Literature DB >> 28176981

Reuse of pacemakers, defibrillators and cardiac resynchronisation devices.

Raja J Selvaraj1, R Sakthivel1, Santhosh Satheesh1, Ajith Ananthakrishna Pillai1, Pascal Sagnol2, Xavier Jouven2, Bernard Dodinot2, Jayaraman Balachander1.   

Abstract

OBJECTIVE: Access to pacemakers remains poor among many patients in low/middle-income countries. Reuse of explanted pacemakers is a possible solution, but is still not widespread because of concerns regarding outcomes, especially infection. Our objective was to study early outcomes with implants using reused devices and compare them with those with implants using new devices.
METHODS: We studied all patients who underwent implantation of a new or reused pacemaker, cardiac resynchronisation therapy (CRT) device or implantable cardioverter defibrillator (ICD) in the last 5 years at a single institution. We analysed outcomes related to infection, device malfunction and device-related death within 6 months after initial implantation.
RESULTS: During the study period, 887 patients underwent device implant, including 127 CRT devices or ICDs. Of these, 260 devices (29.3%) were reused and the others were new. At 6 months, there were three device-related infections in implants using a new device. There were no infections among patients receiving a reused device. There were no device malfunctions or device-related deaths in either group.
CONCLUSIONS: We found no difference in rate of infection or device malfunction among patients getting a reused device as compared with those with a new device. This study reinforces the safety of reusing devices for implant including CRT and ICDs.

Entities:  

Year:  2017        PMID: 28176981      PMCID: PMC5278343          DOI: 10.1136/heartasia-2016-010828

Source DB:  PubMed          Journal:  Heart Asia        ISSN: 1759-1104


  21 in total

Review 1.  Safety of pacemaker reuse: a meta-analysis with implications for underserved nations.

Authors:  Timir S Baman; Pascal Meier; Joshua Romero; Lindsey Gakenheimer; James N Kirkpatrick; Patricia Sovitch; Hakan Oral; Kim A Eagle
Journal:  Circ Arrhythm Electrophysiol       Date:  2011-04-14

2.  Survival and mortality in 3,701 pacemaker patients: arguments in favor of pacemaker reuse.

Authors:  J Mugica; R Duconge; L Henry
Journal:  Pacing Clin Electrophysiol       Date:  1986-11       Impact factor: 1.976

3.  Long-term complications related to biventricular defibrillator implantation: rate of surgical revisions and impact on survival: insights from the Italian Clinical Service Database.

Authors:  Maurizio Landolina; Maurizio Gasparini; Maurizio Lunati; Saverio Iacopino; Giuseppe Boriani; Carlo Bonanno; Antonello Vado; Alessandro Proclemer; Alessandro Capucci; Chantal Zucchiatti; Sergio Valsecchi; Renato P Ricci; Massimo Santini
Journal:  Circulation       Date:  2011-05-16       Impact factor: 29.690

4.  [Reuse of implanted pacemakers].

Authors:  H Grendahl
Journal:  Tidsskr Nor Laegeforen       Date:  1994-11-30

5.  Reuse of pacemaker.

Authors:  M Panja; C N Sarkar; S Kumar; A K Kar; S Mitra; D P Sinha; A Chatterjee; S Roy; N C Sarkar; B Majumder
Journal:  Indian Heart J       Date:  1996 Nov-Dec

6.  Reuse of permanent cardiac pacemakers.

Authors:  M D Rosengarten; D Portnoy; R C Chiu; A K Paterson
Journal:  Can Med Assoc J       Date:  1985-08-15       Impact factor: 8.262

7.  Reuse of explanted, resterilized implantable cardioverter-defibrillators: a cohort study.

Authors:  Behzad B Pavri; Yash Lokhandwala; Gaurav V Kulkarni; Mandar Shah; Bharat K Kantharia; Daniel A N Mascarenhas
Journal:  Ann Intern Med       Date:  2012-10-16       Impact factor: 25.391

8.  The refurbished pulse generator.

Authors:  H Mond; S Tartaglia; A Cole; G Sloman
Journal:  Pacing Clin Electrophysiol       Date:  1980-05       Impact factor: 1.976

9.  A prospective trial of new versus refurbished cardiac pacemakers: a Canadian experience.

Authors:  M Rosengarten; R Chiu; R Hoffman
Journal:  Can J Cardiol       Date:  1989-04       Impact factor: 5.223

10.  Performance of re-used pacemakers and implantable cardioverter defibrillators compared with new devices at Groote Schuur Hospital in Cape Town, South Africa.

