Literature DB >> 10959995

Posterior stabilization in total knee arthroplasty with use of an ultracongruent polyethylene insert.

A A Hofmann1, T K Tkach, C J Evanich, M P Camargo.   

Abstract

Fifty-three primary and 47 revision posterior cruciate ligament (PCL)-substituting total knee arthroplasties (TKAs) using a highly conforming (ultracongruent) polyethylene insert were retrospectively reviewed over a 48- to 106-month (mean, 60+/-11 months) follow-up period. These 100 knees were age and sex matched with another 100 TKAs performed using a PCL-sparing design. The ultracongruent design has an anterior buildup of 12.5 mm and a more conforming articular surface to match better the radius of the femoral component. In primary and revision TKAs, the average Hospital for Special Surgery knee score (P = .3) and range of motion (P = .43) were similar between the PCL-sparing and ultracongruent groups. In primary and revision TKAs, there were no revisions resulting from instability for patients receiving an ultracongruent insert versus 5 knees in the PCL-sparing control group secondary to subsequent postoperative anteroposterior instability and PCL insufficiency.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10959995     DOI: 10.1054/arth.2000.6633

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  21 in total

1.  Comparison of total knee arthroplasty with highly congruent anterior-stabilized bearings versus a cruciate-retaining design.

Authors:  Christopher L Peters; Patrick Mulkey; Jill Erickson; Michael B Anderson; Christopher E Pelt
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

2.  Highly crosslinked polyethylene is safe for use in total knee arthroplasty.

Authors:  Jeffrey T Hodrick; Erik P Severson; Deborah S McAlister; Brian Dahl; Aaron A Hofmann
Journal:  Clin Orthop Relat Res       Date:  2008-09-10       Impact factor: 4.176

3.  Three different cruciate-sacrificing TKA designs: minor intraoperative kinematic differences and negligible clinical differences.

Authors:  Simone Bignozzi; Stefano Zaffagnini; Ibrahim Akkawi; Tedi Marko; Danilo Bruni; Maria Pia Neri; Francesca Colle; Maurilio Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-07-29       Impact factor: 4.342

4.  Different intraoperative kinematics with comparable clinical outcomes of ultracongruent and posterior stabilized mobile-bearing total knee arthroplasty.

Authors:  Tae Woo Kim; Sang Min Lee; Sang Cheol Seong; Sahnghoon Lee; Jak Jang; Myung Chul Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-01-08       Impact factor: 4.342

5.  Deep-dished highly congruent tibial insert in CR-TKA does not prevent patellar tendon angle increase and patellar anterior translation.

Authors:  Ibrahim Akkawi; Francesca Colle; Danilo Bruni; Giovanni Francesco Raspugli; Simone Bignozzi; Stefano Zaffagnini; Francesco Iacono; Maurilio Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-02-12       Impact factor: 4.342

6.  Similar stability and range of motion between cruciate-retaining and cruciate-substituting ultracongruent insert total knee arthroplasty.

Authors:  Jörg Lützner; F-P Firmbach; C Lützner; J Dexel; S Kirschner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-02-12       Impact factor: 4.342

7.  Comparison of ultra-congruent mobile- and fixed-bearing navigation-assisted total knee arthroplasty with minimum 5-year follow-up.

Authors:  Seong Hwan Kim; Jung-Won Lim; Young-Bong Ko; Min-Gu Song; Han-Jun Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-05-04       Impact factor: 4.342

8.  Different intraoperative kinematics, stability, and range of motion between cruciate-substituting ultracongruent and posterior-stabilized total knee arthroplasty.

Authors:  Hagen Fritzsche; Franziska Beyer; Anne Postler; Jörg Lützner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-01-16       Impact factor: 4.342

9.  Unsatisfactory clinical outcomes of second-generation mobile bearing floating platform total knee arthroplasty: comparing outcomes with fixed bearing after five years minimum.

Authors:  Jung-Ro Yoon; Jae-Hyuk Yang
Journal:  Int Orthop       Date:  2018-03-20       Impact factor: 3.075

10.  Total knee arthroplasty using ultra-congruent inserts can provide similar stability and function compared with cruciate-retaining total knee arthroplasty.

Authors:  Eun-Kyoo Song; Hong-An Lim; Sang-Don Joo; Sung-Kyu Kim; Keun-Bae Lee; Jong-Keun Seon
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-04-24       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.