OBJECTIVE: Access to pacemakers remains poor among many patients in low/middle-income countries. Reuse of explanted pacemakers is a possible solution, but is still not widespread because of concerns regarding outcomes, especially infection. Our objective was to study early outcomes with implants using reused devices and compare them with those with implants using new devices. METHODS: We studied all patients who underwent implantation of a new or reused pacemaker, cardiac resynchronisation therapy (CRT) device or implantable cardioverter defibrillator (ICD) in the last 5 years at a single institution. We analysed outcomes related to infection, device malfunction and device-related death within 6 months after initial implantation. RESULTS: During the study period, 887 patients underwent device implant, including 127 CRT devices or ICDs. Of these, 260 devices (29.3%) were reused and the others were new. At 6 months, there were three device-related infections in implants using a new device. There were no infections among patients receiving a reused device. There were no device malfunctions or device-related deaths in either group. CONCLUSIONS: We found no difference in rate of infection or device malfunction among patients getting a reused device as compared with those with a new device. This study reinforces the safety of reusing devices for implant including CRT and ICDs.
OBJECTIVE: Access to pacemakers remains poor among many patients in low/middle-income countries. Reuse of explanted pacemakers is a possible solution, but is still not widespread because of concerns regarding outcomes, especially infection. Our objective was to study early outcomes with implants using reused devices and compare them with those with implants using new devices. METHODS: We studied all patients who underwent implantation of a new or reused pacemaker, cardiac resynchronisation therapy (CRT) device or implantable cardioverter defibrillator (ICD) in the last 5 years at a single institution. We analysed outcomes related to infection, device malfunction and device-related death within 6 months after initial implantation. RESULTS: During the study period, 887 patients underwent device implant, including 127 CRT devices or ICDs. Of these, 260 devices (29.3%) were reused and the others were new. At 6 months, there were three device-related infections in implants using a new device. There were no infections among patients receiving a reused device. There were no device malfunctions or device-related deaths in either group. CONCLUSIONS: We found no difference in rate of infection or device malfunction among patients getting a reused device as compared with those with a new device. This study reinforces the safety of reusing devices for implant including CRT and ICDs.
Authors: M Panja; C N Sarkar; S Kumar; A K Kar; S Mitra; D P Sinha; A Chatterjee; S Roy; N C Sarkar; B Majumder Journal: Indian Heart J Date: 1996 Nov-Dec
Authors: Behzad B Pavri; Yash Lokhandwala; Gaurav V Kulkarni; Mandar Shah; Bharat K Kantharia; Daniel A N Mascarenhas Journal: Ann Intern Med Date: 2012-10-16 Impact factor: 25.391
Authors: Santanu Guha; S Harikrishnan; Saumitra Ray; Rishi Sethi; S Ramakrishnan; Suvro Banerjee; V K Bahl; K C Goswami; Amal Kumar Banerjee; S Shanmugasundaram; P G Kerkar; Sandeep Seth; Rakesh Yadav; Aditya Kapoor; Ajaykumar U Mahajan; P P Mohanan; Sundeep Mishra; P K Deb; C Narasimhan; A K Pancholia; Ajay Sinha; Akshyaya Pradhan; R Alagesan; Ambuj Roy; Amit Vora; Anita Saxena; Arup Dasbiswas; B C Srinivas; B P Chattopadhyay; B P Singh; J Balachandar; K R Balakrishnan; Brian Pinto; C N Manjunath; Charan P Lanjewar; Dharmendra Jain; Dipak Sarma; G Justin Paul; Geevar A Zachariah; H K Chopra; I B Vijayalakshmi; J A Tharakan; J J Dalal; J P S Sawhney; Jayanta Saha; Johann Christopher; K K Talwar; K Sarat Chandra; K Venugopal; Kajal Ganguly; M S Hiremath; Milind Hot; Mrinal Kanti Das; Neil Bardolui; Niteen V Deshpande; O P Yadava; Prashant Bhardwaj; Pravesh Vishwakarma; Rajeeve Kumar Rajput; Rakesh Gupta; S Somasundaram; S N Routray; S S Iyengar; G Sanjay; Satyendra Tewari; Sengottuvelu G; Soumitra Kumar; Soura Mookerjee; Tiny Nair; Trinath Mishra; U C Samal; U Kaul; V K Chopra; V S Narain; Vimal Raj; Yash Lokhandwala Journal: Indian Heart J Date: 2018-06-08
Authors: Sakshi Parasrampuria; Sirish Chandra Srinath Patloori; Reka Karuppusami; David Chase; John Roshan Journal: Indian Pacing Electrophysiol J Date: 2019-12-13