Authors:  Zimasa V Jama; Ashley Chin; Motasim Badri; Bongani M Mayosi
Journal:  Cardiovasc J Afr       Date:  2015 Jul-Aug       Impact factor: 1.167

View more
  4 in total

Review 1.  CSI position statement on management of heart failure in India.

Authors:  Santanu Guha; S Harikrishnan; Saumitra Ray; Rishi Sethi; S Ramakrishnan; Suvro Banerjee; V K Bahl; K C Goswami; Amal Kumar Banerjee; S Shanmugasundaram; P G Kerkar; Sandeep Seth; Rakesh Yadav; Aditya Kapoor; Ajaykumar U Mahajan; P P Mohanan; Sundeep Mishra; P K Deb; C Narasimhan; A K Pancholia; Ajay Sinha; Akshyaya Pradhan; R Alagesan; Ambuj Roy; Amit Vora; Anita Saxena; Arup Dasbiswas; B C Srinivas; B P Chattopadhyay; B P Singh; J Balachandar; K R Balakrishnan; Brian Pinto; C N Manjunath; Charan P Lanjewar; Dharmendra Jain; Dipak Sarma; G Justin Paul; Geevar A Zachariah; H K Chopra; I B Vijayalakshmi; J A Tharakan; J J Dalal; J P S Sawhney; Jayanta Saha; Johann Christopher; K K Talwar; K Sarat Chandra; K Venugopal; Kajal Ganguly; M S Hiremath; Milind Hot; Mrinal Kanti Das; Neil Bardolui; Niteen V Deshpande; O P Yadava; Prashant Bhardwaj; Pravesh Vishwakarma; Rajeeve Kumar Rajput; Rakesh Gupta; S Somasundaram; S N Routray; S S Iyengar; G Sanjay; Satyendra Tewari; Sengottuvelu G; Soumitra Kumar; Soura Mookerjee; Tiny Nair; Trinath Mishra; U C Samal; U Kaul; V K Chopra; V S Narain; Vimal Raj; Yash Lokhandwala
Journal:  Indian Heart J       Date:  2018-06-08

Review 2.  Guidance on reuse of cardio-vascular catheters and devices in India: A consensus document.

Authors:  Aditya Kapoor; Amit Vora; Gita Nataraj; Sundeep Mishra; Prafulla Kerkar; C N Manjunath
Journal:  Indian Heart J       Date:  2017-04-13

3.  Cardiovascular implantable electronic device lead removal in a resource-constrained setting: A single-center experience from India.

Authors:  Sakshi Parasrampuria; Sirish Chandra Srinath Patloori; Reka Karuppusami; David Chase; John Roshan
Journal:  Indian Pacing Electrophysiol J       Date:  2019-12-13

4.  Safety and Efficacy of Submuscular Implantation With Resterilized Cardiac Implantable Electronic Device in Patients With Device Infection: A Retrospective Observational Study in Taiwan.

Authors:  Chia-Meng Yu; Chieh-Ming Yu; Wen-Teng Yao; Ying-Hsiang Lee; Feng-Ching Liao; Chih-Yin Chien; Sheng-Hsiung Chang; Hung-Wei Liao; Yu-Fan Chen; Wen-Chen Huang; Kwang-Yi Tung; Ming-Feng Tsai
Journal:  Open Forum Infect Dis       Date:  2022-04-10       Impact factor: 3.835

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.