Literature DB >> 27903601

Performance Evaluation of Allplex Respiratory Panels 1, 2, and 3 for Detection of Respiratory Viruses and Influenza A Virus Subtypes.

Hee Jae Huh1, Ji-Youn Kim2, Hyeon Jeong Kwon2, Sun Ae Yun2, Myoung-Keun Lee1, Nam Yong Lee1, Jong-Won Kim1, Chang-Seok Ki3.   

Abstract

The Allplex respiratory panels 1, 2, and 3 (Allplex) comprise a one-step real-time reverse transcription-PCR assay for the detection of respiratory viruses (RVs) and influenza A subtypes based on multiple detection temperature (MuDT) technology. The performance of the Allplex assay was compared with those of the AdvanSure RV real-time PCR kit (AdvanSure) and the PowerChek pandemic H1N1/H3N2/H5N1 real-time PCR kit (PowerChek) using 417 clinical respiratory specimens. In comparison with the AdvanSure assay for RV detection by each virus, the ranges of positive percent agreement, negative percent agreement, and kappa values with the Allplex assay were 82.8 to 100%, 95.5 to 100%, and 0.85 to 1.00, respectively. For influenza A virus (INF A) subtyping, the kappa values between the Allplex and PowerChek assays were 0.67 and 1.00 for the INF A H1N1-pdm09 and H3 subtypes, respectively. Uniplex PCR and sequencing for samples with discrepant results demonstrated that the majority of results were concordant with those from the Allplex assay. When testing 24 samples, the turnaround and hands-on time required to perform the Allplex assay were 4 h 15 min and 15 min, respectively. In conclusion, the Allplex assay produced results comparable to those from the AdvanSure and PowerChek assays.
Copyright © 2017 American Society for Microbiology.

Entities:  

Keywords:  Republic of Korea; multiplex real-time PCR; respiratory virus; validation

Mesh:

Year:  2016        PMID: 27903601      PMCID: PMC5277517          DOI: 10.1128/JCM.02045-16

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  20 in total

1.  Comparison of the Biofire FilmArray RP, Genmark eSensor RVP, Luminex xTAG RVPv1, and Luminex xTAG RVP fast multiplex assays for detection of respiratory viruses.

Authors:  Elena B Popowitch; Stacey S O'Neill; Melissa B Miller
Journal:  J Clin Microbiol       Date:  2013-03-13       Impact factor: 5.948

2.  Effect of rapid viral diagnosis on the management of children hospitalized with lower respiratory tract infection.

Authors:  P M Adcock; G G Stout; M A Hauck; G S Marshall
Journal:  Pediatr Infect Dis J       Date:  1997-09       Impact factor: 2.129

3.  Cost analysis of multiplex PCR testing for diagnosing respiratory virus infections.

Authors:  James B Mahony; Gord Blackhouse; Jesse Babwah; Marek Smieja; Sonya Buracond; Sylvia Chong; William Ciccotelli; Tim O'Shea; Daifallah Alnakhli; May Griffiths-Turner; Ron Goeree
Journal:  J Clin Microbiol       Date:  2009-07-01       Impact factor: 5.948

4.  Clinical Evaluation of the New High-Throughput Luminex NxTAG Respiratory Pathogen Panel Assay for Multiplex Respiratory Pathogen Detection.

Authors:  Jonathan H K Chen; Ho-Yin Lam; Cyril C Y Yip; Sally C Y Wong; Jasper F W Chan; Edmond S K Ma; Vincent C C Cheng; Bone S F Tang; Kwok-Yung Yuen
Journal:  J Clin Microbiol       Date:  2016-04-27       Impact factor: 5.948

5.  BioFire FilmArray Respiratory Panel for Detection of Enterovirus D68.

Authors:  Dena R Shibib; Scott M Matushek; Kathleen G Beavis; Susan H Gawel; Angella Charnot-Katsikas
Journal:  J Clin Microbiol       Date:  2015-11-25       Impact factor: 5.948

6.  FilmArray, an automated nested multiplex PCR system for multi-pathogen detection: development and application to respiratory tract infection.

Authors:  Mark A Poritz; Anne J Blaschke; Carrie L Byington; Lindsay Meyers; Kody Nilsson; David E Jones; Stephanie A Thatcher; Thomas Robbins; Beth Lingenfelter; Elizabeth Amiott; Amy Herbener; Judy Daly; Steven F Dobrowolski; David H-F Teng; Kirk M Ririe
Journal:  PLoS One       Date:  2011-10-19       Impact factor: 3.240

7.  Single-channel multiplexing without melting curve analysis in real-time PCR.

Authors:  Young-Jo Lee; Daeyoung Kim; Kihoon Lee; Jong-Yoon Chun
Journal:  Sci Rep       Date:  2014-12-11       Impact factor: 4.379

8.  Comparison of the AdvanSure™ real-time RT-PCR and Seeplex(®) RV12 ACE assay for the detection of respiratory viruses.

