Literature DB >> 28093635

Different intraoperative kinematics, stability, and range of motion between cruciate-substituting ultracongruent and posterior-stabilized total knee arthroplasty.

Hagen Fritzsche1, Franziska Beyer1, Anne Postler1, Jörg Lützner2.   

Abstract

PURPOSE: The aim of this study was the comparison of intraoperative kinematics, stability, and range of motion (ROM) between the native osteoarthritic knee and cruciate-substituting fixed-bearing total knee arthroplasty (TKA) using both an ultracongruent (UC) and a posterior-stabilized (PS) insert design in the same patient. We hypothesized less knee flexion and less antero-posterior stability in the UC TKA.
METHODS: Intraoperative measurements of kinematics, stability, and ROM were performed in 40 patients before soft-tissue release and bone cuts, and after implantation of the final femoral and tibial implants with both a UC insert and a PS insert. All measurements were performed using a navigation system.
RESULTS: Kinematics changed significantly from a constant posterior femoral rollback before surgery to a paradoxical anterior translation during initial knee flexion with both inserts, but less pronounced with the PS insert (p < 0.001). There was significantly more posterior femoral rollback with the PS insert compared to the UC insert (p < 0.01). Stability measurements demonstrated no differences at full extension and 30° of knee flexion but significantly increased antero-posterior translation in 60° and 90° of knee flexion with the UC insert compared to the PS insert (p < 0.001). ROM measurements demonstrated improvement of knee flexion from 118° at the beginning of the surgery to 123° with the UC insert and 128° with the PS insert (p < 0.001).
CONCLUSION: The use of a UC insert intraoperatively resulted in less antero-posterior stability and slightly less knee flexion compared to a PS insert. Surgeons should be aware of these differences when deciding for one of these options to substitute the posterior cruciate ligament (PCL). The impact of these findings on clinical outcome needs further investigation. LEVEL OF EVIDENCE: II.

Entities:  

Keywords:  Deep dished insert; Range of motion; Results; Stability; TKA; Ultracongruent insert

Mesh:

Year:  2017        PMID: 28093635     DOI: 10.1007/s00167-017-4427-8

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  22 in total

1.  Posterior stabilization in total knee arthroplasty with use of an ultracongruent polyethylene insert.

Authors:  A A Hofmann; T K Tkach; C J Evanich; M P Camargo
Journal:  J Arthroplasty       Date:  2000-08       Impact factor: 4.757

2.  Less femorotibial rotation and AP translation in deep-dished total knee arthroplasty. An intraoperative kinematic study using navigation.

Authors:  Philippe Massin; Patrick Boyer; Marc Sabourin
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-05       Impact factor: 4.342

3.  Comparison of total knee arthroplasty with highly congruent anterior-stabilized bearings versus a cruciate-retaining design.

Authors:  Christopher L Peters; Patrick Mulkey; Jill Erickson; Michael B Anderson; Christopher E Pelt
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

4.  In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties.

Authors:  S A Banks; G D Markovich; W A Hodge
Journal:  J Arthroplasty       Date:  1997-04       Impact factor: 4.757

5.  How much of the PCL is really preserved during the tibial cut?

Authors:  Georg Matziolis; Saskia Mehlhorn; Nicole Schattat; Gerd Diederichs; Robert Hube; Carsten Perka; Doerte Matziolis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-11       Impact factor: 4.342

6.  Tibio-femoral movement in the living knee. A study of weight bearing and non-weight bearing knee kinematics using 'interventional' MRI.

Authors:  P Johal; A Williams; P Wragg; D Hunt; W Gedroyc
Journal:  J Biomech       Date:  2005-02       Impact factor: 2.712

7.  Deep-dish congruent tibial component use in total knee arthroplasty: a randomized prospective study.

Authors:  R S Laskin; Y Maruyama; M Villaneuva; R Bourne
Journal:  Clin Orthop Relat Res       Date:  2000-11       Impact factor: 4.176

8.  Intraoperative flexion against gravity as an indication of ultimate range of motion in individual cases after total knee arthroplasty.

