Literature DB >> 27997375

Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR.

Yoann Petibon1, Nicolas J Guehl, Timothy G Reese, Behzad Ebrahimi, Marc D Normandin, Timothy M Shoup, Nathaniel M Alpert, Georges El Fakhri, Jinsong Ouyang.   

Abstract

PET is an established modality for myocardial perfusion imaging (MPI) which enables quantification of absolute myocardial blood flow (MBF) using dynamic imaging and kinetic modeling. However, heart motion and partial volume effects (PVE) significantly limit the spatial resolution and quantitative accuracy of PET MPI. Simultaneous PET-MR offers a solution to the motion problem in PET by enabling MR-based motion correction of PET data. The aim of this study was to develop a motion and PVE correction methodology for PET MPI using simultaneous PET-MR, and to assess its impact on both static and dynamic PET MPI using 18F-Flurpiridaz, a novel 18F-labeled perfusion tracer. Two dynamic 18F-Flurpiridaz MPI scans were performed on healthy pigs using a PET-MR scanner. Cardiac motion was tracked using a dedicated tagged-MRI (tMR) sequence. Motion fields were estimated using non-rigid registration of tMR images and used to calculate motion-dependent attenuation maps. Motion correction of PET data was achieved by incorporating tMR-based motion fields and motion-dependent attenuation coefficients into image reconstruction. Dynamic and static PET datasets were created for each scan. Each dataset was reconstructed as (i) Ungated, (ii) Gated (end-diastolic phase), and (iii) Motion-Corrected (MoCo), each without and with point spread function (PSF) modeling for PVE correction. Myocardium-to-blood concentration ratios (MBR) and apparent wall thickness were calculated to assess image quality for static MPI. For dynamic MPI, segment- and voxel-wise MBF values were estimated by non-linear fitting of a 2-tissue compartment model to tissue time-activity-curves. MoCo and Gating respectively decreased mean apparent wall thickness by 15.1% and 14.4% and increased MBR by 20.3% and 13.6% compared to Ungated images (P  <  0.01). Combined motion and PSF correction (MoCo-PSF) yielded 30.9% (15.7%) lower wall thickness and 82.2% (20.5%) higher MBR compared to Ungated data reconstructed without (with) PSF modeling (P  <  0.01). For dynamic PET, mean MBF across all segments were comparable for MoCo (0.72  ±  0.21 ml/min/ml) and Gating (0.69  ±  0.18 ml/min/ml). Ungated data yielded significantly lower mean MBF (0.59  ±  0.16 ml/min/ml). Mean MBF for MoCo-PSF was 0.80  ±  0.22 ml/min/ml, which was 37.9% (25.0%) higher than that obtained from Ungated data without (with) PSF correction (P  <  0.01). The developed methodology holds promise to improve the image quality and sensitivity of PET MPI studies performed using PET-MR.

Entities:  

Mesh:

Year:  2016        PMID: 27997375      PMCID: PMC5241952          DOI: 10.1088/1361-6560/aa5087

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  47 in total

Review 1.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.

Authors:  Manuel D Cerqueira; Neil J Weissman; Vasken Dilsizian; Alice K Jacobs; Sanjiv Kaul; Warren K Laskey; Dudley J Pennell; John A Rumberger; Thomas Ryan; Mario S Verani
Journal:  J Nucl Cardiol       Date:  2002 Mar-Apr       Impact factor: 5.952

Review 2.  Quantification of myocardial blood flow and flow reserve: Technical aspects.

Authors:  Ran Klein; Rob S B Beanlands; Robert A deKemp
Journal:  J Nucl Cardiol       Date:  2010-08       Impact factor: 5.952

3.  Model-based image reconstruction for four-dimensional PET.

Authors:  Tianfang Li; Brian Thorndyke; Eduard Schreibmann; Yong Yang; Lei Xing
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

4.  Single-scan rest∕stress imaging (18)F-labeled flow tracers.

Authors:  Nathaniel Alpert; Yu-Hua Dean Fang; Georges El Fakhri
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

5.  Fractal nature of regional myocardial blood flow heterogeneity.

Authors:  J B Bassingthwaighte; R B King; S A Roger
Journal:  Circ Res       Date:  1989-09       Impact factor: 17.367

6.  Three-dimensional myocardial deformations: calculation with displacement field fitting to tagged MR images.

Authors:  W G O'Dell; C C Moore; W C Hunter; E A Zerhouni; E R McVeigh
Journal:  Radiology       Date:  1995-06       Impact factor: 11.105

