 2.034

Review 10.  Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahmad Adikan
Journal:  Sensors (Basel)       Date:  2016-07-20       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.