Authors:  D C Lee; D H Kim; R D Scott; K Suthers
Journal:  J Arthroplasty       Date:  1998-08       Impact factor: 4.757

9.  No difference in range of motion between ultracongruent and posterior stabilized design in total knee arthroplasty: a randomized controlled trial.

Authors:  Jörg Lützner; Franziska Beyer; Julian Dexel; Hagen Fritzsche; Cornelia Lützner; Stephan Kirschner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-09-22       Impact factor: 4.342

10.  The patellar clunk syndrome. A complication of posterior stabilized total knee arthroplasty.

Authors:  W J Hozack; R H Rothman; R E Booth; R A Balderston
Journal:  Clin Orthop Relat Res       Date:  1989-04       Impact factor: 4.176

View more
  9 in total

1.  The effect of different insert design congruencies on the kinematics of a mobile bearing TKA: A cadaveric study.

Authors:  Gianluca Castellarin; Edoardo Bori; Alessandra Menon; Bernardo Innocenti
Journal:  J Orthop       Date:  2022-08-10

2.  Equivalent outcomes of ultra-congruent and standard cruciate-retaining inserts in total knee arthroplasty.

Authors:  Karthik Vishwanathan; Srinivas B S Kambhampati; Raju Vaishya
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-01-11       Impact factor: 4.114

Review 3.  Comparison of Functional Outcomes, Femoral Rollback and Sagittal Stability of Anterior-Stabilized Versus Posterior-Stabilized Total Knee Arthroplasty: A Systematic Review and Meta-analysis of Randomized Controlled Trials.

Authors:  Balgovind S Raja; Aditya K S Gowda; Sajid Ansari; Arghya Kundu Choudhury; Roop Bhushan Kalia
Journal:  Indian J Orthop       Date:  2021-08-23       Impact factor: 1.033

4.  Posterior-stabilized inserts are preferable to cruciate-substituting ultracongruent inserts due to more favourable kinematics and stability.

Authors:  Ji-Hoon Bae; Jung-Ro Yoon; Ju-Hyoung Sung; Young-Soo Shin
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-02-19       Impact factor: 4.342

5.  Does the medial pivot knee improve the clinical and radiographic outcome of total knee arthroplasty? A single centre study on two hundred and ninety seven patients.

Authors:  Giorgio Cacciola; Ivan De Martino; Federico De Meo
Journal:  Int Orthop       Date:  2019-12-21       Impact factor: 3.075

Review 6.  Mid-term survivorship and clinical outcomes of the medial stabilized systems in primary total knee arthroplasty: A systematic review.

Authors:  Giorgio Cacciola; Fabio Mancino; Federico De Meo; Vincenzo Di Matteo; Peter K Sculco; Pietro Cavaliere; Giulio Maccauro; Ivan De Martino
Journal:  J Orthop       Date:  2021-02-22

7.  [Effectiveness comparison of partial versus intact posterior cruciate ligament-retaining in total knee arthroplasty with cruciate-retaining prosthesis].

Authors:  Bo Zhang; Yuan Lin; Shixiang Ren; Tong Chen; Xiaoxiong Zhao; Yang Yu
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-01-15

8.  Similar outcomes including maximum knee flexion between mobile bearing condylar-stabilised and fixed bearing posterior-stabilised prosthesis: a case control study.

Authors:  Jobe Shatrov; Elliot Sappey-Marinier; Moussa Kafelov; Stanislas Gunst; Cécile Batailler; Elvire Servien; Sébastien Lustig
Journal:  J Exp Orthop       Date:  2022-02-15

9.  Initiating range of motion exercises within 24 hours following total knee arthroplasty affects the reduction of postoperative pain: A randomized controlled trial.

Authors:  Kentaro Iwakiri; Yoichi Ohta; Yuuki Shibata; Yukihide Minoda; Akio Kobayashi; Hiroaki Nakamura
Journal:  Asia Pac J Sports Med Arthrosc Rehabil Technol       Date:  2020-04-28
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.