The effect of beam purity and scanner complexity on proton CT accuracy.

P Piersimoni1, J Ramos-Méndez1, T Geoghegan1, V A Bashkirov2, R W Schulte2, B A Faddegon1.   

Abstract

PURPOSE: To determine the dependence of the accuracy in reconstruction of relative stopping power (RSP) with proton computerized tomography (pCT) scans on the purity of the proton beam and the technological complexity of the pCT scanner using standard phantoms and a digital representation of a pediatric patient.
METHODS: The Monte Carlo method was applied to simulate the pCT scanner, using both a pure proton beam (uniform 200 MeV mono-energetic, parallel beam) and the Northwestern Medicine Chicago Proton Center (NMCPC) clinical beam in uniform scanning mode. The accuracy of the simulation was validated with measurements performed at NMCPC including reconstructed RSP images obtained with a preclinical prototype pCT scanner. The pCT scanner energy detector was then simulated in three configurations of increasing complexity: an ideal totally absorbing detector, a single stage detector and a multi-stage detector. A set of 15 cm diameter water cylinders containing either water alone or inserts of different material, size, and position were simulated at 90 projection angles (4° steps) for the pure and clinical proton beams and the three pCT configurations. A pCT image of the head of a detailed digital pediatric phantom was also reconstructed from the simulated pCT scan with the prototype detector.
RESULTS: The RSP error increased for all configurations for insert sizes under 7.5 mm in radius, with a sharp increase below 5 mm in radius, attributed to a limit in spatial resolution. The highest accuracy achievable using the current pCT calibration step phantom and reconstruction algorithm, calculated for the ideal case of a pure beam with totally absorbing energy detector, was 1.3% error in RSP for inserts of 5 mm radius or more, 0.7 mm in range for the 2.5 mm radius inserts, or better. When the highest complexity of the scanner geometry was introduced, some artifacts arose in the reconstructed images, particularly in the center of the phantom. Replacing the step phantom used for calibration with a wedge phantom led to RSP accuracy close to the ideal case, with no significant dependence of RSP error on insert location or material. The accuracy with the multi-stage detector and NMCPC beam for the cylindrical phantoms was 2.2% in RSP error for inserts of 5 mm radius or more, 0.7 mm in range for the 2.5 mm radius inserts, or better. The pCT scan of the pediatric phantom resulted in mean RSP values within 1.3% of the reference RSP, with a range error under 1 mm, except in exceptional situations of parallel incidence on a boundary between low and high density.
CONCLUSIONS: The pCT imaging technique proved to be a precise and accurate imaging tool, rivaling the current x-rays based techniques, with the advantage of being directly sensitive to proton stopping power rather than photon interaction coefficients. Measured and simulated pCT images were obtained from a wobbled proton beam for the first time. Since the in-silico results are expected to accurately represent the prototype pCT, upcoming measurements using the wedge phantom for calibration are expected to show similar accuracy in the reconstructed RSP.
© 2016 American Association of Physicists in Medicine.

Entities:  

Keywords:  Geant4; MC simulation; TOPAS; protonCT; quality assurance

Mesh:

Substances:

Year:  2017        PMID: 28066887      PMCID: PMC5362942          DOI: 10.1002/mp.12013

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  30 in total

1.  The most likely path of an energetic charged particle through a uniform medium.

Authors:  D C Williams
Journal:  Phys Med Biol       Date:  2004-07-07       Impact factor: 3.609

2.  An evaluation of spatial resolution of a prototype proton CT scanner.

Authors:  Tia E Plautz; V Bashkirov; V Giacometti; R F Hurley; R P Johnson; P Piersimoni; H F-W Sadrozinski; R W Schulte; A Zatserklyaniy
Journal:  Med Phys       Date:  2016-12       Impact factor: 4.071

3.  TOPAS: an innovative proton Monte Carlo platform for research and clinical applications.

Authors:  J Perl; J Shin; J Schumann; B Faddegon; H Paganetti
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

4.  Proton radiography and fluoroscopy of lung tumors: a Monte Carlo study using patient-specific 4DCT phantoms.

Authors:  Bin Han; X George Xu; George T Y Chen
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

5.  Water-equivalent path length calibration of a prototype proton CT scanner.

Authors:  R F Hurley; R W Schulte; V A Bashkirov; A J Wroe; A Ghebremedhin; H F-W Sadrozinski; V Rykalin; G Coutrakon; P Koss; B Patyal
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

6.  Experimental validation of the TOPAS Monte Carlo system for passive scattering proton therapy.

Authors:  M Testa; J Schümann; H-M Lu; J Shin; B Faddegon; J Perl; H Paganetti
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