Authors:  Yu Jung Jung; Hyeon Jeong Kwon; Hee Jae Huh; Chang-Seok Ki; Nam Yong Lee; Jong-Won Kim
Journal:  J Virol Methods       Date:  2015-08-13       Impact factor: 2.014

Review 9.  Multiplex PCR and emerging technologies for the detection of respiratory pathogens.

Authors:  Angela M Caliendo
Journal:  Clin Infect Dis       Date:  2011-05       Impact factor: 9.079

10.  Comparison of FilmArray Respiratory Panel and laboratory-developed real-time reverse transcription-polymerase chain reaction assays for respiratory virus detection.

Authors:  Christian Renaud; Janet Crowley; Keith R Jerome; Jane Kuypers
Journal:  Diagn Microbiol Infect Dis       Date:  2012-09-13       Impact factor: 2.803

View more
  9 in total

1.  Impact of Rapid Molecular Diagnostic Testing of Respiratory Viruses on Outcomes of Adults Hospitalized with Respiratory Illness: a Multicenter Quasi-experimental Study.

Authors:  Nasir Wabe; Ling Li; Robert Lindeman; Ruth Yimsung; Maria R Dahm; Susan McLennan; Kate Clezy; Johanna I Westbrook; Andrew Georgiou
Journal:  J Clin Microbiol       Date:  2019-03-28       Impact factor: 5.948

2.  Coinfections with Respiratory Pathogens among COVID-19 Patients in Korea.

Authors:  Kyoung Ho Roh; Yu Kyung Kim; Shin-Woo Kim; Eun-Rim Kang; Yong-Jin Yang; Sun-Kyung Jung; Sun-Hwa Lee; Nackmoon Sung
Journal:  Can J Infect Dis Med Microbiol       Date:  2021-05-12       Impact factor: 2.471

3.  A Simple Scoring System to Differentiate Bacterial from Viral Infections in Acute Exacerbations of COPD Requiring Hospitalization.

Authors:  Agustín Ruiz-González; Eduardo Sáez-Huerta; Montserrat Martínez-Alonso; Albert Bernet-Sánchez; José M Porcel
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2022-04-08

4.  Development of a multiplex real-time PCR assay for the simultaneous detection of four bacterial pathogens causing pneumonia.

Authors:  Ho Jae Lim; Eun-Rim Kang; Min Young Park; Bo Kyung Kim; Min Jin Kim; Sunkyung Jung; Kyoung Ho Roh; Nackmoon Sung; Jae-Hyun Yang; Min-Woo Lee; Sun-Hwa Lee; Yong-Jin Yang
Journal:  PLoS One       Date:  2021-06-17       Impact factor: 3.240

5.  Evaluation of Allplex Respiratory Panel 1/2/3 Multiplex Real-Time PCR Assays for the Detection of Respiratory Viruses with Influenza A Virus subtyping.

Authors:  Jaehyeon Lee; Hye Soo Lee; Yong Gon Cho; Sam Im Choi; Dal Sik Kim
Journal:  Ann Lab Med       Date:  2018-01       Impact factor: 3.464

6.  Viruses of Respiratory Tract: an Observational Retrospective Study on Hospitalized Patients in Rome, Italy.

Authors:  Marco Ciotti; Massimo Maurici; Viviana Santoro; Luigi Coppola; Loredana Sarmati; Gerardo De Carolis; Patrizia De Filippis; Francesca Pica
Journal:  Microorganisms       Date:  2020-04-01

7.  Comparison of the Panther Fusion and Allplex assays for the detection of respiratory viruses in clinical samples.

Authors:  Lola Folgueira; Noelia Moral; Consuelo Pascual; Rafael Delgado
Journal:  PLoS One       Date:  2019-12-27       Impact factor: 3.240

8.  Comparative Evaluation of Allplex Respiratory Panels 1, 2, 3, and BioFire FilmArray Respiratory Panel for the Detection of Respiratory Infections.

Authors:  Harshad Lade; Jung-Min Kim; Yousun Chung; Minje Han; Eun-Kyung Mo; Jae-Seok Kim
Journal:  Diagnostics (Basel)       Date:  2021-12-22

9.  Cepheid Xpert® Flu/RSV and Seegene Allplex RP1 show high diagnostic agreement for the detection of influenza A/B and respiratory syncytial viruses in clinical practice.

Authors:  Nasir Wabe; Robert Lindeman; Jeffrey J Post; William Rawlinson; Melissa Miao; Johanna I Westbrook; Andrew Georgiou
Journal:  Influenza Other Respir Viruses       Date:  2020-08-20       Impact factor: 5.606

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.