7.  Motion Artifacts in Oncological and Cardiac PET Imaging.

Authors:  Julia Dinges; Stephan G Nekolla; Ralph A Bundschuh
Journal:  PET Clin       Date:  2012-11-26

8.  A simple regularizer for B-spline nonrigid image registration that encourages local invertibility.

Authors:  Se Young Chun; Jeffrey A Fessler
Journal:  IEEE J Sel Top Signal Process       Date:  2009-02-01       Impact factor: 6.856

9.  Heterogeneity of resting and hyperemic myocardial blood flow in healthy humans.

Authors:  P Chareonthaitawee; P A Kaufmann; O Rimoldi; P G Camici
Journal:  Cardiovasc Res       Date:  2001-04       Impact factor: 10.787

10.  Phase II safety and clinical comparison with single-photon emission computed tomography myocardial perfusion imaging for detection of coronary artery disease: flurpiridaz F 18 positron emission tomography.

Authors:  Daniel S Berman; Jamshid Maddahi; B K Tamarappoo; Johannes Czernin; Raymond Taillefer; James E Udelson; C Michael Gibson; Marybeth Devine; Joel Lazewatsky; Gajanan Bhat; Dana Washburn
Journal:  J Am Coll Cardiol       Date:  2012-12-19       Impact factor: 24.094

View more
  12 in total

1.  MR-based PET attenuation correction using a combined ultrashort echo time/multi-echo Dixon acquisition.

Authors:  Paul Kyu Han; Debra E Horng; Kuang Gong; Yoann Petibon; Kyungsang Kim; Quanzheng Li; Keith A Johnson; Georges El Fakhri; Jinsong Ouyang; Chao Ma
Journal:  Med Phys       Date:  2020-05-11       Impact factor: 4.071

Review 2.  Clinical use of cardiac PET/MRI: current state-of-the-art and potential future applications.

Authors:  Patrick Krumm; Stefanie Mangold; Sergios Gatidis; Konstantin Nikolaou; Felix Nensa; Fabian Bamberg; Christian la Fougère
Journal:  Jpn J Radiol       Date:  2018-03-10       Impact factor: 2.374

3.  MR-based cardiac and respiratory motion correction of PET: application to static and dynamic cardiac 18F-FDG imaging.

Authors:  Y Petibon; T Sun; P K Han; C Ma; G El Fakhri; J Ouyang
Journal:  Phys Med Biol       Date:  2019-10-04       Impact factor: 3.609

4.  Performance study of a radio-frequency field-penetrable PET insert for simultaneous PET/MRI.

Authors:  Chen-Ming Chang; Brian J Lee; Alexander M Grant; Andrew N Groll; Craig S Levin
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2018-07-03

5.  Body motion detection and correction in cardiac PET: Phantom and human studies.

Authors:  Tao Sun; Yoann Petibon; Paul K Han; Chao Ma; Sally J W Kim; Nathaniel M Alpert; Georges El Fakhri; Jinsong Ouyang
Journal:  Med Phys       Date:  2019-10-08       Impact factor: 4.071

6.  Correction of respiratory and cardiac motion in cardiac PET/MR using MR-based motion modeling.

Authors:  Philip M Robson; MariaGiovanna Trivieri; Nicolas A Karakatsanis; Maria Padilla; Ronan Abgral; Marc R Dweck; Jason C Kovacic; Zahi A Fayad
Journal:  Phys Med Biol       Date:  2018-11-14       Impact factor: 3.609

7.  Motion correction for PET data using subspace-based real-time MR imaging in simultaneous PET/MR.

Authors:  Thibault Marin; Yanis Djebra; Paul K Han; Yanis Chemli; Isabelle Bloch; Georges El Fakhri; Jinsong Ouyang; Yoann Petibon; Chao Ma
Journal:  Phys Med Biol       Date:  2020-12-02       Impact factor: 3.609

8.  Evaluation of synergistic image registration for motion-corrected coronary NaF-PET-MR.

Authors:  Johannes Mayer; Yining Jin; Thomas-Heinrich Wurster; Marcus R Makowski; Christoph Kolbitsch
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2021-05-10       Impact factor: 4.226

Review 9.  Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging.

Authors:  Irene Polycarpou; Georgios Soultanidis; Charalampos Tsoumpas
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2021-07-05       Impact factor: 4.226

10.  The effect of high count rates on cardiac perfusion quantification in a simultaneous PET-MR system using a cardiac perfusion phantom.

Authors:  Jim O' Doherty; Zacharias Chalampalakis; Paul Schleyer; Muhummad Sohaib Nazir; Amedeo Chiribiri; Paul K Marsden
Journal:  EJNMMI Phys       Date:  2017-12-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.