Literature DB >> 27774656

Improving the robustness of pseudo-continuous arterial spin labeling to off-resonance and pulsatile flow velocity.

Li Zhao1, Marta Vidorreta2,3, Salil Soman1, John A Detre2,3, David C Alsop1.   

Abstract

PURPOSE: To improve pseudo-continuous arterial spin labeling (PCASL) robustness to off-resonance and pulsatile blood flow velocity.
METHODS: Bloch equations were solved to evaluate the effect of labeling parameters in a pulsatile flow model for a range of off-resonance. Experimental confirmation was achieved in volunteers using linear phase increase between labeling pulses to approximate off-resonance errors. We first assessed the location of the labeling plane in four volunteers. Next, we explored a range of parameters-including balanced and unbalanced gradients-in five more volunteers at an optimal labeling plane location.
RESULTS: Simulations demonstrated that 1) high velocities are vulnerable to off-resonance, 2) unbalanced PCASL outperforms balanced PCASL, 3) increased B1 and low average gradient improve the labeling efficiency for high-velocity flow, and 4) a low ratio of selective to average gradient improves off-resonance robustness. A good agreement between theory and experiment was observed.
CONCLUSION: The robustness of PCASL can be increased by selecting an unbalanced scheme with a low average gradient (0.5 mT/m), a low ratio (7×) of selective to average gradients, and the highest feasible B1 (1.8 μT). Placing the labeling plane above the carotid bifurcation and below the V3 segment, usually between the second and third vertebrae, yielded robust results. Magn Reson Med 78:1342-1351, 2017.
© 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  balanced PCASL; labeling efficiency; off-resonance; pseudo-continuous arterial spin labeling (PCASL); unbalanced PCASL

Mesh:

Year:  2016        PMID: 27774656      PMCID: PMC5848499          DOI: 10.1002/mrm.26513

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  24 in total

1.  Characterization of common carotid artery blood-flow waveforms in normal human subjects.

Authors:  D W Holdsworth; C J Norley; R Frayne; D A Steinman; B K Rutt
Journal:  Physiol Meas       Date:  1999-08       Impact factor: 2.833

2.  Multiphase pseudocontinuous arterial spin labeling (MP-PCASL) for robust quantification of cerebral blood flow.

Authors:  Youngkyoo Jung; Eric C Wong; Thomas T Liu
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

3.  Velocity-selective arterial spin labeling.

Authors:  Eric C Wong; Matthew Cronin; Wen-Chau Wu; Ben Inglis; Lawrence R Frank; Thomas T Liu
Journal:  Magn Reson Med       Date:  2006-06       Impact factor: 4.668

4.  A theoretical and experimental investigation of the tagging efficiency of pseudocontinuous arterial spin labeling.

Authors:  Wen-Chau Wu; María Fernández-Seara; John A Detre; Felix W Wehrli; Jiongjiong Wang
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

5.  B0 field inhomogeneity considerations in pseudo-continuous arterial spin labeling (pCASL): effects on tagging efficiency and correction strategy.

Authors:  Hesamoddin Jahanian; Douglas C Noll; Luis Hernandez-Garcia
Journal:  NMR Biomed       Date:  2011-03-08       Impact factor: 4.044

6.  Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling.

Authors:  E C Wong; R B Buxton; L R Frank
Journal:  NMR Biomed       Date:  1997 Jun-Aug       Impact factor: 4.044

7.  Perfusion imaging by a flow-sensitive alternating inversion recovery (FAIR) technique: application to functional brain imaging.

Authors:  S G Kim; N V Tsekos
Journal:  Magn Reson Med       Date:  1997-03       Impact factor: 4.668

8.  Comparison of non-invasive MRI measurements of cerebral blood flow in a large multisite cohort.

Authors:  Sudipto Dolui; Ze Wang; Danny J J Wang; Raghav Mattay; Mack Finkel; Mark Elliott; Lisa Desiderio; Ben Inglis; Bryon Mueller; Randall B Stafford; Lenore J Launer; David R Jacobs; R Nick Bryan; John A Detre
Journal:  J Cereb Blood Flow Metab       Date:  2016-05-03       Impact factor: 6.200

9.  Estimation of labeling efficiency in pseudocontinuous arterial spin labeling.

Authors:  Sina Aslan; Feng Xu; Peiying L Wang; Jinsoo Uh; Uma S Yezhuvath; Matthias van Osch; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2010-03       Impact factor: 4.668

10.  Reduced resolution transit delay prescan for quantitative continuous arterial spin labeling perfusion imaging.

Authors:  Weiying Dai; Philip M Robson; Ajit Shankaranarayanan; David C Alsop
Journal:  Magn Reson Med       Date:  2011-11-14       Impact factor: 4.668

View more
  20 in total

1.  Controlling T2 blurring in 3D RARE arterial spin labeling acquisition through optimal combination of variable flip angles and k-space filtering.

