Literature DB >> 20578056

Multiphase pseudocontinuous arterial spin labeling (MP-PCASL) for robust quantification of cerebral blood flow.

Youngkyoo Jung1, Eric C Wong, Thomas T Liu.   

Abstract

Pseudocontinuous arterial spin labeling (PCASL) has been demonstrated to provide the sensitivity of the continuous arterial spin labeling method while overcoming many of the limitations of that method. Because the specification of the phases in the radiofrequency pulse train in PCASL defines the tag and control conditions of the flowing arterial blood, its tagging efficiency is sensitive to factors, such as off-resonance fields, that induce phase mismatches between the radiofrequency pulses and the flowing spins. As a result, the quantitative estimation of cerebral blood flow with PCASL can exhibit a significant amount of error when these factors are not taken into account. In this paper, the sources of the tagging efficiency loss are characterized and a novel PCASL method that utilizes multiple phase offsets is proposed to reduce the tagging efficiency loss in PCASL. Simulations are performed to evaluate the feasibility and the performance of the proposed method. Quantitative estimates of cerebral blood flow obtained with multiple phase offset PCASL are compared to estimates obtained with conventional PCASL and pulsed arterial spin labeling. Our results show that multiple phase offset PCASL provides robust cerebral blood flow quantification while retaining much of the sensitivity advantage of PCASL. 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20578056     DOI: 10.1002/mrm.22465

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  51 in total

1.  Blind detection of vascular sources and territories using random vessel encoded arterial spin labeling.

Authors:  Eric C Wong; Jia Guo
Journal:  MAGMA       Date:  2012-01-10       Impact factor: 2.310

2.  Noncontrast-enhanced three-dimensional (3D) intracranial MR angiography using pseudocontinuous arterial spin labeling and accelerated 3D radial acquisition.

Authors:  Huimin Wu; Walter F Block; Patrick A Turski; Charles A Mistretta; Kevin M Johnson
Journal:  Magn Reson Med       Date:  2012-04-24       Impact factor: 4.668

3.  Potentials and challenges for arterial spin labeling in pharmacological magnetic resonance imaging.

Authors:  Danny J J Wang; Yufen Chen; María A Fernández-Seara; John A Detre
Journal:  J Pharmacol Exp Ther       Date:  2011-02-11       Impact factor: 4.030

4.  Real-time functional MRI using pseudo-continuous arterial spin labeling.

Authors:  Luis Hernandez-Garcia; Hesamoddin Jahanian; Mark K Greenwald; Jon-Kar Zubieta; Scott J Peltier
Journal:  Magn Reson Med       Date:  2011-03-28       Impact factor: 4.668

Review 5.  Biomarkers, designs, and interpretations of resting-state fMRI in translational pharmacological research: A review of state-of-the-Art, challenges, and opportunities for studying brain chemistry.

Authors:  Najmeh Khalili-Mahani; Serge A R B Rombouts; Matthias J P van Osch; Eugene P Duff; Felix Carbonell; Lisa D Nickerson; Lino Becerra; Albert Dahan; Alan C Evans; Jean-Paul Soucy; Richard Wise; Alex P Zijdenbos; Joop M van Gerven
Journal:  Hum Brain Mapp       Date:  2017-02-01       Impact factor: 5.038

Review 6.  CEST, ASL, and magnetization transfer contrast: How similar pulse sequences detect different phenomena.

Authors:  Linda Knutsson; Jiadi Xu; André Ahlgren; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2018-05-30       Impact factor: 4.668

7.  Comparison of non-invasive MRI measurements of cerebral blood flow in a large multisite cohort.

Authors:  Sudipto Dolui; Ze Wang; Danny J J Wang; Raghav Mattay; Mack Finkel; Mark Elliott; Lisa Desiderio; Ben Inglis; Bryon Mueller; Randall B Stafford; Lenore J Launer; David R Jacobs; R Nick Bryan; John A Detre
Journal:  J Cereb Blood Flow Metab       Date:  2016-05-03       Impact factor: 6.200

8.  Test-retest reliability of arterial spin labeling with common labeling strategies.

Authors:  Yufen Chen; Danny J J Wang; John A Detre
Journal:  J Magn Reson Imaging       Date:  2011-04       Impact factor: 4.813

9.  An Actively Decoupled Dual Transceiver Coil System for Continuous ASL at 7 T.

Authors:  Randall B Stafford; Myung-Kyun Woo; Se-Hong Oh; Sudipto Dolui; Tiejun Zhao; Young-Bo Kim; John A Detre; Zang-Hee Cho; Jongho Lee
Journal:  Int J Imaging Syst Technol       Date:  2016-06-16       Impact factor: 2.000

10.  Anti-correlated networks, global signal regression, and the effects of caffeine in resting-state functional MRI.

Authors:  Chi Wah Wong; Valur Olafsson; Omer Tal; Thomas T Liu
Journal:  Neuroimage       Date:  2012-06-26       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.