OBJECTIVE: The aim of our study is to present the benefit of using the transvers acetabular ligament for intraoperative determination of the anteversion of acetabular component.
METHODS: Twenty-one total hip arthroplasties were performed. The transverse acetabular ligament was identified and used as a guide to position the acetabular component.
RESULTS: The mean anteversion angle was 16.9. None of the patients studied sustained a postoperative dislocation during this short follow-up period.
CONCLUSION: We conclude from this preliminary study that the transverse acetabular ligament can aid positioning of the acetabular component of a THR. It defines the version of the acetabular component without the need for external instrumentation, and is independent of the position of the patient. Level of Evidence IV; Prospective Study.

Entities:  

Keywords:  Arthroplasty; Hip; Hip dislocation

Year:  2016        PMID: 28149194      PMCID: PMC5266659          DOI: 10.1590/1413-785220162405158405

Source DB:  PubMed          Journal:  Acta Ortop Bras        ISSN: 1413-7852            Impact factor:   0.513


  25 in total

1.  The effect of acetabular cup orientations on limiting hip rotation.

Authors:  F J Kummer; S Shah; S Iyer; P E DiCesare
Journal:  J Arthroplasty       Date:  1999-06       Impact factor: 4.757

Review 2.  Computer simulation: how can it help the surgeon optimize implant position?

Authors:  Philip C Noble; Nobuhiko Sugano; James D Johnston; Matthew T Thompson; Michael A Conditt; Charles A Engh; Kenneth B Mathis
Journal:  Clin Orthop Relat Res       Date:  2003-12       Impact factor: 4.176

3.  Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation?

Authors:  T Kalteis; M Handel; H Bäthis; L Perlick; M Tingart; J Grifka
Journal:  J Bone Joint Surg Br       Date:  2006-02

4.  Variations in acetabular anatomy with reference to total hip replacement.

Authors:  P E Murtha; M A Hafez; B Jaramaz; A M DiGioia
Journal:  J Bone Joint Surg Br       Date:  2008-03

5.  Is transverse acetabular ligament an anatomical landmark to reliably orient the cup in primary total hip arthroplasty?

Authors:  A Viste; J Chouteau; R Testa; L Chèze; M-H Fessy; B Moyen
Journal:  Orthop Traumatol Surg Res       Date:  2011-02-01       Impact factor: 2.256

6.  Accuracy of intraoperative assessment of acetabular prosthesis placement.

Authors:  D M Hassan; G H Johnston; W N Dust; G Watson; A T Dolovich
Journal:  J Arthroplasty       Date:  1998-01       Impact factor: 4.757

7.  The definition and measurement of acetabular orientation.

Authors:  D W Murray
Journal:  J Bone Joint Surg Br       Date:  1993-03

8.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

9.  Polyethylene wear and acetabular component orientation.

Authors:  Shantanu Patil; Arnie Bergula; Peter C Chen; Clifford W Colwell; Darryl D D'Lima
Journal:  J Bone Joint Surg Am       Date:  2003       Impact factor: 5.284

10.  The relationship of the orientation of the transverse acetabular ligament and acetabular labrum to the suggested safe zones of cup positioning in total hip arthroplasty.

Authors:  H A P Archbold; M Slomczykowski; M Crone; K Eckman; B Jaramaz; D E Beverland
Journal:  Hip Int       Date:  2008 Jan-Mar       Impact factor: 1.756

View more
  4 in total

1.  Accuracy of plain antero-posterior radiographic-based methods for measurement of acetabular cup version.

Authors:  Mohammad Ali Alzohiry; Mohammad Kamal Abdelnasser; Mohamed Moustafa; Mohamed Mahran; Hatem Bakr; Yaser Khalifa; Ahmed Abelaal; Haisam Atta; Galal Zaki Said
Journal:  Int Orthop       Date:  2018-06-04       Impact factor: 3.075

2.  "Channel Lines": A Simple Surgical Technique to Aid in Achieving Patient-specific Ante-version During Implantation of Uncemented Acetabular Cups.

Authors:  Roshan Raghavan; Christos Plakogiannis
Journal:  Tech Orthop       Date:  2017-12-25

3.  The influence of sagittal pelvic malrotation on transverse acetabular ligament guided cup orientation: a retrospective cohort study.

Authors:  Tingxian Ling; Zichuan Ding; Mingcheng Yuan; Kai Zhou; Zongke Zhou
Journal:  BMC Musculoskelet Disord       Date:  2021-05-28       Impact factor: 2.362

4.  Mid-term and long-term results of restoring rotation center in revision hip arthroplasty.

Authors:  Heng Zhang; Jiansheng Zhou; Yang Liu; Jianzhong Guan; Hai Ding; Zhiyan Wang; Qirong Dong
Journal:  J Orthop Surg Res       Date:  2020-04-16       Impact factor: 2.359

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.