Authors:  Li Zhao; Ching-Di Chang; David C Alsop
Journal:  Magn Reson Med       Date:  2018-02-09       Impact factor: 4.668

2.  Improved velocity-selective-inversion arterial spin labeling for cerebral blood flow mapping with 3D acquisition.

Authors:  Dapeng Liu; Feng Xu; Wenbo Li; Peter C van Zijl; Doris D Lin; Qin Qin
Journal:  Magn Reson Med       Date:  2020-05-13       Impact factor: 4.668

3.  Pseudo continuous arterial spin labeling quantification in anemic subjects with hyperemic cerebral blood flow.

Authors:  Adam Bush; Yaqiong Chai; So Young Choi; Lena Vaclavu; Scott Holland; Aart Nederveen; Thomas Coates; John Wood
Journal:  Magn Reson Imaging       Date:  2017-12-09       Impact factor: 2.546

4.  Human Placenta Blood Flow During Early Gestation With Pseudocontinuous Arterial Spin Labeling MRI.

Authors:  Dapeng Liu; Xingfeng Shao; Alibek Danyalov; Teresa Chanlaw; Rinat Masamed; Danny J J Wang; Carla Janzen; Sherin U Devaskar; Kyunghyun Sung
Journal:  J Magn Reson Imaging       Date:  2019-11-04       Impact factor: 4.813

5.  Optimization of pseudo-continuous arterial spin labeling using off-resonance compensation strategies at 7T.

Authors:  Gaël Saïb; Alan P Koretsky; S Lalith Talagala
Journal:  Magn Reson Med       Date:  2021-11-14       Impact factor: 3.737

6.  Cerebrovascular reactivity measurements using simultaneous 15O-water PET and ASL MRI: Impacts of arterial transit time, labeling efficiency, and hematocrit.

Authors:  Moss Y Zhao; Audrey P Fan; David Yen-Ting Chen; Magdalena J Sokolska; Jia Guo; Yosuke Ishii; David D Shin; Mohammad Mehdi Khalighi; Dawn Holley; Kim Halbert; Andrea Otte; Brittney Williams; Taghi Rostami; Jun-Hyung Park; Bin Shen; Greg Zaharchuk
Journal:  Neuroimage       Date:  2021-03-11       Impact factor: 6.556

7.  Spatial dependency and the role of local susceptibility for velocity selective arterial spin labeling (VS-ASL) relative tagging efficiency using accelerated 3D radial sampling with a BIR-8 preparation.

Authors:  James H Holmes; Mu-Lan Jen; Laura B Eisenmenger; Tilman Schubert; Patrick A Turski; Kevin M Johnson
Journal:  Magn Reson Med       Date:  2021-02-21       Impact factor: 3.737

8.  Noncontrast assessment of blood-brain barrier permeability to water: Shorter acquisition, test-retest reproducibility, and comparison with contrast-based method.

Authors:  Zixuan Lin; Dengrong Jiang; Dapeng Liu; Yang Li; Jinsoo Uh; Xirui Hou; Jay J Pillai; Qin Qin; Yulin Ge; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2021-02-08       Impact factor: 3.737

9.  Consensus-based technical recommendations for clinical translation of renal ASL MRI.

Authors:  Fabio Nery; Charlotte E Buchanan; Anita A Harteveld; Aghogho Odudu; Octavia Bane; Eleanor F Cox; Katja Derlin; H Michael Gach; Xavier Golay; Marcel Gutberlet; Christoffer Laustsen; Alexandra Ljimani; Ananth J Madhuranthakam; Ivan Pedrosa; Pottumarthi V Prasad; Philip M Robson; Kanishka Sharma; Steven Sourbron; Manuel Taso; David L Thomas; Danny J J Wang; Jeff L Zhang; David C Alsop; Sean B Fain; Susan T Francis; María A Fernández-Seara
Journal:  MAGMA       Date:  2019-12-12       Impact factor: 2.533

10.  Implementation and validation of ASL perfusion measurements for population imaging.

Authors:  Esther A H Warnert; Rebecca M E Steketee; Meike W Vernooij; M Arfan Ikram; Mika Vogel; Juan-Antonio Hernandez Tamames; Gyula Kotek
Journal:  Magn Reson Med       Date:  2020-04-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.