Literature DB >> 9430354

Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling.

E C Wong1, R B Buxton, L R Frank.   

Abstract

We describe here experimental considerations in the implementation of quantitative perfusion imaging techniques for functional MRI using pulsed arterial spin labeling. Three tagging techniques: EPISTAR, PICORE, and FAIR are found to give very similar perfusion results despite large differences in static tissue contrast. Two major sources of systematic error in the perfusion measurement are identified: the transit delay from the tagging region to the imaging slice; and the inclusion of intravascular tagged signal. A modified technique called QUIPSS II is described that decreases sensitivity to these effects by explicitly controlling the time width of the tag bolus and imaging after the bolus is entirely deposited into the slice. With appropriate saturation pulses the pulse sequence can be arranged so as to allow for simultaneous collection of perfusion and BOLD data that can be cleanly separated. Such perfusion and BOLD signals reveal differences in spatial location and dynamics that may be useful both for functional brain mapping and for study of the BOLD contrast mechanism. The implementation of multislice perfusion imaging introduces additional complications, primarily in the elimination of signal from static tissue. In pulsed ASL, this appears to be related to the slice profile of the inversion tag pulse in the presence of relaxation, rather than magnetization transfer effects as in continuous arterial spin labeling, and can be alleviated with careful adjustment of inversion pulse parameters.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9430354     DOI: 10.1002/(sici)1099-1492(199706/08)10:4/5<237::aid-nbm475>3.0.co;2-x

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  192 in total

1.  Nonlinear temporal dynamics of the cerebral blood flow response.

Authors:  K L Miller; W M Luh; T T Liu; A Martinez; T Obata; E C Wong; L R Frank; R B Buxton
Journal:  Hum Brain Mapp       Date:  2001-05       Impact factor: 5.038

2.  Whole-brain cerebral blood flow mapping using 3D echo planar imaging and pulsed arterial tagging.

Authors:  Neville D Gai; S Lalith Talagala; John A Butman
Journal:  J Magn Reson Imaging       Date:  2011-02       Impact factor: 4.813

3.  Confounding effect of large vessels on MR perfusion images analyzed with independent component analysis.

Authors:  Timothy J Carroll; Victor M Haughton; Howard A Rowley; Dietmar Cordes
Journal:  AJNR Am J Neuroradiol       Date:  2002 Jun-Jul       Impact factor: 3.825

4.  Correlation between flow-sensitive alternating inversion recovery perfusion imaging with different inversion times and cerebral flow reserve evaluated by single-photon-emission computed tomography.

Authors:  Masafumi Harada; Masaaki Uno; Kazuhide Yoneda; Ayuko Hori; Hiromu Nishitani; Tsuyoshi Matsuda
Journal:  Neuroradiology       Date:  2004-06-19       Impact factor: 2.804

5.  The response to rapid infusion of fentanyl in the human brain measured using pulsed arterial spin labelling.

Authors:  Fernando O Zelaya; Evangelos Zois; Christopher Muller-Pollard; David J Lythgoe; Sarah Lee; Caroline Andrews; Trevor Smart; Patricia Conrod; William Vennart; Steven C R Williams; Mitul A Mehta; Laurence J Reed
Journal:  MAGMA       Date:  2011-11-24       Impact factor: 2.310

6.  Comparison of relative cerebral blood flow maps using pseudo-continuous arterial spin labeling and single photon emission computed tomography.

Authors:  Peiying Liu; Jinsoo Uh; Michael D Devous; Bryon Adinoff; Hanzhang Lu
Journal:  NMR Biomed       Date:  2011-12-02       Impact factor: 4.044

7.  Localization of the hand motor area by arterial spin labeling and blood oxygen level-dependent functional magnetic resonance imaging.

Authors:  Marco A F Pimentel; Pedro Vilela; Inês Sousa; Patrícia Figueiredo
Journal:  Hum Brain Mapp       Date:  2011-11-28       Impact factor: 5.038

8.  Venous oxygenation mapping using velocity-selective excitation and arterial nulling.

Authors:  Jia Guo; Eric C Wong
Journal:  Magn Reson Med       Date:  2012-01-31       Impact factor: 4.668

Review 9.  Current trends and challenges in MRI acquisitions to investigate brain function.

Authors:  Bradley P Sutton; Cheng Ouyang; Dimitrios C Karampinos; Gregory A Miller
Journal:  Int J Psychophysiol       Date:  2009-02-21       Impact factor: 2.997

10.  Structural Correlation-based Outlier Rejection (SCORE) algorithm for arterial spin labeling time series.

Authors:  Sudipto Dolui; Ze Wang; Russell T Shinohara; David A Wolk; John A Detre
Journal:  J Magn Reson Imaging       Date:  2016-08-29       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.