7.  The UF family of reference hybrid phantoms for computational radiation dosimetry.

Authors:  Choonsik Lee; Daniel Lodwick; Jorge Hurtado; Deanna Pafundi; Jonathan L Williams; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2009-12-17       Impact factor: 3.609

8.  A Fast Experimental Scanner for Proton CT: Technical Performance and First Experience with Phantom Scans.

Authors:  Robert P Johnson; Vladimir Bashkirov; Langley DeWitt; Valentina Giacometti; Robert F Hurley; Pierluigi Piersimoni; Tia E Plautz; Hartmut F-W Sadrozinski; Keith Schubert; Reinhard Schulte; Blake Schultze; Andriy Zatserklyaniy
Journal:  IEEE Trans Nucl Sci       Date:  2015-12-10       Impact factor: 1.679

9.  The composition of body tissues.

Authors:  H Q Woodard; D R White
Journal:  Br J Radiol       Date:  1986-12       Impact factor: 3.039

10.  Software platform for simulation of a prototype proton CT scanner.

Authors:  Valentina Giacometti; Vladimir A Bashkirov; Pierluigi Piersimoni; Susanna Guatelli; Tia E Plautz; Hartmut F-W Sadrozinski; Robert P Johnson; Andriy Zatserklyaniy; Thomas Tessonnier; Katia Parodi; Anatoly B Rosenfeld; Reinhard W Schulte
Journal:  Med Phys       Date:  2017-03       Impact factor: 4.506

View more
  8 in total

1.  A comparison of proton stopping power measured with proton CT and x-ray CT in fresh postmortem porcine structures.

Authors:  Don F DeJongh; Ethan A DeJongh; Victor Rykalin; Greg DeFillippo; Mark Pankuch; Andrew W Best; George Coutrakon; Kirk L Duffin; Nicholas T Karonis; Caesar E Ordoñez; Christina Sarosiek; Reinhard W Schulte; John R Winans; Alec M Block; Courtney L Hentz; James S Welsh
Journal:  Med Phys       Date:  2021-11-18       Impact factor: 4.071

2.  The accuracy of helium ion CT based particle therapy range prediction: an experimental study comparing different particle and x-ray CT modalities.

Authors:  L Volz; C-A Collins-Fekete; E Bär; S Brons; C Graeff; R P Johnson; A Runz; C Sarosiek; R W Schulte; J Seco
Journal:  Phys Med Biol       Date:  2021-11-29       Impact factor: 3.609

3.  Stopping power accuracy and achievable spatial resolution of helium ion imaging using a prototype particle CT detector system.

Authors:  Lennart Volz; Charles-Antoine Collins-Fekete; Pierluigi Piersimoni; Robert P Johnson; Vladimir Bashkirov; Reinhard Schulte; Joao Seco
Journal:  Curr Dir Biomed Eng       Date:  2017-09-07

4.  Helium CT: Monte Carlo simulation results for an ideal source and detector with comparison to proton CT.

Authors:  Pierluigi Piersimoni; Bruce A Faddegon; José Ramos Méndez; Reinhard W Schulte; Lennart Volz; Joao Seco
Journal:  Med Phys       Date:  2018-05-20       Impact factor: 4.071

5.  The TOPAS tool for particle simulation, a Monte Carlo simulation tool for physics, biology and clinical research.

Authors:  Bruce Faddegon; José Ramos-Méndez; Jan Schuemann; Aimee McNamara; Jungwook Shin; Joseph Perl; Harald Paganetti
Journal:  Phys Med       Date:  2020-04-03       Impact factor: 2.685

6.  The impact of secondary fragments on the image quality of helium ion imaging.

Authors:  Lennart Volz; Pierluigi Piersimoni; Vladimir A Bashkirov; Stephan Brons; Charles-Antoine Collins-Fekete; Robert P Johnson; Reinhard W Schulte; Joao Seco
Journal:  Phys Med Biol       Date:  2018-10-02       Impact factor: 3.609

7.  Software platform for simulation of a prototype proton CT scanner.

Authors:  Valentina Giacometti; Vladimir A Bashkirov; Pierluigi Piersimoni; Susanna Guatelli; Tia E Plautz; Hartmut F-W Sadrozinski; Robert P Johnson; Andriy Zatserklyaniy; Thomas Tessonnier; Katia Parodi; Anatoly B Rosenfeld; Reinhard W Schulte
Journal:  Med Phys       Date:  2017-03       Impact factor: 4.506

8.  Fast calculation of nanodosimetric quantities in treatment planning of proton and ion therapy.

Authors:  José Ramos-Méndez; Lucas N Burigo; Reinhard Schulte; Cynthia Chuang; Bruce Faddegon
Journal:  Phys Med Biol       Date:  2018-11-28       Impact factor: 3.609

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.