Literature DB >> 4016637

Reuse of permanent cardiac pacemakers.

M D Rosengarten, D Portnoy, R C Chiu, A K Paterson.   

Abstract

Cardiac pacemakers are part of a growing group of expensive implantable electronic devices; hospitals in which 100 pacemakers are implanted per year must budget over $300 000 for these devices. This cost represents a considerable burden to health care resources. Since the "life-span" of modern pacemakers often exceeds that of the patients who receive them, the recovery and reuse of these devices seems logical. Pacemakers can be resterilized and tested with current hospital procedures. Reuse should be acceptable under Canadian law, but the manner in which the pacemakers are recovered and the patients selected should follow careful guidelines. Every patient should provide written informed consent before receiving a recovered pacemaker. Properly executed, reuse of pacemakers should provide a high level of health care while maintaining or reducing the cost of these devices.

Entities:  

Mesh:

Year:  1985        PMID: 4016637      PMCID: PMC1345976     

Source DB:  PubMed          Journal:  Can Med Assoc J        ISSN: 0008-4409            Impact factor:   8.262


  22 in total

1.  [Pacemaker reutilization: a study of biological factors and a clinical experience (author's transl)].

Authors:  G A Feruglio; T Pagani
Journal:  G Ital Cardiol       Date:  1978

2.  The re-use of previously implanted pacemakers.

Authors:  T Havia; H Schüller
Journal:  Scand J Thorac Cardiovasc Surg Suppl       Date:  1978

3.  Reuse of the implanted cardiac pacemaker.

Authors:  S Furman
Journal:  Pacing Clin Electrophysiol       Date:  1979-05       Impact factor: 1.976

4.  Pulse generator sterilized and reused.

Authors:  N P Smyth
Journal:  Pacing Clin Electrophysiol       Date:  1979-05       Impact factor: 1.976

5.  Complications of defibrillation with permanent pacemaker in situ.

Authors:  P Aylward; R Blood; A Tonkin
Journal:  Pacing Clin Electrophysiol       Date:  1979-07       Impact factor: 1.976

6.  Protection of implanted pacemakers from excessive electrical energy of D.C. shock.

Authors:  F Y Lau; M Bilitch; H J Wintroub
Journal:  Am J Cardiol       Date:  1969-02       Impact factor: 2.778

7.  The refurbished pulse generator.

Authors:  H Mond; S Tartaglia; A Cole; G Sloman
Journal:  Pacing Clin Electrophysiol       Date:  1980-05       Impact factor: 1.976

8.  Factors influencing survival of patients with permanent cardiac pacemakers.

Authors:  S P Nolan; R S Crampton; L B McGuire; R C McGann; H C Holz; W H Muller
Journal:  Ann Surg       Date:  1977-01       Impact factor: 12.969

9.  Procedure for the evaluation of the virucidal effectiveness of an ethylene oxide gas sterilizer.

Authors:  R W Sidwell; G J Dixon; L Westbrook; E A Dulmadge
Journal:  Appl Microbiol       Date:  1969-06

10.  Neurogenic respiratory failure: a 5-year experience using implantable phrenic nerve stimulators.

Authors:  D D Oakes; C B Wilmot; D Halverson; R D Hamilton
Journal:  Ann Thorac Surg       Date:  1980-08       Impact factor: 4.330

View more
  6 in total

1.  Medical devices labelled for single use: the reuse of permanent cardiac pacemakers.

Authors:  M Rosengarten
Journal:  CMAJ       Date:  1989-06-01       Impact factor: 8.262

2.  Reuse of pacemakers, defibrillators and cardiac resynchronisation devices.

Authors:  Raja J Selvaraj; R Sakthivel; Santhosh Satheesh; Ajith Ananthakrishna Pillai; Pascal Sagnol; Xavier Jouven; Bernard Dodinot; Jayaraman Balachander
Journal:  Heart Asia       Date:  2017-01-23

3.  Societal views of pacemaker reutilization for those with untreated symptomatic bradycardia in underserved nations.

Authors:  Lindsey Gakenheimer; Dave C Lange; Joshua Romero; James N Kirkpatrick; Patricia Sovitch; Hakan Oral; Kim A Eagle; Timir S Baman
Journal:  J Interv Card Electrophysiol       Date:  2011-01-20       Impact factor: 1.900

4.  Reuse of infected cardiac rhythm management devices in the same individual.

Authors:  Duan Jiangbo; Li Xuebin; Zhang Ping; Wang Long; Li Ding; Chu Xianming; Ze Feng; Fang Yong; Yuan Cuizhen; Guo Jihong
Journal:  J Interv Card Electrophysiol       Date:  2012-05-13       Impact factor: 1.900

Review 5.  Inflammation in acquired hydrocephalus: pathogenic mechanisms and therapeutic targets.

Authors:  Jason K Karimy; Benjamin C Reeves; Eyiyemisi Damisah; Phan Q Duy; Prince Antwi; Wyatt David; Kevin Wang; Steven J Schiff; David D Limbrick; Seth L Alper; Benjamin C Warf; Maiken Nedergaard; J Marc Simard; Kristopher T Kahle
Journal:  Nat Rev Neurol       Date:  2020-03-09       Impact factor: 42.937

Review 6.  Guidance on reuse of cardio-vascular catheters and devices in India: A consensus document.

Authors:  Aditya Kapoor; Amit Vora; Gita Nataraj; Sundeep Mishra; Prafulla Kerkar; C N Manjunath
Journal:  Indian Heart J       Date:  2017-04-13
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.